In vivo evaluation of a novel, wrist-mounted arterial pressure sensing device versus the traditional hand-held tonometer

被引:12
作者
Vardoulis, Orestis [1 ,2 ]
Saponas, T. Scott [1 ]
Morris, Dan [1 ]
Villar, Nicolas [1 ]
Smith, Greg [1 ]
Patel, Shwetak [1 ,3 ]
Tan, Desney [1 ]
机构
[1] Microsoft Res, Redmond, WA 98052 USA
[2] Ecole Polytech Fed Lausanne, Lab Hemodynam & Cardiovasc Technol, Lausanne, Switzerland
[3] Univ Washington, Seattle, WA 98195 USA
关键词
Arterial tonometry; Pressure sensor; Radial artery; Arterial stiffness; PULSE-WAVE ANALYSIS; SIGNAL QUALITY ESTIMATION; AUGMENTATION INDEX; BLOOD-PRESSURE; PERIPHERAL PULSE; REPRODUCIBILITY; VELOCITY; TIME; STIFFNESS;
D O I
10.1016/j.medengphy.2016.06.022
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although hemodynamic parameters can be assessed non-invasively, state-of-the-art non-invasive systems generally require an expert operator and are not applicable for ambulatory measurements. These limitations have restricted our understanding of the continuous behavior of hemodynamic parameters. In this manuscript, we introduce a novel wrist-mounted device that incorporates an array of pressure sensors which can be used to extract arterial waveforms and relevant pulse wave analysis biomarkers. In vivo evaluation is performed with Bland-Altman analysis to compare the novel sensor to a gold-standard hand-held tonometer by assessing their reproducibility and agreement in peripheral augmentation index (AIx) estimation at the radial artery. Arterial waves from 28 randomly selected participants were recorded in a controlled environment. Initially we assess the reproducibility of AIx results for both devices. The intra-class correlation coefficient (ICC) and mean difference +/- SD were [0.913, 0.033 +/- 0.048] and [0.859, 0.039 +/- 0.076] for the hand-held and the wrist-mounted tonometer respectively. We then show that the AIx values derived from the novel tonometer have good agreement, accuracy, and precision when compared against the AIx values derived from the reference hand-held tonometer (ICC 0.927, mean difference 0.026 +/- 0.049). In conclusion, we have presented evidence that the new wrist-mounted arterial pressure sensor records arterial waveforms that can be processed to yield AIx values that are in good agreement with its traditional hand-held counterpart. (C) 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1063 / 1069
页数:7
相关论文
共 28 条
  • [1] Validity of a Novel Wristband Tonometer for Measuring Central Hemodynamics and Augmentation Index
    Beck, Darren T.
    Martin, Jeffrey S.
    Nichols, Wilmer W.
    Gurovich, Alvaro N.
    Braith, Randy W.
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2014, 27 (07) : 926 - 931
  • [2] Tonometric Arterial Pulse Sensor With Noise Cancellation
    Ciaccio, Edward J.
    Drzewiecki, Gary M.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (10) : 2388 - 2396
  • [3] Detection of motion artifact patterns in photoplethysmographic signals based on time and period domain analysis
    Couceiro, R.
    Carvalho, P.
    Paiva, R. P.
    Henriques, J.
    Muehlsteff, J.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2014, 35 (12) : 2369 - 2388
  • [4] Reproducibility of radial pulse wave analysis in healthy subjects
    Filipovsky, J
    Svobodová, V
    Pecen, L
    [J]. JOURNAL OF HYPERTENSION, 2000, 18 (08) : 1033 - 1040
  • [5] Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation
    Karlen, W.
    Kobayashi, K.
    Ansermino, J. M.
    Dumont, G. A.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2012, 33 (10) : 1617 - 1629
  • [6] NONINVASIVE DETERMINATION OF AGE-RELATED-CHANGES IN THE HUMAN ARTERIAL PULSE
    KELLY, R
    HAYWARD, C
    AVOLIO, A
    OROURKE, M
    [J]. CIRCULATION, 1989, 80 (06) : 1652 - 1659
  • [7] KELLY R, 1988, AUST NZ J MED, V18, P374
  • [8] Radial augmentation index: A useful and easily obtainable parameter for vascular aging
    Kohara, K
    Tabara, Y
    Oshiumi, A
    Miyawaki, Y
    Kobayashi, T
    Miki, T
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (01) : 11S - 14S
  • [9] Arterial and cardiac aging: Major shareholders in cardiovascular disease enterprises Part I: Aging arteries: A "set up" for vascular disease
    Lakatta, EG
    Levy, D
    [J]. CIRCULATION, 2003, 107 (01) : 139 - 146
  • [10] Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter
    Li, Q.
    Mark, R. G.
    Clifford, G. D.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2008, 29 (01) : 15 - 32