Effect of Renal Function on Gadolinium-Related Signal Increases on Unenhanced T1-Weighted Brain Magnetic Resonance Imaging

被引:35
|
作者
Cao, Yan [1 ]
Zhang, Yang [1 ,2 ]
Shih, George [1 ]
Zhang, Yan [1 ]
Bohmart, Andrew [3 ]
Hecht, Elizabeth M. [4 ]
Prince, Martin R. [1 ,4 ]
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, 416 E,55th St, New York, NY 10022 USA
[2] Shandong Univ, Qilu Hosp, Dept Radiol, Jinan, Peoples R China
[3] Cornell Univ, Weill Med Coll, Dept Nephrol, New York, NY 10021 USA
[4] Columbia Coll Phys & Surg, Dept Radiol, New York, NY USA
关键词
dentate nucleus; globus pallidus; gadolinium; MRI; choroid plexus; hemodialysis; NEPHROGENIC SYSTEMIC FIBROSIS; HYPERINTENSE BASAL GANGLIA; HEALTHY RATS DIFFERENCE; DEEP CEREBELLAR NUCLEI; DENTATE NUCLEUS; CONTRAST AGENTS; MR-IMAGES; GLOBUS-PALLIDUS; GADOPENTETATE DIMEGLUMINE; MACROCYCLIC-AGENTS;
D O I
10.1097/RLI.0000000000000294
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The purpose of this study was to determine if renal function affects signal changes in the deep brain nuclei on unenhanced T1-weighted images after administration of linear gadolinium-based contrast agents (GBCAs). Methods An electronic medical records search of 2 large medical centers identified 25 patients who received linear GBCA while on hemodialysis and had unenhanced T1-weighted images of the brain before and after. The dentate-to-cerebellar peduncle (DCP) ratio, globus pallidus-to-mid thalamus (GPT) ratio, and choroid plexus-to-nearby white matter ratio were measured and compared with 25 age/sex/GBCA exposure-matched control patients with normal or near-normal renal function (estimated glomerular filtration rate >60 mL/min per 1.73 m(2)). Two additional control groups included 13 patients on hemodialysis without GBCA exposure and 13 age/sex-matched patients with estimated glomerular filtration rate greater than 60 mL/min per 1.73 m(2). Results Hemodialysis patients (n = 25) with an average of 1.8 linear GBCA administrations had a 4.9% mean increase (1.00 0.04 vs 1.05 +/- 0.05; P < 0.001) in DCP, which was greater than the 1.6% change (0.99 +/- 0.04 vs 1.00 +/- 0.05; P = 0.08) observed in matched controls (P = 0.01). There was no significant signal change in the DCP ratio in the 13 hemodialysis patients (0.99 +/- 0.04 vs 0.99 +/- 0.04; P = 0.78) and 13 age/sex-matched patients (0.99 +/- 0.02 vs 0.99 +/- 0.03; P = 0.78) who did not receive GBCA. The hemodialysis patients had a baseline GPT that was higher than nondialysis patients (P < 0.001). However, the GPT change after GBCA administration was not significantly different from controls. Increased signal in the choroid plexus on unenhanced T1-weighted images after GBCA administration was noted in hemodialysis patients (0.72 +/- 0.20 vs 0.86 +/- 0.23; P = 0.006); however, a multivariate analysis showed this to be primarily related to hemodialysis (P = 0.003) with only a trend toward relating to GBCA exposure (P = 0.07). Conclusions Hemodialysis patients receiving linear GBCA have greater dentate nucleus signal increases on unenhanced T1-weighted images, suggesting that renal function may affect the rate of gadolinium accumulation in the brain after linear GBCA-enhanced magnetic resonance imaging.
