Comparative Diagnostic Performance of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Kit for the Rapid Detection of SARS-CoV-2

被引:2
作者
Domnich, Alexander [1 ]
Orsi, Andrea [1 ,2 ]
Panatto, Donatella [2 ]
De Pace, Vanessa [1 ]
Ricucci, Valentina [1 ]
Caligiuri, Patrizia [1 ]
Guarona, Giulia [1 ]
Chessa, Valerio [1 ]
Ferone, Diego [3 ,4 ]
Boccotti, Simona [1 ,2 ]
Bruzzone, Bianca [1 ]
Icardi, Giancarlo [1 ,2 ]
机构
[1] San Martino Policlin Hosp, IRCCS Oncol & Neurosci, Hyg Unit, I-16132 Genoa, Italy
[2] Univ Genoa, Dept Hlth Sci, I-16132 Genoa, Italy
[3] Univ Genoa, Dept Internal Med & Med Specialties, I-16132 Genoa, Italy
[4] San Martino Policlin Hosp, IRCCS Oncol & Neurosci, Endocrinol Unit, I-16132 Genoa, Italy
基金
欧盟地平线“2020”;
关键词
COVID-19; SARS-CoV-2; RT-LAMP; RT-PCR; diagnostic accuracy; COVID-19;
D O I
10.3390/pathogens10121629
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Although the reverse transcription-polymerase chain reaction (RT-PCR) is considered a standard-of-care assay for the laboratory diagnosis of SARS-CoV-2, several limitations of this method have been described. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is an alternative molecular assay and is potentially able to overcome some intrinsic shortcomings of RT-PCR. In this study, we evaluated the diagnostic performance of the novel HG COVID-19 RT-LAMP assay. In this retrospective analysis, a total of 400 routinely collected leftover nasopharyngeal samples with a known RT-PCR result were tested by means of the HG COVID-19 RT-LAMP assay. The overall sensitivity and specificity values of HG COVID-19 RT-LAMP versus RT-PCR were 97.0% (95% CI: 93.6-98.9%) and 98.5% (95% CI: 95.7-99.7%), respectively. Inter-assay agreement was almost perfect (kappa = 0.96). Concordance was perfect in samples with high viral loads (cycle threshold < 30). The average time to a positive result on RT-LAMP was 17 min. HG COVID-19 RT-LAMP is a reliable molecular diagnostic kit for detecting SARS-CoV-2, and its performance is comparable to that of RT-PCR. Shorter turnaround times and the possibility of performing molecular diagnostics in the point-of-care setting make it a valuable option for facilities without sophisticated laboratory equipment.
引用
收藏
页数:9
相关论文
共 50 条
[41]   Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Assay for Rapid Diagnosis of Sugarcane yellow leaf virus in Sugarcane [J].
Anandakumar, L. ;
Bagyalakshmi, K. ;
Nithya, K. ;
Parameswari, B. ;
Viswanathan, R. .
SUGAR TECH, 2018, 20 (06) :708-716
[42]   Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Assay for Rapid Diagnosis of Sugarcane yellow leaf virus in Sugarcane [J].
L. Anandakumar ;
K. Bagyalakshmi ;
K. Nithya ;
B. Parameswari ;
R. Viswanathan .
Sugar Tech, 2018, 20 :708-716
[43]   Rapid molecular detection of Senecavirus A based on reverse transcription loop-mediated isothermal amplification (RT-LAMP) and CRISPR/Cas12a [J].
Jiang, Chenghui ;
Wang, Huibao ;
Guo, Rongxia ;
Yang, Rui ;
Li, Xiaoming ;
Liu, Ping ;
Wang, Jing ;
Yang, Jincai ;
Chang, Yanyan ;
Zeng, Qiaoying .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2025, 13
[44]   Reverse transcriptase loop-mediated isothermal amplification (RT-LAMP)-based diagnosis: A potential alternative to quantitative real-time PCR based detection of the novel SARS-COV-2 virus [J].
Haq, Farhan ;
Sharif, Salmaan ;
Khurshid, Adnan ;
Ikram, Aamer ;
Shabbir, Imran ;
Salman, Muhammad ;
Ahad, Abdul ;
Rana, Muhammad Suleman ;
Raja, Aroosha ;
Badar, Nazish ;
Tashkandi, Hanaa ;
Al Amri, Turki ;
Azhar, Esam, I ;
Almuhayawi, Mohammed S. ;
Harakeh, Steve ;
Malik, Muhammad Faraz Arshad .
SAUDI JOURNAL OF BIOLOGICAL SCIENCES, 2021, 28 (01) :942-947
[45]   Preliminary optimisation of a simplified sample preparation method to permit direct detection of SARS-CoV-2 within saliva samples using reverse-transcription loop-mediated isothermal amplification (RT-LAMP) [J].
Howson, Emma L. A. ;
Kidd, Stephen P. ;
Armson, Bryony ;
Goring, Alice ;
Sawyer, Jason ;
Cassar, Claire ;
Cross, David ;
Lewis, Tom ;
Hockey, Jess ;
Rivers, Samantha ;
Cawthraw, Saira ;
Banyard, Ashley ;
Anderson, Paul ;
Rahou, Sabah ;
Andreou, Michael ;
Morant, Nick ;
Clark, Duncan ;
Walsh, Charlotte ;
Laxman, Shailen ;
Houghton, Rebecca ;
Slater-Jefferies, Joanne ;
Costello, Paula ;
Brown, Ian ;
Cortes, Nicholas ;
Godfrey, Keith M. ;
Fowler, Veronica L. .
JOURNAL OF VIROLOGICAL METHODS, 2021, 289
[46]   One-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) for detection of tomato torrado virus [J].
Marta Budziszewska ;
Przemysław Wieczorek ;
Aleksandra Obrępalska-Stęplowska .
Archives of Virology, 2016, 161 :1359-1364
[47]   Detection of Middle East respiratory syndrome coronavirus using reverse transcription loop-mediated isothermal amplification (RT-LAMP) [J].
Kazuya Shirato ;
Takuya Yano ;
Syouhei Senba ;
Shigehiro Akachi ;
Takashi Kobayashi ;
Takamichi Nishinaka ;
Tsugunori Notomi ;
Shutoku Matsuyama .
Virology Journal, 11
[48]   Detection of Middle East respiratory syndrome coronavirus using reverse transcription loop-mediated isothermal amplification (RT-LAMP) [J].
Shirato, Kazuya ;
Yano, Takuya ;
Senba, Syouhei ;
Akachi, Shigehiro ;
Kobayashi, Takashi ;
Nishinaka, Takamichi ;
Notomi, Tsugunori ;
Matsuyama, Shutoku .
VIROLOGY JOURNAL, 2014, 11
[49]   One-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) for detection of tomato torrado virus [J].
Budziszewska, Marta ;
Wieczorek, Przemysaw ;
Obrepalska-Steplowska, Aleksandra .
ARCHIVES OF VIROLOGY, 2016, 161 (05) :1359-1364
[50]   A Palm Germ-Radar (PaGeR) for rapid and simple COVID-19 detection by reverse transcription loop-mediated isothermal amplification (RT-LAMP) [J].
Ge, Anle ;
Liu, Fengyi ;
Teng, Xindong ;
Cui, Chaojie ;
Wu, Fei ;
Liu, Wenjing ;
Liu, Yang ;
Chen, Xiaoguang ;
Xu, Jian ;
Ma, Bo .
BIOSENSORS & BIOELECTRONICS, 2022, 200