Beyond flux: Total corneal oxygen consumption as an index of corneal oxygenation during contact lens wear

被引:63
作者
Brennan, NA [1 ]
机构
[1] Brennan Consultants, Auburn Village 3122, Australia
关键词
cornea; contact lens; oxygen transmissibility; oxygen consumption; silicone-hydrogel;
D O I
10.1097/01.opx.0000168560.10861.ae
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of this study is to compute total corneal oxygen consumption during contact lens wear and consider the concept as an index for describing corneal oxygenation during contact lens wear as opposed to flux, partial pressure, or Dk/t. Method. Estimates of total corneal oxygen consumption were generated using a previously described eight-layer model based on oxygen diffusion equations and using contemporary estimates of tear and corneal layer thicknesses. Relative consumption, expressed as %Q (percentage of normal consumption without contact lens wear), was also calculated for daily wear and continuous wear modes, thereby providing an index of the chronic hypoxic effect of contact lens wear. Results. Corneal oxygen consumption is calculated to converge to the same value of 44.8 nL/cm(3)/sec above a Dk/t of approximately 20 and 300 x 10(-9) (cm/sec)(mL0(2)/mL/mm Hg) for the open and closed eye scenarios, respectively. Lenses with Dk/t values of 15 and 50 x 10(-9) (cm/sec)(mL0(2)/mL/mm Hg) allow about 96% of normal long-term total oxygen consumption without a contact lens in place for daily wear and continuous wear, respectively. Conclusion. Total corneal oxygen consumption is based on physical parameters, represents a direct index of corneal oxygen metabolism and thus cellular energy (ATP) production, allows direct comparison between two lenses or a lens and nonlens-wearing state, and eliminates the ambiguity of other measures, thereby providing an attractive means of describing corneal oxygenation.
引用
收藏
页码:467 / 472
页数:6
相关论文
共 35 条
  • [1] BERGENSKE P, 2004, OPTOMETRY VISION SCI, V81, P78
  • [2] Bonanno JA, 2002, INVEST OPHTH VIS SCI, V43, P371
  • [3] A model of oxygen flux through contact lenses
    Brennan, NA
    [J]. CORNEA, 2001, 20 (01) : 104 - 108
  • [4] Brennan NA, 2004, CLIN CONTACT LENS PR, P41
  • [5] Brennan Noel A, 2005, Clin Exp Optom, V88, P103
  • [6] CORNEAL PATHOPHYSIOLOGY WITH CONTACT-LENS WEAR
    BRUCE, AS
    BRENNAN, NA
    [J]. SURVEY OF OPHTHALMOLOGY, 1990, 35 (01) : 25 - 58
  • [7] CARNEY L G, 1988, CLAO Journal, V14, P151
  • [8] Effects of daily and overnight wear of a novel hyper oxygen-transmissible soft contact lens on bacterial binding and corneal epithelium - A 13-month clinical trial
    Cavanagh, HD
    Ladage, PM
    Li, SL
    Yamamoto, K
    Molai, M
    Ren, DH
    Petroll, WM
    Jester, JV
    [J]. OPHTHALMOLOGY, 2002, 109 (11) : 1957 - 1969
  • [9] Biological oxygen apparent transmissibility of hydrogel contact lenses with and without organosilicon moieties
    Compañ, V
    López-Alemany, A
    Riande, E
    Refojo, MF
    [J]. BIOMATERIALS, 2004, 25 (02) : 359 - 365
  • [10] Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    Doughty, MJ
    Zaman, ML
    [J]. SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) : 367 - 408