Analysis of metal elements by solution cathode glow discharge-atomic emission spectrometry with a modified pulsation damper

被引:29
|
作者
Wang, Jinmei [1 ]
Tang, Pengfei [1 ]
Zheng, Peichao [1 ]
Zhai, Xiang [1 ]
机构
[1] Chongqing Univ Posts & Telecommun, Coll Optoelect Engn, Chongqing Municipal Level Key Lab Photoelect Info, Chongqing 400065, Peoples R China
关键词
FLOWING ELECTROLYTE-SOLUTIONS; APGD IONIZATION SOURCE; ATMOSPHERIC-PRESSURE; LIQUID CATHODE; ONLINE SEPARATION; ANALYTICAL PERFORMANCE; MASS-SPECTROMETRY; CONTACT; SAMPLES; PRECONCENTRATION;
D O I
10.1039/c7ja00212b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solution-cathode glow discharge-atomic emission spectrometry (SCGD-AES) with a portable spectrometer was used to detect metal elements in solution. A modified pulsation damper was designed and optimized to improve discharge plasma stability. The effects of pulsation damper parameters as well as the discharge current and solution flow rate were investigated. The plasma stability of Na, K and Li elements under optimized parameters with the modified pulsation damper was discussed and they showed good stability over a long time. The standard deviation (SD) of background intensity was low, and the detection limits for Zn, Mg, Ag, Pb, Sr, Na, Li, K, Rb and Cs were 72, 2.1, 1.2, 35, 86, 0.04, 0.16, 0.14, 0.38 and 1.1 mu g L-1, respectively. Ag, Zn and Pb elements in a certified reference material were quantitatively analyzed, and the measurement results obtained by SCGD-AES agreed well with the reference values. Specifically, the precision (relative standard deviation of 10 measured values) of detection was lower than 1.85%. The results show that the SCGD-AES system with the modified pulsation damper can accurately and stably detect the content of metal elements in water.
引用
收藏
页码:1925 / 1931
页数:7
相关论文
共 50 条
  • [21] Highly sensitive elemental analysis of Cd and Zn by solution anode glow discharge atomic emission spectrometry
    Liu, Xing
    Zhu, Zhenli
    He, Dong
    Zheng, Hongtao
    Gan, Yiqun
    Belshaw, Nicholas Stanley
    Hu, Shenghong
    Wang, Yanxin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (05) : 1089 - 1096
  • [22] Solution Cathode Glow Discharge-Atomic Emission Spectroscopy Coupled With Hydride Generation for Detecting Trace Mercury and Tin in Water
    Zheng Pei-chao
    Liu Ran-ning
    Wang Jin-mei
    Feng Chu-hui
    He Yu-tong
    Wu Mei-ni
    He Yu-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (04) : 1139 - 1143
  • [23] Analysis of Solution Cathode Glow Discharge Atomic Emission Spectroscopy by the Multiple Linear Regression Method
    Zheng Pei-chao
    Zhai Xiang
    Wang Jin-mei
    Yang Rui
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (10) : 3209 - 3213
  • [24] Determination of gallium in water samples by atomic emission spectrometry based on solution cathode glow discharge
    Li, Hongwei
    Zu, Wenchuan
    Liu, Fengkui
    Wang, Yu
    Yang, Yin
    Yang, Xiaotao
    Liu, Cong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 152 : 25 - 29
  • [25] Sensitive Determination of Alkali Metals by Liquid Anode Glow Discharge-Atomic Emission Spectrometry (LAGD-AES)
    Yu, Jie
    Wang, Kai
    Feng, Yan
    Hao, Xiaoxia
    Li, Xuehe
    Lu, Quanfang
    ANALYTICAL LETTERS, 2024,
  • [26] Improved solution cathode glow discharge micro-plasma source with a geometrically optimized stainless steel auxiliary cathode for optical emission spectrometry of metal elements
    Zheng, Peichao
    Luo, Yuanjiang
    Wang, Jinmei
    Yang, Yang
    Hu, Qiang
    Mao, Xuefeng
    Lai, Chunhong
    MICROCHEMICAL JOURNAL, 2022, 172
  • [27] Flow Injection Photochemical Vapor Generation Coupled with Miniaturized Solution-Cathode Glow Discharge Atomic Emission Spectrometry for Determination and Speciation Analysis of Mercury
    Mo, Jiamei
    Li, Qing
    Guo, Xiaohong
    Zhang, Guoxia
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2017, 89 (19) : 10353 - 10360
  • [28] A pulsed electrolyte cathode discharge used for metal element analysis by atomic emission spectrometry
    Yuan, Hao
    Yang, De-Zheng
    Li, Xiao
    Zhang, Li
    Zhou, Xiong-Feng
    Wang, Wen-Chun
    Xu, Yong
    PHYSICS OF PLASMAS, 2019, 26 (05)
  • [29] Highly Sensitive Determination of Cadmium by Atomic Emission Spectrometry with Miniaturized Solution Anode Glow Discharge
    Yu, Jie
    Wang, Xuyi
    Cui, Lijuan
    Hao, Xiaoxia
    Lu, Quanfang
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (09) : 1229 - 1241
  • [30] High Sensitive Determination of Pb and Zn in Refined Copper Ores Samples Using Liquid Cathode Glow Discharge-Atomic Emission Spectrometry
    Yu Jie
    Zhu Shu-wen
    Lu Quan-fang
    Zhang Zhi-chao
    Zhang Xiao-min
    Wang Xing
    Yang Wu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (11) : 3550 - 3557