OPTIMAL CONCENTRATIONS OF GADOVIST IN T1-WEIGHTED MAGNETIC RESONANCE IMAGING: PHANTOM STUDY AND COMPUTER SIMULATION

被引:2
|
作者
Hsiao, Chia-Chi [2 ]
Chen, Po-Chou [3 ]
Pan, Huay-Ben [2 ]
Jao, Jo-Chi [1 ]
机构
[1] Kaohsiung Med Univ, Dept Med Imaging & Radiol Sci, Kaohsiung 807, Taiwan
[2] Kaohsiung Vet Gen Hosp, Dept Radiol, Kaohsiung 813, Taiwan
[3] I SHOU Univ, Dept Biomed Engn, Kaohsiung 824, Taiwan
来源
BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS | 2011年 / 23卷 / 03期
关键词
Gadovist; Spin echo; Spoiled gradient echo; Inversion recovery; Pulse sequence; CONTRAST AGENTS; GD-DTPA; BRAIN METASTASIS; PERFUSION; ANGIOGRAPHY; GADOBUTROL; DIAGNOSIS; CARCINOMA; MRI; GADOLINIUM;
D O I
10.4015/S1016237211002578
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Contrast-Enhanced Magnetic Resonance Imaging (CE-MRI) has been widely used in the diagnosis of lesions. Many contrast agents with various chemical and pharmacokinetic properties have been developed for clinical use. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) after the contrast agent administration depend on many factors, e. g. category and injected dosage of contrast agents, field strength of magnetic resonance (MR) scanner, slew rate of gradient, type of radiofrequency coil, reconstruction algorithm, pulse sequences, and so on. Gadovist is a newly developed contrast agent with high formulation of 1.0 M. It has been used in MR angiography and perfusion studies. The aim of this study is to investigate the optimal concentrations of Gadovist in MR T-1-weighted (T1W) images from phantom study and computer simulation. A phantom made of 21 test tubes with various concentrations of Gadovist (0-160 mM) was investigated. All the studies were performed on a 1.5-T clinical whole-body scanner. Four T1W pulse sequences, including two-dimensional spoiled gradient echo (2DSPGR), three-dimensional fast spoiled gradient echo (3DFSPGR), conventional spin echo (CSE), and inversion recovery (IR) were employed to produce T1W images. The CNR values were calculated from regions of interest (ROIs) of all test tubes and the optimal concentration for each pulse sequence was determined. The T-1 and T-2 values of the phantom were also measured to obtain the relaxivities (r(1) and r(2)). Afterward, the optimal concentration for each pulse sequence could be obtained from computer simulation by using the r(1) and r(2) values. The results showed that the measured optimal concentrations for 2DSPGR, 3DFSPGR, CSE and IR are 10, 20, 2.5, and 2.5 mM, respectively. The r(1) and r(2) values of the Gadovist phantom are 4.1 and 5.7 mM(-1)s(-1), respectively. The optimal concentrations obtained from computer simulation are 13.5, 22.8, 2.0, and 2.7 mM for 2DSPGR, 3DFSPGR, CSE, and IR, respectively. The optimal concentrations obtained from computer simulation and phantom study are in good agreement.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [31] Carotid plaque signal differences among four kinds of T1-weighted magnetic resonance imaging techniques: A histopathological correlation study
    Saito, Ayumi
    Sasaki, Makoto
    Ogasawara, Kuniaki
    Kobayashi, Masakazu
    Hitomi, Jiro
    Narumi, Shinsuke
    Ohba, Hideki
    Yamaguchi, Mao
    Kudo, Kohsuke
    Terayama, Yasuo
    NEURORADIOLOGY, 2012, 54 (11) : 1187 - 1194
  • [32] Improving acute demyelinating lesion detection: which T1-weighted magnetic resonance acquisition is more sensitive to gadolinium enhancement?
    Faria do Amaral, Lazaro Luiz
    Fragoso, Diego Cardoso
    do Rocha, Antonio Jose
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2019, 77 (07) : 485 - 492
  • [33] Zwitterion-coated ultrasmall iron oxide nanoparticles for enhanced T1-weighted magnetic resonance imaging applications
    Ma, Dan
    Chen, Jingwen
    Luo, Yu
    Wang, Han
    Shi, Xiangyang
    JOURNAL OF MATERIALS CHEMISTRY B, 2017, 5 (35) : 7267 - 7273
  • [34] Glioma grading using an optimized T1-weighted dynamic contrast-enhanced magnetic resonance imaging paradigm
    Abdi, Aza Ismail
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01)
  • [35] Impact of time-of-day on brain morphometric measures derived from T1-weighted magnetic resonance imaging
    Trefler, Aaron
    Sadeghi, Neda
    Thomas, Adam G.
    Pierpaoli, Carlo
    Baker, Chris I.
    Thomas, Cibu
    NEUROIMAGE, 2016, 133 : 41 - 52
  • [36] High Spatial Resolution, Respiratory-Gated, T1-Weighted Magnetic Resonance Imaging of the Liver and the Biliary Tract During the Hepatobiliary Phase of Gadoxetic Acid-Enhanced Magnetic Resonance Imaging
    Lee, Eun Sun
    Lee, Jeong Min
    Yu, Mi Hye
    Shin, Cheong-il
    Woo, Hyun Sik
    Joo, Ijin
    Stemmer, Alto
    Han, Joon Koo
    Choi, Byung Ihn
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (03) : 360 - 366
  • [37] Facile synthesis of manganese silicate nanoparticles for pH/GSH-responsive T1-weighted magnetic resonance imaging
    Li, X. W.
    Zhao, W. R.
    Liu, Y. J.
    Liu, X. H.
    Shi, P.
    Li, Y. S.
    Shi, J. L.
    JOURNAL OF MATERIALS CHEMISTRY B, 2016, 4 (24) : 4313 - 4321
  • [38] Temporal and spatial characteristics of the area at risk investigated using computed tomography and T1-weighted magnetic resonance imaging
    van der Pals, Jesper
    Hammer-Hansen, Sophia
    Nielles-Vallespin, Sonia
    Kellman, Peter
    Taylor, Joni
    Kozlov, Shawn
    Hsu, Li-Yueh
    Chen, Marcus Y.
    Arai, Andrew E.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (11) : 1232 - 1240
  • [39] A voxel based comparative analysis using magnetization transfer imaging and T1-weighted magnetic resonance imaging in progressive supranuclear palsy
    Sandhya, Mangalore
    Saini, Jitender
    Pasha, Shaik Afsar
    Yadav, Ravi
    Pal, Pramod Kumar
    ANNALS OF INDIAN ACADEMY OF NEUROLOGY, 2014, 17 (02) : 193 - 198
  • [40] T1-weighted hyperintensity in basal ganglia at brain magnetic resonance imaging: Are different pathologies sharing a common mechanism?
    Hernandez, EH
    Valentini, MC
    Discalzi, G
    NEUROTOXICOLOGY, 2002, 23 (06) : 669 - 674