Absolute Change in High-Sensitivity Cardiac Troponin I at Three Hours After Presentation is Useful for Diagnosing Acute Myocardial Infarction in the Emergency Department

被引:11
|
作者
Kim, Jong Won [1 ]
Kim, Hanah [2 ]
Yun, Yeo-Min [2 ]
Lee, Kyeong Ryong [1 ]
Kim, Hyun Joong [3 ]
机构
[1] Konkuk Univ, Med Ctr, Sch Med, Dept Emergency Med, Seoul, South Korea
[2] Konkuk Univ, Med Ctr, Sch Med, Dept Lab Med, Seoul, South Korea
[3] Konkuk Univ, Med Ctr, Sch Med, Div Cardiol,Dept Internal Med, Seoul, South Korea
关键词
Acute myocardial infarction; Chest pain; High-sensitivity cardiac troponin I; Emergency department; Absolute change; ACUTE CORONARY SYNDROME; RELATIVE CHANGES; RULE-OUT; ASSAY; BIOMARKERS;
D O I
10.3343/alm.2020.40.6.474
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: A rise and/or fall in cardiac troponin value with at least one value above the 99th percentile upper reference limit is essential for acute myocardial infarction (AMI) diagnosis. We evaluated the clinical usefulness of serial high-sensitivity cardiac troponin I (hs-cTnI) measurements in AMI diagnosis, in terms of the predictability of absolute and relative changes. Methods: For this retrospective, forward observational study, we enrolled 281 patients older than 18 years who presented with chest pain at the emergency department (ED) between August 2015 and December 2016. The patients were grouped as AMI and non-AMI, and 73 (26%) were diagnosed as having AMI. Hs-cTnI (Abbott Diagnostics, Abbott Park, IL, USA) was measured at presentation and 3 hours later. We assessed the diagnostic performance of the absolute and relative changes in hs-cTnI. Results: The cut-off values to predict AMI were 16.2 ng/L and 42.1% for the absolute and relative hs-cTnI changes, respectively. The area under the curve of hs-cTnI for AMI diagnosis was larger for absolute changes than for relative changes [0.96 (95% confidence interval [CI], 0.92-0.98) vs 0.89 (95% CI, 0.85-0.93)] (P=0.014). Conclusions: The absolute hs-cTnI change at 3 hours after presentation was superior to the relative change, and a rise and/or fall in hs-cTnI of >16.2 ng/L at 3 hours after presentation was useful to identify AMI in patients presenting at the ED.
引用
收藏
页码:474 / 480
页数:7
相关论文
共 50 条
  • [1] Myocardial Infarction Can Be Safely Excluded by High-sensitivity Troponin I Testing 3 Hours After Emergency Department Presentation
    Peacock, W. Frank
    Christenson, Robert
    Diercks, Deborah B.
    Fromm, Christian
    Headden, Gary F.
    Hogan, Christopher J.
    Kulstad, Erik B.
    LoVecchio, Frank
    Nowak, Richard M.
    Schrock, Jon W.
    Singer, Adam J.
    Storrow, Alan B.
    Straseski, Joely
    Wu, Alan H. B.
    Zelinski, Daniel P.
    ACADEMIC EMERGENCY MEDICINE, 2020, 27 (08) : 671 - 680
  • [2] Absolute Change in High Sensitivity Cardiac Troponin I for Three Hours is Useful for Diagnosing Acute Myocardial Infarction in the Emergency Department: How to Get to Best Benefit From HS-Troponins in Clinical Practice?
    Huet, Fabien
    Dupuy, Anne Marie
    Cristol, Jean Paul
    Roubille, Francois
    ANNALS OF LABORATORY MEDICINE, 2020, 40 (06) : 488 - 489
  • [3] High-Sensitivity Cardiac Troponin Risk Cutoffs for Acute Cardiac Outcomes at Emergency Department Presentation
    Kavsak, Peter A.
    Worster, Andrew
    Ma, Jinhui
    Shortt, Colleen
    Clayton, Natasha
    Sherbino, Jonathan
    Hill, Stephen A.
