Validation study on avermectine residues in foodstuffs

被引:34
作者
Giannetti, L. [1 ]
Giorgi, A. [1 ]
Necci, F. [1 ]
Ferretti, G. [1 ]
Buiarelli, F. [2 ]
Neri, B. [1 ]
机构
[1] Ist Zooprofilatt Sperimentale Reg Lazio & Toscana, I-00178 Rome, Italy
[2] Univ Roma La Sapienza, Dipartimento Chim, I-00185 Rome, Italy
关键词
Avermectines; Residue; Validation; Liquid chromatography; Fluorescence; TANDEM MASS-SPECTROMETRY; DERIVATIZATION; CONFIRMATION; MILBEMYCINS; IVERMECTIN; MOXIDECTIN; EMAMECTIN; ABAMECTIN; MILK;
D O I
10.1016/j.aca.2010.12.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Avermectines are antiparasitic agents widely used as veterinary drugs for food producing animals. The European Community, due to their side effects, limited the use of these molecules establishing maximum residue limits (MRLs) in some foods. A validated qualitative and quantitative high performance liquid chromatography method with fluorescence detection (HPLC-FL) is presented for the simultaneous determination of ivermectin (IVM), abemectin (ABA), moxidectin (MOX), eprinomectin (EPR), doramectin (DOR) and emamectin (EMA) in foodstuffs (muscle, eggs and milk). Samples were extracted with acetonitrile, purified with liquid-liquid extraction (LLE), and analysed by HLPC-FL previous derivatization with trifluoroacetic anhydride (TFAA) in presence of 1-methyl-imidazole (MI) and acetic acid. To date, the presented method is the first validated for the matrix eggs, and in accordance with the requirements set by Commission Decision 2002/657/EC. Recoveries of the methods, calculated spiking the samples in the range 5.0-100.0 mu g kg(-1), were 64-83% for muscle, 65-89% for milk and 63-84% for eggs. The precision (CV) ranged between 9.2 and 17.1% for muscle, 9.9 and 16.6% for milk and from 9.4 to 17.4% for eggs. Linearity for the six analytes was calculated from 5.0 to 200.0 mu g kg(-1). The main advantages of the presented method are its rapidity, the specificity, the good precision and recovery that make it very suitable to the detection and determination of avermectines. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:11 / 15
页数:5
相关论文
共 12 条
[1]  
[Anonymous], [No title captured]
[2]  
[Anonymous], OFFICIAL J EUROPEA L
[3]  
[Anonymous], 2005, ISO/IEC 17025: General requirements for the competence of testing and calibration laboratories
[4]   The derivatisation of avermectins and milbemycins in milk: New insights and improvement of the procedure [J].
Berendsen, Bjorn J. A. ;
Mulder, Patrick P. J. ;
van Rhijn, Hans A. .
ANALYTICA CHIMICA ACTA, 2007, 585 (01) :126-133
[5]   Trace analysis of endectocides in milk by high performance liquid chromatography with fluorescence detection [J].
Cerkvenik-Flajs, Vesna ;
Milcinski, Luka ;
Suessinger, Adica ;
Hodoscek, Lena ;
Danaher, Martin ;
Antonic, Jan .
ANALYTICA CHIMICA ACTA, 2010, 663 (02) :165-171
[6]   Development and optimisation of an improved derivatisation procedure for the determination of avermectins and milbemycins in bovine liver [J].
Danaher, M ;
O'Keeffe, M ;
Glennon, JD ;
Howells, L .
ANALYST, 2001, 126 (05) :576-580
[7]   Review of methodology for the determination of macrocyclic lactone residues in biological matrices [J].
Danaher, Martin ;
Howells, Laurence C. ;
Crooks, Steven R. H. ;
Cerkvenik-Flajs, Vesna ;
O'Keefe, Michael .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (02) :175-203
[8]   Positive and negative electrospray LC-MS-MS methods for quantitation of the antiparasitic endectocide drugs, abamectin, doramectin, emamectin, eprinomectin, ivermectin, moxidectin and selamectin in milk [J].
Durden, David A. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2) :134-146
[9]   Fast separation liquid chromatography-tandem mass spectrometry for the confirmation and quantitative analysis of avermectin residues in food [J].
Hernando, M. D. ;
Suarez-Barcena, J. M. ;
Bueno, M. J. M. ;
Garcia-Reyes, J. F. ;
Fernandez-Alba, A. R. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1155 (01) :62-73
[10]   AVERMECTINS, A NOVEL CLASS OF COMPOUNDS - IMPLICATIONS FOR USE IN ARTHROPOD PEST-CONTROL [J].
LASOTA, JA ;
DYBAS, RA .
ANNUAL REVIEW OF ENTOMOLOGY, 1991, 36 :91-117