Perfusion imaging of cerebral arteriovenous malformations: a study comparing quantitative continuous arterial spin labeling and dynamic contrast-enhanced magnetic resonance imaging at 3 T

被引:19
作者
Luedemann, Lutz [1 ]
Jedrzejewski, Grzegorz [2 ]
Heidenreich, Jens [2 ]
Han, Eric T. [3 ]
Bruhn, Harald [2 ]
机构
[1] Charite, Klin Strahlentherapie, Campus Virchow Klinikum, Dept Radiotherapy & Radiooncol, D-13353 Berlin, Germany
[2] Charite, Dept Radiol, D-13353 Berlin, Germany
[3] GE Healthcare, Appl Sci Lab W, Menlo Pk, CA USA
关键词
Arteriovenous malformations; AVM; ASL; CASL; Continuous arterial spin labeling; DCE-MRI; Dynamic contrast-enhanced MRI; ROUTINE CLINICAL-PRACTICE; BLOOD-FLOW; SUSCEPTIBILITY CONTRAST; ABSOLUTE QUANTIFICATION; HEMODYNAMIC-CHANGES; MRI; SENSITIVITY;
D O I
10.1016/j.mri.2011.07.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Assessment of hemodynamics in arteriovenous malformations (AVMs) is important for estimating the risk of bleeding as well as planning and monitoring therapy. In tissues with perfusion values significantly higher than cerebral cortex, continuous arterial spin labeling (CASL) permits both adequate representation and quantification of perfusion. Thirteen patients who had cerebral AVMs were examined with two magnetic resonance imaging (MRI) techniques: perfusion imaging using a CASL technique with two delay times, 800 and 1200 ms, and T-2-weighted dynamic contrast-enhanced MRI (T-2-DCE-MRI). The signal-to-noise ratio obtained in our study with the CASL technique at 3 T was sufficient to estimate perfusion in gray matter. Both nidal and venous perfusion turned out larger by factors of 1.71 +/- 2.01 and 2.48 +/- 1.51 in comparison to T-2-DCE-MRI when using CASL at delay times of 800 and 1200 ms, respectively. Moreover, the venous and nidal perfusion values of the AVMs measured at T-2-DCE-MRI did not correlate with those observed at CASL. Evaluation of average perfusion values yielded significantly different results when using a shorter versus a longer delay time. Average gray matter perfusion was 15.8% larger when measured at delay times of w=800 ms versus w=1200 ms, while nidal perfusion was 15.7% larger and venous perfusion was 34.6% larger, respectively. In conclusion, the extremely high perfusion within an AVM could be successfully quantified using CASL. A shorter postlabeling delay time of w=800 ms seems to be more appropriate than a longer time of w=1200 ms because of possible inflow of unlabeled spins at the latter. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:1157 / 1164
页数:8
相关论文
共 32 条
  • [1] Multisection cerebral blood flow MR imaging with continuous arterial spin labeling
    Alsop, DC
    Detre, JA
    [J]. RADIOLOGY, 1998, 208 (02) : 410 - 416
  • [2] Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    Alsop, DC
    Detre, JA
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) : 1236 - 1249
  • [3] Methodology of brain perfusion imaging
    Barbier, EL
    Lamalle, L
    Décorps, M
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) : 496 - 520
  • [4] Measuring cerebral blood flow using magnetic resonance imaging techniques
    Calamante, F
    Thomas, DL
    Pell, GS
    Wiersma, J
    Turner, R
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1999, 19 (07) : 701 - 735
  • [5] Arterial spin-labeling in routine clinical practice, Part 3: Hyperperfusion patterns
    Deibler, A. R.
    Pollock, J. M.
    Kraft, R. A.
    Tan, H.
    Burdette, J. H.
    Maldjian, J. A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (08) : 1428 - 1435
  • [6] Arterial spin-labeling in routine clinical practice, part 1: Technique and artifacts
    Deibler, A. R.
    Pollock, J. M.
    Kraft, R. A.
    Tan, H.
    Burdette, J. H.
    Maldjian, J. A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (07) : 1228 - 1234
  • [7] Arterial spin-labeling in routine clinical practice, part 2: Hypoperfusion patterns
    Deibler, A. R.
    Pollock, J. M.
    Kraft, R. A.
    Tan, H.
    Burdette, J. H.
    Maldjian, J. A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (07) : 1235 - 1241
  • [8] MR perfusion imaging in proliferative angiopathy
    Ducreux, D
    Meder, JF
    Fredy, D
    Bittoun, J
    Lasjaunias, P
    [J]. NEURORADIOLOGY, 2004, 46 (02) : 105 - 112
  • [9] Golay Xavier, 2004, Top Magn Reson Imaging, V15, P10, DOI 10.1097/00002142-200402000-00003
  • [10] Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements
    Günther, M
    Oshio, K
    Feinberg, DA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 491 - 498