Analysis of metal elements by solution cathode glow discharge-atomic emission spectrometry with a modified pulsation damper

被引:29
|
作者
Wang, Jinmei [1 ]
Tang, Pengfei [1 ]
Zheng, Peichao [1 ]
Zhai, Xiang [1 ]
机构
[1] Chongqing Univ Posts & Telecommun, Coll Optoelect Engn, Chongqing Municipal Level Key Lab Photoelect Info, Chongqing 400065, Peoples R China
关键词
FLOWING ELECTROLYTE-SOLUTIONS; APGD IONIZATION SOURCE; ATMOSPHERIC-PRESSURE; LIQUID CATHODE; ONLINE SEPARATION; ANALYTICAL PERFORMANCE; MASS-SPECTROMETRY; CONTACT; SAMPLES; PRECONCENTRATION;
D O I
10.1039/c7ja00212b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solution-cathode glow discharge-atomic emission spectrometry (SCGD-AES) with a portable spectrometer was used to detect metal elements in solution. A modified pulsation damper was designed and optimized to improve discharge plasma stability. The effects of pulsation damper parameters as well as the discharge current and solution flow rate were investigated. The plasma stability of Na, K and Li elements under optimized parameters with the modified pulsation damper was discussed and they showed good stability over a long time. The standard deviation (SD) of background intensity was low, and the detection limits for Zn, Mg, Ag, Pb, Sr, Na, Li, K, Rb and Cs were 72, 2.1, 1.2, 35, 86, 0.04, 0.16, 0.14, 0.38 and 1.1 mu g L-1, respectively. Ag, Zn and Pb elements in a certified reference material were quantitatively analyzed, and the measurement results obtained by SCGD-AES agreed well with the reference values. Specifically, the precision (relative standard deviation of 10 measured values) of detection was lower than 1.85%. The results show that the SCGD-AES system with the modified pulsation damper can accurately and stably detect the content of metal elements in water.
引用
收藏
页码:1925 / 1931
页数:7
相关论文
共 50 条
  • [1] Direct determination of Cu by liquid cathode glow discharge-atomic emission spectrometry
    Lu, Quanfang
    Yang, Shuxiu
    Sun, Duixiong
    Zheng, Jidong
    Li, Yun
    Yu, Jie
    Su, Maogen
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 125 : 136 - 139
  • [2] Elemental Analysis of Mineral Water by Solution-Cathode Glow Discharge-Atomic Emission Spectrometry
    Zheng, Peichao
    Gong, Yaming
    Wang, Jinmei
    Zeng, Xiaobo
    ANALYTICAL LETTERS, 2017, 50 (09) : 1512 - 1520
  • [3] Analytical Performance of Hollow Anode-Solution Cathode Glow Discharge-Atomic Emission Spectrometry
    Zheng, Peichao
    Li, Weiqi
    Wang, Jinmei
    Wang, Ningshen
    Zhong, Chao
    Luo, Yuanjiang
    Wang, Xiaofa
    Mao, Xuefeng
    Lai, Chunhong
    ANALYTICAL LETTERS, 2020, 53 (05) : 693 - 704
  • [4] Simultaneously determination of multi metal elements in water samples by liquid cathode glow discharge-atomic emission spectrometry
    Yu, Jie
    Yang, Shuxiu
    Sun, Duixiong
    Lu, Quanfang
    Zheng, Jidong
    Zhang, Xiaomei
    Wang, Xing
    MICROCHEMICAL JOURNAL, 2016, 128 : 325 - 330
  • [5] Evaluation of analytical performance for the simultaneous detection of trace Cu, Co and Ni by using liquid cathode glow discharge-atomic emission spectrometry
    Yu, Jie
    Zhang, Xiaomin
    Lu, Quanfang
    Sun, Duixiong
    Wang, Xing
    Zhu, Shuwen
    Zhang, Zhichao
    Yang, Wu
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 145 : 64 - 70
  • [6] Ultratrace Determination of Tin, Germanium, and Selenium by Hydride Generation Coupled with a Novel Solution-Cathode Glow Discharge-Atomic Emission Spectrometry Method
    Huang, Chuchu
    Li, Qing
    Mo, Jiamei
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2016, 88 (23) : 11559 - 11567
  • [7] Evaluation of liquid cathode glow discharge-atomic emission spectrometry for determination of copper and lead in ores samples
    Yu, Jie
    Yang, Shuxiu
    Lu, Quanfang
    Sun, Duixiong
    Zheng, Jidong
    Zhang, Xiaomin
    Wang, Xing
    Yang, Wu
    TALANTA, 2017, 164 : 216 - 221
  • [8] Ultratrace Pb determination in seawater by solution-cathode glow discharge-atomic emission spectrometry coupled with hydride generation
    Cheng, Junqi
    Li, Qing
    Zhao, Mingyue
    Wang, Zheng
    ANALYTICA CHIMICA ACTA, 2019, 1077 : 107 - 115
  • [9] Determination of gallium and indium by solution cathode glow discharge as an excitation source for atomic emission spectrometry
    Yu, Jie
    Kang, Yuejing
    Lu, Quanfang
    Luo, Hui
    Cui, Lijuan
    Lu, Zhuanhong
    Li, Juanlong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 172
  • [10] Evaluation of solution-cathode glow discharge atomic emission spectrometry for the analysis of nanoparticle containing solutions
    Hazel, Nicholas
    Orejas, Jaime
    Ray, Steven J.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 176 (176)