    McQueen, Matthew
    Mehta, Shamir R.
    Devereaux, Philip J.
    CANADIAN JOURNAL OF CARDIOLOGY, 2017, 33 (07) : 898 - 903
  • [4] Single High-Sensitivity Cardiac Troponin I to Rule Out Acute Myocardial Infarction
    Sandoval, Yader
    Smith, Stephen W.
    Love, Sara A.
    Sexter, Anne
    Schulz, Karen
    Apple, Fred S.
    AMERICAN JOURNAL OF MEDICINE, 2017, 130 (09) : 1076 - +
  • [5] Profile of Roche's Elecsys Troponin T Gen 5 STAT blood test (a high-sensitivity cardiac troponin assay) for diagnosing myocardial infarction in the emergency department
    Kavsak, Peter A.
    Andruchow, James E.
    McRae, Andrew D.
    Worster, Andrew
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2018, 18 (06) : 481 - 489
  • [6] Undetectable High-Sensitivity Cardiac Troponin T Level in the Emergency Department and Risk of Myocardial Infarction
    Bandstein, Nadia
    Ljung, Rickard
    Johansson, Magnus
    Holzmann, Martin J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (23) : 2569 - 2577
  • [7] High-sensitivity cardiac troponin concentrations at emergency department presentation in females and males with an acute cardiac outcome
    Kavsak, Peter A.
    Worster, Andrew
    Shortt, Colleen
    Ma, Jinhui
    Clayton, Natasha
    Sherbino, Jonathan
    Hill, Stephen A.
    McQueen, Matthew
    Griffith, Lauren
    Mehta, Shamir R.
    Devereaux, P. J.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2018, 55 (05) : 604 - 607
  • [8] Combining High-Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction
    van der Linden, Noreen
    Wildi, Karin
    Twerenbold, Raphael
    Pickering, John W.
    Than, Martin
    Cullen, Louise
    Greenslade, Jaimi
    Parsonage, William
    Nestelberger, Thomas
    Boeddinghaus, Jasper
    Badertscher, Patrick
    Rubini Gimenez, Maria
    Klinkenberg, Lieke J. J.
    Bekers, Otto
    Schoni, Aline
    Keller, Dagmar I.
    Sabti, Zaid
    Puelacher, Christian
    Cupa, Janosch
    Schumacher, Lukas
    Kozhuharov, Nikola
    Grimm, Karin
    Shrestha, Samyut
    Flores, Dayana
    Freese, Michael
    Stelzig, Claudia
    Strebel, Ivo
    Miro, Oscar
    Rentsch, Katharina
    Morawiec, Beata
    Kawecki, Damian
    Kloos, Wanda
    Lohrmann, Jens
    Richards, A. Mark
    Troughton, Richard
    Pemberton, Christopher
    Osswald, Stefan
    van Dieijen-Visser, Marja P.
    Mingels, Alma M.
    Reichlin, Tobias
    Meex, Steven J. R.
    Mueller, Christian
    CIRCULATION, 2018, 138 (10) : 989 - 999
  • [9] High-sensitivity versus conventional troponin in the emergency department for the diagnosis of acute myocardial infarction
    Yonathan Freund
    Camille Chenevier-Gobeaux
    Pascale Bonnet
    Yann-Erick Claessens
    Jean-Christophe Allo
    Benoit Doumenc
    François Leumani
    Claudine Cosson
    Bruno Riou
    Patrick Ray
    Critical Care, 15
  • [10] Combining presentation high-sensitivity cardiac troponin I and glucose measurements to rule-out an acute myocardial infarction in patients presenting to emergency department with chest pain
    Greenslade, J. H.
    Kavsak, P.
    Parsonage, W.
    Shortt, C.
    Than, M.
    Pickering, J. W.
    Aldous, S.
    Cullen, L.
    CLINICAL BIOCHEMISTRY, 2015, 48 (4-5) : 288 - 291