OPTIMAL CONCENTRATIONS OF GADOVIST IN T1-WEIGHTED MAGNETIC RESONANCE IMAGING: PHANTOM STUDY AND COMPUTER SIMULATION

被引:2
|
作者
Hsiao, Chia-Chi [2 ]
Chen, Po-Chou [3 ]
Pan, Huay-Ben [2 ]
Jao, Jo-Chi [1 ]
机构
[1] Kaohsiung Med Univ, Dept Med Imaging & Radiol Sci, Kaohsiung 807, Taiwan
[2] Kaohsiung Vet Gen Hosp, Dept Radiol, Kaohsiung 813, Taiwan
[3] I SHOU Univ, Dept Biomed Engn, Kaohsiung 824, Taiwan
来源
BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS | 2011年 / 23卷 / 03期
关键词
Gadovist; Spin echo; Spoiled gradient echo; Inversion recovery; Pulse sequence; CONTRAST AGENTS; GD-DTPA; BRAIN METASTASIS; PERFUSION; ANGIOGRAPHY; GADOBUTROL; DIAGNOSIS; CARCINOMA; MRI; GADOLINIUM;
D O I
10.4015/S1016237211002578
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Contrast-Enhanced Magnetic Resonance Imaging (CE-MRI) has been widely used in the diagnosis of lesions. Many contrast agents with various chemical and pharmacokinetic properties have been developed for clinical use. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) after the contrast agent administration depend on many factors, e. g. category and injected dosage of contrast agents, field strength of magnetic resonance (MR) scanner, slew rate of gradient, type of radiofrequency coil, reconstruction algorithm, pulse sequences, and so on. Gadovist is a newly developed contrast agent with high formulation of 1.0 M. It has been used in MR angiography and perfusion studies. The aim of this study is to investigate the optimal concentrations of Gadovist in MR T-1-weighted (T1W) images from phantom study and computer simulation. A phantom made of 21 test tubes with various concentrations of Gadovist (0-160 mM) was investigated. All the studies were performed on a 1.5-T clinical whole-body scanner. Four T1W pulse sequences, including two-dimensional spoiled gradient echo (2DSPGR), three-dimensional fast spoiled gradient echo (3DFSPGR), conventional spin echo (CSE), and inversion recovery (IR) were employed to produce T1W images. The CNR values were calculated from regions of interest (ROIs) of all test tubes and the optimal concentration for each pulse sequence was determined. The T-1 and T-2 values of the phantom were also measured to obtain the relaxivities (r(1) and r(2)). Afterward, the optimal concentration for each pulse sequence could be obtained from computer simulation by using the r(1) and r(2) values. The results showed that the measured optimal concentrations for 2DSPGR, 3DFSPGR, CSE and IR are 10, 20, 2.5, and 2.5 mM, respectively. The r(1) and r(2) values of the Gadovist phantom are 4.1 and 5.7 mM(-1)s(-1), respectively. The optimal concentrations obtained from computer simulation are 13.5, 22.8, 2.0, and 2.7 mM for 2DSPGR, 3DFSPGR, CSE, and IR, respectively. The optimal concentrations obtained from computer simulation and phantom study are in good agreement.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [21] Exceedingly Small Magnetic Iron Oxide Nanoparticles for T1-Weighted Magnetic Resonance Imaging and Imaging-Guided Therapy of Tumors
    Yang, Jing
    Feng, Jie
    Yang, Sugeun
    Xu, Yikai
    Shen, Zheyu
    SMALL, 2023, 19 (49)
  • [22] Biodegradable and biocompatible exceedingly small magnetic iron oxide nanoparticles for T1-weighted magnetic resonance imaging of tumors
    Lu, Xuanyi
    Zhou, Huimin
    Liang, Zhiyu
    Feng, Jie
    Lu, Yudie
    Huang, Lin
    Qiu, Xiaozhong
    Xu, Yikai
    Shen, Zheyu
    JOURNAL OF NANOBIOTECHNOLOGY, 2022, 20 (01)
  • [23] Evaluation of gadolinium-enhanced T1-weighted magnetic resonance imaging in the preoperative assessment of local staging in rectal cancer
    Jao, S. -Y.
    Yang, B. -Y.
    Weng, H. -H
    Yeh, C. -H.
    Lee, L. -W.
    COLORECTAL DISEASE, 2010, 12 (11) : 1139 - 1148
  • [24] Identification of Alzheimer's disease using a convolutional neural network model based on T1-weighted magnetic resonance imaging
    Bae, Jong Bin
    Lee, Subin
    Jung, Wonmo
    Park, Sejin
    Kim, Weonjin
    Oh, Hyunwoo
    Han, Ji Won
    Kim, Grace Eun
    Kim, Jun Sung
    Kim, Jae Hyoung
    Kim, Ki Woong
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [25] Diffusion-weighted magnetic resonance imaging for the diagnosis of giant cell arteritis: a comparison with T1-weighted black-blood imaging
    Seitz, Luca
    Bucher, Susana
    Butikofer, Lukas
    Maurer, Britta
    Bonel, Harald M.
    Wagner, Franca
    Lotscher, Fabian
    Seitz, Pascal
    RHEUMATOLOGY, 2023, : 1403 - 1410
  • [26] Hyperintensity in the Dentate Nucleus on Nonenhanced T1-Weighted Magnetic Resonance Imaging Suggests Dechelation of Contrast Agents
    Jessome, Rebecca
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2016, 47 (01) : 86 - 91
  • [27] Fatty corner lesions in T1-weighted magnetic resonance imaging as an alternative to sacroiliitis for diagnosis of axial spondyloarthritis
    Ho Yin Chung
    Rachel Sze Wan Yiu
    Shirley Chiu Wai Chan
    Kam Ho Lee
    Chak Sing Lau
    BMC Rheumatology, 3
  • [28] Application of T1-weighted BLADE sequence to abdominal magnetic resonance imaging of young children: a comparison with turbo spin echo sequence
    Choi, Kyu Sung
    Choi, Young Hun
    Cheon, Jung-Eun
    Kim, Woo Sun
    Kim, In One
    ACTA RADIOLOGICA, 2020, 61 (10) : 1406 - 1413
  • [29] Ultrasmall water-soluble metal-iron oxide nanoparticles as T1-weighted contrast agents for magnetic resonance imaging
    Zeng, Leyong
    Ren, Wenzhi
    Zheng, Jianjun
    Cui, Ping
    Wu, Aiguo
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2012, 14 (08) : 2631 - 2636
  • [30] High-Intensity Signals in Coronary Plaques on Noncontrast T1-Weighted Magnetic Resonance Imaging as a Novel Determinant of Coronary Events
    Noguchi, Teruo
    Kawasaki, Tomohiro
    Tanaka, Atsushi
    Yasuda, Satoshi
    Goto, Yoichi
    Ishihara, Masaharu
    Nishimura, Kunihiro
    Miyamoto, Yoshihiro
    Node, Koichi
    Koga, Nobuhiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (10) : 989 - 999