引用
收藏
页码:677 / 682
页数:6
相关论文
共 50 条
  • [1] Signal Changes in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Magnetic Resonance Images After Intrathecal Administration of Macrocyclic Gadolinium Contrast Agent
    Ozturk, Kerem
    Nas, Omer Fatih
    Soylu, Esra
    Hakyemez, Bahattin
    INVESTIGATIVE RADIOLOGY, 2018, 53 (09) : 535 - 540
  • [2] Effects of serial macrocyclic-based contrast materials gadoterate meglumine and gadobutrol administrations on gadolinium-related dentate nuclei signal increases in unenhanced T1-weighted brain: a retrospective study in 158 multiple sclerosis (MS) patients
    Splendiani, Alessandra
    Perri, Marco
    Marsecano, Claudia
    Vellucci, Valentina
    Michelini, Giulia
    Barile, Antonio
    Di Cesare, Ernesto
    RADIOLOGIA MEDICA, 2018, 123 (02): : 125 - 134
  • [3] Changes in signal intensity in the dentate nucleus at unenhanced T1-weighted magnetic resonance imaging depending on class of previously used gadolinium-based contrast agent
    Kasper, Eileen
    Schemuth, Haemi Phaedra
    Horry, Samantha
    Kinner, Sonja
    PEDIATRIC RADIOLOGY, 2018, 48 (05) : 686 - 693
  • [4] A retrospective cohort evaluation of the effect of multiple administrations of gadopentetate dimeglumine on brain magnetic resonance imaging T1-weighted signal
    Towbin, Alexander J.
    Zhang, Bin
    Dillman, Jonathan R.
    PEDIATRIC RADIOLOGY, 2021, 51 (03) : 457 - 470
  • [5] Increased Signal Intensity in the Dentate Nucleus on Unenhanced T1-Weighted Images After Gadobenate Dimeglumine Administration
    Weberling, Lukas D.
    Kieslich, Pascal J.
    Kickingereder, Philipp
    Wick, Wolfgang
    Bendszus, Martin
    Schlemmer, Heinz-Peter
    Radbruch, Alexander
    INVESTIGATIVE RADIOLOGY, 2015, 50 (11) : 743 - 748
  • [6] Standardized assessment of the signal intensity increase on unenhanced T1-weighted images in the brain: the European Gadolinium Retention Evaluation Consortium (GREC) Task Force position statement
    Quattrocchi, Carlo C.
    Ramalho, Joana
    van der Molen, Aart J.
    Rovira, Alex
    Radbruch, Alexander
    EUROPEAN RADIOLOGY, 2019, 29 (08) : 3959 - 3967
  • [7] Intrathecal Contrast-Enhanced Magnetic Resonance Imaging-Related Brain Signal Changes Residual Gadolinium Deposition?
    Oner, Ali Yusuf
    Barutcu, Berrak
    Aykol, Sukru
    Tali, Emin Turgut
    INVESTIGATIVE RADIOLOGY, 2017, 52 (04) : 195 - 197
  • [8] Pediatric Brain Gadolinium Deposition in Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images Is Dependent on the Type of Contrast Agent
    Ryu, Young Jin
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, Woo-Jin
    Park, Subin
    Park, Ji Eun
    Kim, Woo Sun
    Kim, In-One
    INVESTIGATIVE RADIOLOGY, 2018, 53 (04) : 246 - 255
  • [9] Repeated intravenous administration of gadobutrol does not lead to increased signal intensity on unenhanced T1-weighted images-a voxel-based whole brain analysis
    Langner, Soenke
    Kromrey, Marie-Luise
    Kuehn, Jens-Peter
    Grothe, Matthias
    Domin, Martin
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3687 - 3693
  • [10] Pediatric Brain: Repeated Exposure to Linear Gadolinium-based Contrast Material Is Associated with Increased Signal Intensity at Unenhanced T1-weighted MR Imaging
    Flood, Thomas F.
    Stence, Nicholas V.
    Maloney, John A.
    Mirsky, David M.
    RADIOLOGY, 2017, 282 (01) : 222 - 228