Validation of intratracheal instillation as an alternative for aerosol inhalation toxicity testing

被引:2
|
作者
Sabaitis, CP [1 ]
Leong, BKJ [1 ]
Rop, DA [1 ]
Aaron, CS [1 ]
机构
[1] Pharmacia & Upjohn Inc, Invest Toxicol Worldwide Toxicol, Kalamazoo, MI 49001 USA
关键词
intratracheal; nebulization; instillation; inhalation; intravenous injection; ingestion; rats;
D O I
10.1002/(SICI)1099-1263(199903/04)19:2<133::AID-JAT549>3.0.CO;2-9
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
In collecting inhalation toxicity data for the evaluation of the health hazard from occupational exposure to the aerosols of a drug or a chemical, the determination of the inhaled dose in relation to the animal response is most desirable. Intratracheal administration is most likely to deliver an exact dose of a compound to the lungs of an experimental animal. In a series of tests, microliter (mu l) quantities of a solution or a suspension of a test material were nebulized into the trachea of an anesthetized rat using an intratracheal fast instillation (ITFI) method. The dose-response in terms of the minimal effective dose (MED) and the median lethal dose (LD50) were determined. The ITFI dose-response for four drugs, five chemicals or chemical intermediates and four pesticides were compared with those obtained via inhalation (IH) and ingestion (p.o.), In addition, the dose-responses of the four pesticides were compared with two additional parameters, intranasal instillation (IN) and intravenous injection (i.v.), The MED end-points for studies via the respiratory administration route were no pharmacotoxic signs other than transient respiratory rales and/or dyspnea and no gross lesions, whereas those for the intranasal, oral and the intravenous administration routes were transient and slight body weight loss and no pharmacotoxic signs and/or gross lesions. The MED ratios between ITFI, In and p.o. were 1 : 9.3 +/- 6.5 : 201.4 +/- 133.3, respectively, for the drugs, chemicals and chemical intermediates. The MED ratios for ITFI, IH, IN, i.v. and p.o. for the four pesticides were 1 : 2.2 +/- 1.4 : 2.1 +/- 1.3 : 1.1 +/- 0.7 : 1.4 +/- 0.9. The MED ratios for the two categories of test materials were fairly consistent between different routes of administration. Thus, the ITFI dose can be used for extrapolating the IH dose. The simplicity of the ITFI procedure and its requirement of only microliters of a compound to generate a meaningful and reliable dose-response suggests that ITFI may be an alternative method for acute inhalation toxicity evaluation of materials that may present inhalation hazards from liquid or solid aerosols, Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 50 条
  • [31] Assessment of the toxicity and carcinogenicity of double-walled carbon nanotubes in the rat lung after intratracheal instillation: a two-year study
    Saleh, Dina Mourad
    Luo, Shengyong
    Ahmed, Omnia Hosny Mohamed
    Alexander, David B.
    Alexander, William T.
    Gunasekaran, Sivagami
    El-Gazzar, Ahmed M.
    Abdelgied, Mohamed
    Numano, Takamasa
    Takase, Hiroshi
    Ohnishi, Makoto
    Tomono, Susumu
    Hady, Randa Hussein Abd El
    Fukamachi, Katsumi
    Kanno, Jun
    Hirose, Akihiko
    Xu, Jiegou
    Suzuki, Shugo
    Naiki-Ito, Aya
    Takahashi, Satoru
    Tsuda, Hiroyuki
    PARTICLE AND FIBRE TOXICOLOGY, 2022, 19 (01)
  • [32] Comparison of the Pulmonary Oxidative Stress Caused by Intratracheal Instillation and Inhalation of NiO Nanoparticles when Equivalent Amounts of NiO Are Retained in the Lung
    Horie, Masanori
    Yoshiura, Yukiko
    Izumi, Hiroto
    Oyabu, Takako
    Tomonaga, Taisuke
    Okada, Takami
    Lee, Byeong-Woo
    Myojo, Toshihiko
    Kubo, Masaru
    Shimada, Manabu
    Morimoto, Yasuo
    ANTIOXIDANTS, 2016, 5 (01)
  • [33] A combined dynamic inhalation device designed for moxa-smoking toxicity testing
    Lan Lei
    Chang Xiaorong
    Zhang Guoshan
    Shi Jia
    JOURNAL OF TRADITIONAL CHINESE MEDICINE, 2015, 35 (01) : 90 - 98
  • [34] Subchronic Toxicity and Cardiovascular Responses in Spontaneously Hypertensive Rats after Exposure to Multiwalled Carbon Nanotubes by Intratracheal Instillation
    Chen, Rui
    Zhang, Lili
    Ge, Cuicui
    Tseng, Michael T.
