OPTIMAL CONCENTRATIONS OF GADOVIST IN T1-WEIGHTED MAGNETIC RESONANCE IMAGING: PHANTOM STUDY AND COMPUTER SIMULATION

被引:2
|
作者
Hsiao, Chia-Chi [2 ]
Chen, Po-Chou [3 ]
Pan, Huay-Ben [2 ]
Jao, Jo-Chi [1 ]
机构
[1] Kaohsiung Med Univ, Dept Med Imaging & Radiol Sci, Kaohsiung 807, Taiwan
[2] Kaohsiung Vet Gen Hosp, Dept Radiol, Kaohsiung 813, Taiwan
[3] I SHOU Univ, Dept Biomed Engn, Kaohsiung 824, Taiwan
来源
BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS | 2011年 / 23卷 / 03期
关键词
Gadovist; Spin echo; Spoiled gradient echo; Inversion recovery; Pulse sequence; CONTRAST AGENTS; GD-DTPA; BRAIN METASTASIS; PERFUSION; ANGIOGRAPHY; GADOBUTROL; DIAGNOSIS; CARCINOMA; MRI; GADOLINIUM;
D O I
10.4015/S1016237211002578
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Contrast-Enhanced Magnetic Resonance Imaging (CE-MRI) has been widely used in the diagnosis of lesions. Many contrast agents with various chemical and pharmacokinetic properties have been developed for clinical use. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) after the contrast agent administration depend on many factors, e. g. category and injected dosage of contrast agents, field strength of magnetic resonance (MR) scanner, slew rate of gradient, type of radiofrequency coil, reconstruction algorithm, pulse sequences, and so on. Gadovist is a newly developed contrast agent with high formulation of 1.0 M. It has been used in MR angiography and perfusion studies. The aim of this study is to investigate the optimal concentrations of Gadovist in MR T-1-weighted (T1W) images from phantom study and computer simulation. A phantom made of 21 test tubes with various concentrations of Gadovist (0-160 mM) was investigated. All the studies were performed on a 1.5-T clinical whole-body scanner. Four T1W pulse sequences, including two-dimensional spoiled gradient echo (2DSPGR), three-dimensional fast spoiled gradient echo (3DFSPGR), conventional spin echo (CSE), and inversion recovery (IR) were employed to produce T1W images. The CNR values were calculated from regions of interest (ROIs) of all test tubes and the optimal concentration for each pulse sequence was determined. The T-1 and T-2 values of the phantom were also measured to obtain the relaxivities (r(1) and r(2)). Afterward, the optimal concentration for each pulse sequence could be obtained from computer simulation by using the r(1) and r(2) values. The results showed that the measured optimal concentrations for 2DSPGR, 3DFSPGR, CSE and IR are 10, 20, 2.5, and 2.5 mM, respectively. The r(1) and r(2) values of the Gadovist phantom are 4.1 and 5.7 mM(-1)s(-1), respectively. The optimal concentrations obtained from computer simulation are 13.5, 22.8, 2.0, and 2.7 mM for 2DSPGR, 3DFSPGR, CSE, and IR, respectively. The optimal concentrations obtained from computer simulation and phantom study are in good agreement.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [41] Differential diagnosis between metastatic and osteoporotic vertebral fractures using sagittal T1-weighted magnetic resonance imaging
    Yamamoto, Yusuke
    Iwata, Eiichiro
    Shigematsu, Hideki
    Morita, Toshiya
    Tanaka, Masato
    Okuda, Akinori
    Masuda, Keisuke
    Ikejiri, Masaki
    Nakajima, Hiroshi
    Koizumi, Munehisa
    Tanaka, Yasuhito
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2020, 25 (05) : 763 - 769
  • [42] Gd2O3 Nanoparticles Coated with a Fluorescent Carbon Layer for Potential T1-Weighted Magnetic Resonance and Cells Imaging
    Molkenova, Anara
    Shin, Yong Cheol
    Kang, Moon Sung
    Mulikova, Tomiris
    Han, Dong-Wook
    Atabaev, Timur Sh.
