Perfusion imaging of cerebral arteriovenous malformations: a study comparing quantitative continuous arterial spin labeling and dynamic contrast-enhanced magnetic resonance imaging at 3 T

被引:19
|
作者
Luedemann, Lutz [1 ]
Jedrzejewski, Grzegorz [2 ]
Heidenreich, Jens [2 ]
Han, Eric T. [3 ]
Bruhn, Harald [2 ]
机构
[1] Charite, Klin Strahlentherapie, Campus Virchow Klinikum, Dept Radiotherapy & Radiooncol, D-13353 Berlin, Germany
[2] Charite, Dept Radiol, D-13353 Berlin, Germany
[3] GE Healthcare, Appl Sci Lab W, Menlo Pk, CA USA
关键词
Arteriovenous malformations; AVM; ASL; CASL; Continuous arterial spin labeling; DCE-MRI; Dynamic contrast-enhanced MRI; ROUTINE CLINICAL-PRACTICE; BLOOD-FLOW; SUSCEPTIBILITY CONTRAST; ABSOLUTE QUANTIFICATION; HEMODYNAMIC-CHANGES; MRI; SENSITIVITY;
D O I
10.1016/j.mri.2011.07.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Assessment of hemodynamics in arteriovenous malformations (AVMs) is important for estimating the risk of bleeding as well as planning and monitoring therapy. In tissues with perfusion values significantly higher than cerebral cortex, continuous arterial spin labeling (CASL) permits both adequate representation and quantification of perfusion. Thirteen patients who had cerebral AVMs were examined with two magnetic resonance imaging (MRI) techniques: perfusion imaging using a CASL technique with two delay times, 800 and 1200 ms, and T-2-weighted dynamic contrast-enhanced MRI (T-2-DCE-MRI). The signal-to-noise ratio obtained in our study with the CASL technique at 3 T was sufficient to estimate perfusion in gray matter. Both nidal and venous perfusion turned out larger by factors of 1.71 +/- 2.01 and 2.48 +/- 1.51 in comparison to T-2-DCE-MRI when using CASL at delay times of 800 and 1200 ms, respectively. Moreover, the venous and nidal perfusion values of the AVMs measured at T-2-DCE-MRI did not correlate with those observed at CASL. Evaluation of average perfusion values yielded significantly different results when using a shorter versus a longer delay time. Average gray matter perfusion was 15.8% larger when measured at delay times of w=800 ms versus w=1200 ms, while nidal perfusion was 15.7% larger and venous perfusion was 34.6% larger, respectively. In conclusion, the extremely high perfusion within an AVM could be successfully quantified using CASL. A shorter postlabeling delay time of w=800 ms seems to be more appropriate than a longer time of w=1200 ms because of possible inflow of unlabeled spins at the latter. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:1157 / 1164
页数:8
相关论文
共 50 条
  • [1] Role of Magnetic Resonance Perfusion Imaging in Acute Stroke: Arterial Spin Labeling Versus Dynamic Susceptibility Contrast-Enhanced Perfusion
    Gopinath, Ganesan
    Aslam, Malik
    Anusha, Palaniswamy
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [2] Renal Perfusion 3-T MR Imaging: A Comparative Study of Arterial Spin Labeling and Dynamic Contrast-enhanced Techniques
    Wu, Wen-Chau
    Su, Mao-Yuan
    Chang, Chin-Cheng
    Tseng, Wen-Yih Isaac
    Liu, Kao-Lang
    RADIOLOGY, 2011, 261 (03) : 845 - 853
  • [3] Arterial spin labeling magnetic resonance perfusion imaging in cerebral ischemia
    Hartkamp, Nolan S.
    van Osch, Matthias J. P.
    Kappelle, Jaap
    Bokkers, Reinoud P. H.
    CURRENT OPINION IN NEUROLOGY, 2014, 27 (01) : 42 - 53
  • [4] Comparative Evaluation of 3-Dimensional Pseudocontinuous Arterial Spin Labeling With Dynamic Contrast-Enhanced Perfusion Magnetic Resonance Imaging in Grading of Human Glioma
    Roy, Bhaswati
    Awasthi, Rishi
    Bindal, Amit
    Sahoo, Prativa
    Kumar, Rajan
    Behari, Sanjay
    Ojha, Bal K.
    Husain, Nuzhat
    Pandey, Chandra M.
    Rathore, Ram K. S.
    Gupta, Rakesh Kumar
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (03) : 321 - 326
  • [5] Hypertension and Cerebral Vasoreactivity A Continuous Arterial Spin Labeling Magnetic Resonance Imaging Study
    Hajjar, Ihab
    Zhao, Peng
    Alsop, David
    Novak, Vera
    HYPERTENSION, 2010, 56 (05) : 859 - U268
  • [6] The therapeutic utility of combining dynamic contrast-enhanced magnetic resonance imaging with arterial spin labeling in the staging of nasopharyngeal carcinoma
    Haodong Li
    Guanzhong Gong
    Lizhen Wang
    Ya Su
    Jie Lu
    Yong Yin
    BMC Medical Imaging, 23
  • [7] The therapeutic utility of combining dynamic contrast-enhanced magnetic resonance imaging with arterial spin labeling in the staging of nasopharyngeal carcinoma
    Li, Haodong
    Gong, Guanzhong
    Wang, Lizhen
    Su, Ya
    Lu, Jie
    Yin, Yong
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [8] Quantitative perfusion imaging in carotid artery stenosis using dynamic susceptibility contrast-enhanced magnetic resonance imaging
    Lythgoe, DJ
    Ostergaard, L
    Williams, SCR
    Cluckie, A
    Buxton-Thomas, M
    Simmons, A
    Markus, HS
    MAGNETIC RESONANCE IMAGING, 2000, 18 (01) : 1 - 11
  • [9] Arterial Spin Labeling Cerebral Perfusion Magnetic Resonance Imaging in Migraine Aura: An Observational Study
    Wolf, Marc E.
    Okazaki, Shuhei
    Eisele, Philipp
    Rossmanith, Christina
    Gregori, Johannes
    Griebe, Martin
    Guenther, Matthias
    Gass, Achim
    Hennerici, Michael G.
    Szabo, Kristina
    Kern, Rolf
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2018, 27 (05): : 1262 - 1266
  • [10] Perfusion of the placenta assessed using arterial spin labeling and ferumoxytol dynamic contrast enhanced magnetic resonance imaging in the rhesus macaque
    Ludwig, Kai D.
    Fain, Sean B.
    Nguyen, Sydney M.
    Golos, Thaddeus G.
    Reeder, Scott B.
    Bird, Ian M.
    Shah, Dinesh M.
    Wieben, Oliver E.
    Johnson, Kevin M.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 1964 - 1978