A histological and ultrastructural evaluation of the patellar tendon 10 years after reharvesting its central third

被引:23
|
作者
Liden, Mattias [1 ]
Movin, Tomas [2 ]
Ejerhed, Lars [3 ,4 ]
Papadogiannakis, Nikos [5 ]
Blomen, Eva [5 ]
Hultenby, Kjell [5 ]
Kartus, Jueri [3 ]
机构
[1] Sahlgrens Univ Hosp, Dept Plast Surg, SE-41345 Gothenburg, Sweden
[2] Karolinska Univ Hosp Huddinge, Karolinska Inst, Dept Orthopaed, Stockholm, Sweden
[3] Norra Alvsborg Cty Hosp, Dept Orthopaed, Trollhattan, Sweden
[4] Fyrbodal Res Inst, Uddevalla, Sweden
[5] Karolinska Univ Hosp Huddinge, Karolinska Inst, Dept Lab Med, Stockholm, Sweden
关键词
anterior cruciate ligament (ACL); patellar tendon; surgery; reharvest; ultrastructure; transmission electron microscopy; histology;
D O I
10.1177/0363546507311092
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: This study was undertaken to evaluate the histologic and ultrastructural characteristics of the patellar tendon 10 years after reharvesting its central third. Hypothesis: In the long term, after its central third is reharvested, the patellar tendon does not regain a normal histological and ultrastructural appearance. Study Design: Case-control study; Level of evidence, 3. Methods: Twelve consecutive patients ( 4 women, 8 men) who underwent anterior cruciate ligament revision surgery using reharvested ipsilateral patellar tendon autografts were included in the study. Percutaneous biopsy samples were obtained from the central and lateral parts of the patellar tendon under ultrasonographic guidance at a median of 116 months ( range, 102- 127 months) after the revision procedure. Eleven biopsy specimens from asymptomatic patellar tendons obtained from open anterior cruciate ligament reconstructions served as controls. The histologic characteristics and the presence of glycosaminoglycans were assessed using a light microscope, and the ultrastructure was assessed using a transmission electron microscope. Results: The histological evaluation revealed deterioration in fiber structure, increased cellularity, and increased vascularity in both the central and peripheral parts of the reharvested patellar tendon specimens compared with normal tendon specimens. No difference in the amount of glycosaminoglycans was seen in specimens from either part of the reharvested patellar tendons and the control specimens. The ultrastructural evaluation revealed that all the control specimens had a normal morphologic appearance and a compact extracellular matrix with regularly oriented collagen fibrils. Furthermore, in the control specimens, the fibril diameter was heterogeneous, with all fibril size classes present. Specimens from the central and the lateral part of the reharvested tendon displayed pathological cell appearance and a more heterogeneous extracellular matrix. The lateral specimens from the reharvested tendons also displayed all fibril size classes but with a more homogeneous distribution. In the central specimens, the largest fibril size class was absent. Conclusion: Ten years after its central third was reharvested for anterior cruciate ligament revision surgery, the patellar tendon had not normalized in terms of its histological and ultrastructural appearance.
引用
收藏
页码:781 / 788
页数:8
相关论文
共 50 条
  • [1] Ultrastructural collagen fibril alterations in the patellar tendon 6 years after harvesting its central third
    Svensson, Michael
    Movin, Tomas
    Rostgard-Christensen, Lars
    Blomen, Eva
    Hultenby, Kjell
    Kartus, Jori
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (02) : 301 - 306
  • [2] A long-term serial histological evaluation of the patellar tendon in humans after harvesting its central third
    Svensson, M
    Kartus, J
    Christensen, LR
    Movin, T
    Papadogiannakis, N
    Karlsson, J
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (05) : 398 - 404
  • [3] A long-term serial histological evaluation of the patellar tendon in humans after harvesting its central third
    Michael Svensson
    Jüri Kartus
    Lars Rostgård Christensen
    Tomas Movin
    Nikos Papadogiannakis
    Jon Karlsson
    Knee Surgery, Sports Traumatology, Arthroscopy, 2005, 13 : 398 - 404
  • [4] The course of the patellar tendon after reharvesting its central third for ACL revision surgery: a long-term clinical and radiographic study
    Mattias Lidén
    Lars Ejerhed
    Ninni Sernert
    Åke Bovaller
    Jon Karlsson
    Jüri Kartus
    Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 1130 - 1138
  • [5] The course of the patellar tendon after reharvesting its central third for ACL revision surgery:: a long-term clinical and radiographic study
    Liden, Mattias
    Ejerhed, Lars
    Sernert, Ninni
    Bovaller, Ake
    Karlsson, Jon
    Kartus, Juri
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (11) : 1130 - 1138
  • [6] Patellar tendon healing after removal of its central third - A morphologic evaluation in rabbits
    Milano, G
    Gigante, A
    Panni, AS
    Mulas, PD
    Fabbriciani, C
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2001, 9 (02) : 92 - 101
  • [7] Does the patellar tendon normalize after harvesting its central third? A prospective long-term MRI study
    Svensson, M
    Kartus, J
    Ejerhed, L
    Lindahl, S
    Karlsson, J
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (01) : 34 - 38
  • [8] Serial ultrasonographic imaging evaluation of the patellar tendon after harvesting its central one third for anterior cruciate ligament reconstruction
    Wiley, JP
    Bray, RC
    Wiseman, DA
    Elliott, PD
    Ladly, KO
    Vale, LA
    JOURNAL OF ULTRASOUND IN MEDICINE, 1997, 16 (04) : 251 - 255
  • [9] Patellar tendon rupture 3 years after anterior cruciate ligament reconstruction with a central one third bone-patellar tendon-bone graft
    Mickelsen, PL
    Morgan, SJ
    Johnson, WA
    Ferrari, JD
    ARTHROSCOPY, 2001, 17 (06): : 648 - 652
  • [10] Patella position and biomechanical properties of the patellar tendon 1 year after removal of its central third
    Hanselmann, KF
    Durselen, L
    Augat, P
    Claes, L
    CLINICAL BIOMECHANICS, 1997, 12 (04) : 267 - 271