Immobilization of Glucose Oxidase in GLYMO/MTEOS Sol-Gel Film for Glucose Biosensor Application

被引:0
作者
Demirkiran, Nizamettin [1 ]
Ekinci, Ergun [2 ]
机构
[1] Inonu Univ, Fac Engn, Dept Chem Engn, TR-44280 Malatya, Turkey
[2] Inonu Univ, Fac Arts & Sci, Dept Chem, TR-44280 Malatya, Turkey
关键词
Biosensor; Glucose; Glucose oxidase; GLYMO; MTEOS; Sol-gel; ELECTROCHEMICAL BIOSENSORS; COPPER HEXACYANOFERRATE; MODIFIED ELECTRODE; COMPOSITE FILM; SENSOR; SILICA; HYBRID; ENZYME; ENCAPSULATION; TECHNOLOGY;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An electrochemical biosensor was developed by using the sol-gel coating solution. The modified platinum electrode used in the study was constructed by immobilization of glucose oxidase under a layer of sol-gel film. The coating solution was prepared by using GLYMO, and MTEOS. Electrochemical measurements were carried out amperometrically by determining hydrogen peroxide produced by the enzymatic reaction between glucose and glucose oxidase. It was ob served that the amperometric response of the enzyme electrode was linear for gluco se concentrations in the range from 2 to 10 m M. The response time of the biosensor to reach a steady-state cur rent value was approximately 80 s. The glucose selectivity of the biosensor was determined in the presence of some interfering substances, such as lactose, sucrose, urea, uric acid, oxalic acid, and ascorbic acid. It was ob served that the interfering molecules did not cause any observable signal. The stability of the sensor was investigated, and it was found hat the initial sensor response decreased approximately 44% over a period of 30 days of storage in dry state at 4 degrees C.
引用
收藏
页码:302 / 306
页数:5
相关论文
共 40 条
  • [21] Tailoring Sol-Gel-Derived Silica Materials for Optical Biosensing
    Monton, Maria Rowena N.
    Forsberg, Erica M.
    Brennan, John D.
    [J]. CHEMISTRY OF MATERIALS, 2012, 24 (05) : 796 - 811
  • [22] GLUCOSE BIOSENSOR BASED ON A SOL-GEL-DERIVED PLATFORM
    NARANG, U
    PRASAD, PN
    BRIGHT, FV
    RAMANATHAN, K
    KUMAR, ND
    MALHOTRA, BD
    KAMALASANAN, MN
    CHANDRA, S
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (19) : 3139 - 3144
  • [23] Pandey PC, 2001, ELECTROANAL, V13, P820, DOI 10.1002/1521-4109(200106)13:10<820::AID-ELAN820>3.0.CO
  • [24] 2-6
  • [25] Pandey PC, 1999, ELECTROANAL, V11, P59, DOI 10.1002/(SICI)1521-4109(199901)11:1<59::AID-ELAN59>3.3.CO
  • [26] 2-G
  • [27] Characterization of novel glucose oxysilane sol-gel electrochemical biosensors with copper hexacyanoferrate mediator
    Pauliukaite, R
    Brett, CMA
    [J]. ELECTROCHIMICA ACTA, 2005, 50 (25-26) : 4973 - 4980
  • [28] Development of electrochemical biosensors based on sol-gel enzyme encapsulation and protective polymer membranes
    Pauliukaite, Rasa
    Schoenleber, Monika
    Vadgama, Pankaj
    Brett, Christopher M. A.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (04) : 1121 - 1131
  • [29] Effects of titanium content on properties of sol-gel silica-titania films via organically modified silane precursors
    Que, WX
    Sun, Z
    Lam, YL
    Chan, YC
    Kam, CH
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2001, 34 (04) : 471 - 476
  • [30] Electrocatalytic oxidation of dopamine at sol-gel carbon composite electrode chemically modified with copper hexacyanoferrate
    Sabzi, RE
    Zare, S
    Farhadi, K
    Tabrizivand, G