    Bai, Ru
    Qu, Ying
    Beer, Christiane
    Autrup, Herman
    Chen, Chunying
    CHEMICAL RESEARCH IN TOXICOLOGY, 2015, 28 (03) : 440 - 450
  • [35] Evaluation of toxicity to triclosan in rats following 28 days of exposure to aerosol inhalation
    Yang, Young-Su
    Kwon, Jung-Taek
    Shim, Ilseob
    Kim, Hyun-Mi
    Kim, Pilje
    Kim, Jong-Choon
    Lee, Kyuhong
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2015, 71 (02) : 259 - 268
  • [36] Comparison of dose-response relations between 4-week inhalation and intratracheal instillation of NiO nanoparticles using polimorphonuclear neutrophils in bronchoalveolar lavage fluid as a biomarker of pulmonary inflammation
    Mizuguchi, Yohei
    Myojo, Toshihiko
    Oyabu, Takako
    Hashiba, Masayoshi
    Lee, Byeong Woo
    Yamamoto, Makoto
    Todoroki, Motoi
    Nishi, Kenichiro
    Kadoya, Chikara
    Ogami, Akira
    Morimoto, Yasuo
    Tanaka, Isamu
    Shimada, Manabu
    Uchida, Kunio
    Endoh, Shigehisa
    Nakanishi, Junko
    INHALATION TOXICOLOGY, 2013, 25 (01) : 29 - 36
  • [37] Inhalation method for delivery of nanoparticles to the Drosophila respiratory system for toxicity testing
    Posgai, Ryan
    Ahamed, Maqusood
    Hussain, Saber M.
    Rowe, John J.
    Nielsen, Mark G.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2009, 408 (02) : 439 - 443
  • [38] Assessment of the toxicity and carcinogenicity of double-walled carbon nanotubes in the rat lung after intratracheal instillation: a two-year study
    Dina Mourad Saleh
    Shengyong Luo
    Omnia Hosny Mohamed Ahmed
    David B. Alexander
    William T. Alexander
    Sivagami Gunasekaran
    Ahmed M. El-Gazzar
    Mohamed Abdelgied
    Takamasa Numano
    Hiroshi Takase
    Makoto Ohnishi
    Susumu Tomono
    Randa Hussein Abd el Hady
    Katsumi Fukamachi
    Jun Kanno
    Akihiko Hirose
    Jiegou Xu
    Shugo Suzuki
    Aya Naiki-Ito
    Satoru Takahashi
    Hiroyuki Tsuda
    Particle and Fibre Toxicology, 19
  • [39] A combined dynamic inhalation device designed for moxa-smoking toxicity testing
    Lan Lei
    Chang Xiaorong
    Zhang Guoshan
    Shi Jia
    JournalofTraditionalChineseMedicine, 2015, 35 (01) : 90 - 98
  • [40] 1H NMR-based metabolomics study on repeat dose toxicity of fine particulate matter in rats after intratracheal instillation
    Zhang, Yannan
    Hu, Hejing
    Shi, Yanfeng
    Yang, Xiaozhe
    Cao, Lige
    Wu, Jing
    Asweto, Collins Otieno
    Feng, Lin
    Duan, Junchao
    Sun, Zhiwei
    SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 589 : 212 - 221