Non-invasive investigation of skin local hypothermia influence upon local oxygenation and hemoglobin concentration

被引:0
|
作者
Yu, DA
Kessler, M
Kakihana, Y
Krug, A
机构
来源
OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE: THEORY, INSTRUMENTATION, MODEL, AND HUMAN STUDIES II, PROCEEDINGS OF | 1997年 / 2979卷
关键词
PDT; optical monitoring; fiber spectrometer; hemoglobin; oxygenation;
D O I
10.1117/12.280267
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Functional evaluation of local hemoglobin concentration and hemoglobin oxygenation based on back scattering spectra from human skin in vivo have been obtained in visible range (502-628 nm) by a rapid micro-lightguide spectrometer (EMPHO II) with step 250 mu m. Analysis of received results has shown that during local cooling there is two nearly simultaneous reactions: reduction of hemoglobin concentration and increase of hemoglobin oxygenation level. In a case when one has used previous heating of planning place for cooling, reduction of hemoglobin concentration is expressed higher by 22-33 %.
引用
收藏
页码:375 / 377
页数:3
相关论文
共 7 条
  • [1] Influence of hemoglobin on non-invasive optical bilirubin sensing
    Jiang, Jingying
    Gong, Qiliang
    Zou, Da
    Xu, Kexin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IX, 2012, 8222
  • [2] Non-invasive Measurement of Hemoglobin Concentration Using Magnetic Plethysmo Gram
    Bai, Rezuana J.
    Mohanasankar, S.
    Kumar, Jagadeesh, V
    2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2016, : 435 - 440
  • [3] Non-invasive skin oxygenation imaging using a multi-spectral imaging system, Effectiveness of different concentration algorithms applied on human skin
    Klaessens, J. H. G. M.
    Noordmans, H. J.
    de Roode, R.
    Verdaasdonk, R. M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 725 - 728
  • [4] Non-invasive skin oxygenation imaging using a multi-spectral camera system: Effectiveness of various concentration algorithms applied on human skin
    Klaessens, John H. G. M.
    Noordmans, Herke Jan
    de Roode, Rowland
    Verdaasdonk, Rudolf M.
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VIII, 2009, 7174
  • [5] LED Based Sensor System for Non-Invasive Measurement of the Hemoglobin Concentration in Human Blood
    Timm, U.
    Lewis, E.
    McGrath, D.
    Kraitl, J.
    Ewald, H.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 825 - +
  • [6] Evaluation of the skin blood flow contribution to the non-invasive measurement of muscle oxygenation by near infrared spectroscopy
    Quaresima, Valentina
    Ferrari, Marco
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2006, 56 (03) : 267 - 268
  • [7] Digital imaging, spectroscopy, and liquid crystals in a hand-held, non-invasive device to determine hemoglobin concentration
    Suner, Selim
    McMurdy, John
    Jay, Gregory
    Crawford, Gregory
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2007, 15 (06) : 399 - 407