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2019, 11 (06) : 813 - 817
  • [43] Multifunctional Theranostic Nanoparticles Based on Exceedingly Small Magnetic Iron Oxide Nanoparticles for T1-Weighted Magnetic Resonance Imaging and Chemotherapy
    Shen, Zheyu
    Chen, Tianxing
    Ma, Xuehua
    Ren, Wenzhi
    Zhou, Zijian
    Zhu, Guizhi
    Zhang, Ariel
    Liu, Yijing
    Song, Jibin
    Li, Zihou
    Ruan, Huimin
    Fan, Wenpei
    Lin, Lisen
    Munasinghe, Jeeva
    Chen, Xiaoyuan
    Wu, Aiguo
    ACS NANO, 2017, 11 (11) : 10992 - 11004
  • [44] Manganese-Enhanced Magnetic Resonance Imaging in Experimental Spinal Cord Injury: Correlation Between T1-Weighted Changes and Mn2+ Concentrations
    Martirosyan, Nikolay L.
    Bennett, Kevin M.
    Theodore, Nicholas
    Preul, Mark C.
    NEUROSURGERY, 2010, 66 (01) : 131 - 136
  • [45] Associating T1-Weighted and T2-Weighted Magnetic Resonance Imaging Radiomic Signatures With Preoperative Symptom Severity in Patients With Cervical Spondylotic Myelopathy
    Alan, Nima
    Zenkin, Serafettin
    Lavadi, Raj Swaroop
    Legarreta, Andrew D.
    Hudson, Joseph S.
    Fields, Daryl P.
    Agarwal, Nitin
    Mamindla, Priyadarshini
    Zhang, Murat
    Peddagangireddy, Vishal
    Puccio, Lauren
    Buell, Thomas J.
    Hamilton, D. Kojo
    Kanter, Adam S.
    Okonkwo, David O.
    Zinn, Pascal O.
    Colen, Rivka R.
    WORLD NEUROSURGERY, 2024, 184 : E137 - E143
  • [46] Detection of Prostate Cancer With Magnetic Resonance Imaging: Optimization of T1-Weighted, T2-Weighted, Dynamic-Enhanced T1-Weighted, Diffusion-Weighted Imaging Apparent Diffusion Coefficient Mapping Sequences and MR Spectroscopy, Correlated With Biopsy and Histopathological Findings
    Aydin, Hasan
    Kizilgoz, Volkan
    Tatar, Idil Gunes
    Damar, Cagri
    Ugan, Ali Riza
    Paker, Iram
    Hekimoglu, Baki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (01) : 30 - 45
  • [47] Iron(III) Coordinated Polymeric Nanomaterial: A Next-Generation Theranostic Agent for High-Resolution T1-Weighted Magnetic Resonance Imaging and Anticancer Drug Delivery
    Patra, Diptendu
    Mukherjee, Saikat
    Chakraborty, Ipsita
    Dash, Tapan K.
    Senapati, Shantibhusan
    Bhattacharyya, Rangeet
    Shunmugam, Raja
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2018, 4 (05): : 1738 - 1749
  • [48] Biocompatible iron(II)-doped carbon dots as T1-weighted magnetic resonance contrast agents and fluorescence imaging probes
    Huang, Qing
    Liu, Yue
    Zheng, Linling
    Wu, Liping
    Zhou, Zhengyu
    Chen, Jiafei
    Chen, Wei
    Zhao, Huawen
    MICROCHIMICA ACTA, 2019, 186 (08)
  • [49] Comparison of reliability of magnetic resonance imaging using cartilage and T1-weighted sequences in the assessment of the closure of the growth plates at the knee
    Kvist, Ola F. T.
    Dallora, Ana Luiza
    Nilsson, Ola
    Anderberg, Peter
    Berglund, Johan Sanmartin
    Flodmark, Carl-Erik
    Diaz, Sandra
    ACTA RADIOLOGICA OPEN, 2020, 9 (09)
  • [50] PEGylation of MnO nanoparticles via catechol-Mn chelation to improving T1-weighted magnetic resonance imaging application
    Huang, Haitao
    Yue, Tao
    Xu, Yanyun
    Xu, Ke
    Xu, Haibo
    Liu, Shiyuan
    Yu, Jiahui
    Huang, Jin
    JOURNAL OF APPLIED POLYMER SCIENCE, 2015, 132 (31)