Analysis of metal elements by solution cathode glow discharge-atomic emission spectrometry with a modified pulsation damper

被引:29
|
作者
Wang, Jinmei [1 ]
Tang, Pengfei [1 ]
Zheng, Peichao [1 ]
Zhai, Xiang [1 ]
机构
[1] Chongqing Univ Posts & Telecommun, Coll Optoelect Engn, Chongqing Municipal Level Key Lab Photoelect Info, Chongqing 400065, Peoples R China
关键词
FLOWING ELECTROLYTE-SOLUTIONS; APGD IONIZATION SOURCE; ATMOSPHERIC-PRESSURE; LIQUID CATHODE; ONLINE SEPARATION; ANALYTICAL PERFORMANCE; MASS-SPECTROMETRY; CONTACT; SAMPLES; PRECONCENTRATION;
D O I
10.1039/c7ja00212b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solution-cathode glow discharge-atomic emission spectrometry (SCGD-AES) with a portable spectrometer was used to detect metal elements in solution. A modified pulsation damper was designed and optimized to improve discharge plasma stability. The effects of pulsation damper parameters as well as the discharge current and solution flow rate were investigated. The plasma stability of Na, K and Li elements under optimized parameters with the modified pulsation damper was discussed and they showed good stability over a long time. The standard deviation (SD) of background intensity was low, and the detection limits for Zn, Mg, Ag, Pb, Sr, Na, Li, K, Rb and Cs were 72, 2.1, 1.2, 35, 86, 0.04, 0.16, 0.14, 0.38 and 1.1 mu g L-1, respectively. Ag, Zn and Pb elements in a certified reference material were quantitatively analyzed, and the measurement results obtained by SCGD-AES agreed well with the reference values. Specifically, the precision (relative standard deviation of 10 measured values) of detection was lower than 1.85%. The results show that the SCGD-AES system with the modified pulsation damper can accurately and stably detect the content of metal elements in water.
引用
收藏
页码:1925 / 1931
页数:7
相关论文
共 50 条
  • [11] A novel solution cathode glow discharge geometry for improved coupling to optical emission spectrometry
    Hazel, Nicholas
    Orejas Ibanez, Jaime
    Ray, Steven
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (06) : 1229 - 1239
  • [12] Determination of calcium and zinc in gluconates oral solution and blood samples by liquid cathode glow discharge-atomic emission spectrometry
    Yu, Jie
    Zhang, Xiaomin
    Lu, Quanfang
    Wang, Xing
    Sun, Duixiong
    Wang, Yongqiang
    Yang, Wu
    TALANTA, 2017, 175 : 150 - 157
  • [13] Elemental Analysis of Environmental Waters by Solution Cathode Glow Discharge-Atomic Emission Spectrometry (SCGD-AES) with a Multifunctional Injection System
    Zheng, Peichao
    Hu, Qiang
    Zhang, Hangxi
    Wang, Jinmei
    Yang, Yang
    He, Yuxin
    Wu, Meini
    Tian, Hongwu
    Dong, Daming
    Mao, Xuefeng
    Lai, Chunhong
    ANALYTICAL LETTERS, 2022, 55 (14) : 2273 - 2285
  • [14] A portable solution cathode glow discharge-atomic emission spectrometer for the rapid determination of thallium in water samples
    Zu, Wenchuan
    Wang, Yu
    Yang, Xiaotao
    Liu, Cong
    TALANTA, 2017, 173 : 88 - 93
  • [15] Ultra-sensitive determination of inorganic arsenic valence by solution cathode glow discharge-atomic emission spectrometry coupled with hydride generation
    Guo, Xiaohong
    Peng, Xiaoxu
    Li, Qing
    Mo, Jiamei
    Du, Yiping
    Wang, Zheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (12) : 2416 - 2422
  • [16] Determination of trace heavy metals in environmental and biological samples by solution cathode glow discharge-atomic emission spectrometry and addition of ionic surfactants for improved sensitivity
    Zhang, Zhen
    Wang, Zheng
    Li, Qing
    Zou, Huijun
    Shi, Ying
    TALANTA, 2014, 119 : 613 - 619
  • [17] On-line separation and preconcentration of hexavalent chromium on a novel mesoporous silica adsorbent with determination by solution-cathode glow discharge-atomic emission spectrometry
    Ma, Jiaxian
    Wang, Zheng
    Li, Qing
    Gai, Rongyin
    Li, Xiaohong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (12) : 2315 - 2322
  • [18] Sensitivity improvement of solution cathode glow discharge-optical emission spectrometry by external magnetic field for optical determination of elements
    Zhou, Yong-Jie
    Ma, Jun
    Li, Fei
    Xian, Tao
    Yuan, Qiang-Hua
    Lu, Quan-Fang
    MICROCHEMICAL JOURNAL, 2020, 158
  • [19] Liquid Cathode Glow Discharge as an Excitation Source for the Analysis of Complex Water Samples with Atomic Emission Spectrometry
    Yu, Jie
    Zhang, Xiaomin
    Lu, Quanfang
    Yin, Ling
    Feng, Feifei
    Luo, Hui
    Kang, Yuejing
    ACS OMEGA, 2020, 5 (31): : 19541 - 19547
  • [20] Rapid determination of indium in water samples using a portable solution cathode glow discharge-atomic emission spectrometer
    Zu, Wenchuan
    Yang, Yin
    Wang, Yu
    Yang, Xiaotao
    Liu, Cong
    Ren, Min
    MICROCHEMICAL JOURNAL, 2018, 137 : 266 - 271