CAD system for full-digital mammography and its evaluation

被引:6
|
作者
Kobatake, H
Okuno, K
Murakami, M
Ishida, M
Takeo, H
Nawano, S
机构
来源
IMAGE PROCESSING - MEDICAL IMAGING 1997, PTS 1 AND 2 | 1997年 / 3034卷
关键词
breast cancer; mammography; CAD; malignant tumors; microcalcifications; iris filter; morphological processing;
D O I
10.1117/12.274161
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The purpose of this study is to develop a clinical intelligent workstation for computer-aided diagnosis (CAD) of breast cancer using fall digital mammography. It consists of a clinical workstation and Fuji Computed Radiography 9000 System. New image processing methods to extract tumor masses and clustered microcalcifications have been developed and implemented in the CAD system. A new filter called Iris Filter has been developed to detect tumor candidates. It realizes reliable detection of tumor candidates regardless of their sizes and their contrast against their background on mammograms. And a new method based on mathematical morphology has been developed to detect microcalcifications. It is adaptive to the imaging conditions of mammograms. One thousand, two hundred and twelve CR images, which include 240 malignant tumors, were used to test the performance of the system. The sensitivity for malignant tumors was 90.5% and the average number of false positives per image were only 1.3. The true positive detection rate for clustered microcalcifications was 89.2% and the average number of false positives per image were 0.36. The high true positive rates and the low false positive detection characterize the proposed full-digital CAD system, which shows the possibility of practical application of computer aided diagnosis of breast cancer.
引用
收藏
页码:745 / 752
页数:8
相关论文
共 50 条
  • [21] Full-Digital Customized Meshes in Guided Bone Regeneration Procedures: A Scoping Review
    Scribante, Andrea
    Ghizzoni, Martina
    Pellegrini, Matteo
    Pulicari, Federica
    Manfredini, Mattia
    Poli, Pier Paolo
    Maiorana, Carlo
    Spadari, Francesco
    PROSTHESIS, 2023, 5 (02): : 480 - 495
  • [22] Radiation Exposure of Contrast-Enhanced Spectral Mammography Compared With Full-Field Digital Mammography
    Jeukens, Cecile R. L. P. N.
    Lalji, Ulrich C.
    Meijer, Eduard
    Bakija, Betina
    Theunissen, Robin
    Wildberger, Joachim E.
    Lobbes, Marc B. I.
    INVESTIGATIVE RADIOLOGY, 2014, 49 (10) : 659 - 665
  • [23] Full-field digital mammography on LCD versus CRT monitors
    Zuley, Margarita L.
    Willison, Kathleen M.
    Bonaccio, Ermelinda
    Miller, David P.
    Leong, David L.
    Seifert, Posy J.
    Somerville, Patricia
    Destounis, Stamatia
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (06) : 1492 - 1498
  • [24] Sensitivity of a Direct Computer-aided Detection System in Full-field Digital Mammography for Detection of Microcalcifications Not Associated with Mass or Architectural Distortion
    Scaranelo, Anabel M.
    Crystal, Pavel
    Bukhanov, Karina
    Helbich, Thomas H.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2010, 61 (03): : 162 - 169
  • [25] Digital zoom of the full-field digital mammogram versus magnification mammography: a systematic review
    Oynes, Mona
    Strom, Bergliot
    Tveito, Bente
    Hafslund, Bjorg
    EUROPEAN RADIOLOGY, 2020, 30 (08) : 4223 - 4233
  • [26] An evaluation of CAD for mammography in the context of a multi-professional screening service
    Taylor, PM
    Champness, J
    Given-Wilson, RM
    Potts, HWE
    Johnston, K
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 933 - 937
  • [27] LAMIS-DMDB: A new full field digital mammography database for breast cancer AI-CAD researches
    Imane, Otmani
    Mohamed, Amroune
    Lazhar, Rahmani Foued
    Hama, Soltani
    Elhadj, Benkhelifa
    Conci, Aura
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 90
  • [28] Comparative evaluation of digital mammography and film mammography: systematic review and meta-analysis
    Iared, Wagner
    Shigueoka, David Carlos
    Torloni, Maria Regina
    Velloni, Fernanda Garozzo
    Ajzen, Sergio Aron
    Atallah, Alvaro Nagib
    Valente, Orsine
    SAO PAULO MEDICAL JOURNAL, 2011, 129 (04): : 250 - 260
  • [29] Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications
    Clauser, Paola
    Nagl, Georg
    Helbich, Thomas H.
    Pinker-Domenig, Katja
    Weber, Michael
    Kapetas, Panagiotis
    Bernathova, Maria
    Baltzer, Pascal A. T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (12) : 2161 - 2168
  • [30] Performance evaluation of a retrofit digital detector-based mammography system
    Marshall, Nicholas W.
    van Ongeval, Chantal
    Bosmans, Hilde
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 312 - 322