Immobilization of Glucose Oxidase in GLYMO/MTEOS Sol-Gel Film for Glucose Biosensor Application

被引:0
|
作者
Demirkiran, Nizamettin [1 ]
Ekinci, Ergun [2 ]
机构
[1] Inonu Univ, Fac Engn, Dept Chem Engn, TR-44280 Malatya, Turkey
[2] Inonu Univ, Fac Arts & Sci, Dept Chem, TR-44280 Malatya, Turkey
关键词
Biosensor; Glucose; Glucose oxidase; GLYMO; MTEOS; Sol-gel; ELECTROCHEMICAL BIOSENSORS; COPPER HEXACYANOFERRATE; MODIFIED ELECTRODE; COMPOSITE FILM; SENSOR; SILICA; HYBRID; ENZYME; ENCAPSULATION; TECHNOLOGY;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An electrochemical biosensor was developed by using the sol-gel coating solution. The modified platinum electrode used in the study was constructed by immobilization of glucose oxidase under a layer of sol-gel film. The coating solution was prepared by using GLYMO, and MTEOS. Electrochemical measurements were carried out amperometrically by determining hydrogen peroxide produced by the enzymatic reaction between glucose and glucose oxidase. It was ob served that the amperometric response of the enzyme electrode was linear for gluco se concentrations in the range from 2 to 10 m M. The response time of the biosensor to reach a steady-state cur rent value was approximately 80 s. The glucose selectivity of the biosensor was determined in the presence of some interfering substances, such as lactose, sucrose, urea, uric acid, oxalic acid, and ascorbic acid. It was ob served that the interfering molecules did not cause any observable signal. The stability of the sensor was investigated, and it was found hat the initial sensor response decreased approximately 44% over a period of 30 days of storage in dry state at 4 degrees C.
引用
收藏
页码:302 / 306
页数:5
相关论文
共 50 条
  • [21] Preparation of GOD/Sol-Gel Silica Film on Prussian Blue Modified Electrode for Glucose Biosensor Application
    Liang, Ru-Ping
    Jiang, Jing-Li
    Qiu, Jian -Ding
    ELECTROANALYSIS, 2008, 20 (24) : 2642 - 2648
  • [22] ENTRAPMENT OF GLUCOSE-OXIDASE IN SILICA-GEL BY THE SOL-GEL METHOD AND ITS APPLICATION TO GLUCOSE SENSOR
    TATSU, Y
    YAMASHITA, K
    YAMAGUCHI, M
    YAMAMURA, S
    YAMAMOTO, H
    YOSHIKAWA, S
    CHEMISTRY LETTERS, 1992, (08) : 1615 - 1618
  • [23] Synthesis of ZnO nanobundles via Sol-Gel route and application to glucose biosensor
    Yang Z.
    Ye Z.
    Zhao B.
    Zong X.
    Wang P.
    Journal of Sol-Gel Science and Technology, 2010, 54 (03) : 282 - 285
  • [24] Immobilization of cholesterol esterase and cholesterol oxidase onto sol-gel films for application to cholesterol biosensor
    Singh, Suman
    Singhal, Rahul
    Malhotra, B. D.
    ANALYTICA CHIMICA ACTA, 2007, 582 (02) : 335 - 343
  • [25] An Amperometric Glucose Biosensor Based on Titania Sol-gel/Prussian Blue Composite Film
    Liang, Ruping
    Jiang, Jingli
    Qiu, Jianding
    ANALYTICAL SCIENCES, 2008, 24 (11) : 1425 - 1430
  • [26] An Amperometric Glucose Biosensor Based on Titania Sol-gel/Prussian Blue Composite Film
    Ruping Liang
    Jingli Jiang
    Jianding Qiu
    Analytical Sciences, 2008, 24 : 1425 - 1430
  • [27] Preparation of immobilized glucose oxidase column by sol-gel technique and its application to the chemiluminescent glucose sensor
    Li, QW
    Wang, YM
    Zhang, XR
    Luo, GA
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (11) : 1274 - 1277
  • [28] Determination of Glucose with Biosensor by Immobilization of Glucose Oxidase with Chitosan
    Zhang Yan
    Nan Cai-Feng
    Feng Li
    Zhang Li-Qin
    Dong Chuan
    Shuang Shao-Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (07) : 1049 - 1052
  • [29] Glucose biosensor based on glucose oxidase immobilized in sol-gel chitosan/silica hybrid composite film on Prussian blue modified glass carbon electrode
    Tan, XC
    Tian, YX
    Cai, PX
    Zou, XY
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (02) : 500 - 507
  • [30] AN OPTICAL BIOSENSOR BASED UPON GLUCOSE-OXIDASE IMMOBILIZED IN SOL-GEL SILICATE MATRIX
    SHTELZER, S
    BRAUN, S
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 1994, 19 : 293 - 305