Endoscopic optical coherence tomography for imaging the tympanic membrane

被引:4
|
作者
Burkhardt, Anke [1 ]
Walther, Julia [1 ]
Cimalla, Peter [1 ]
Bornitz, Matthias [2 ]
Koch, Edmund [1 ]
机构
[1] Tech Univ Dresden, Dept Clin Sensoring & Monitoring, Fac Med Carl Gustav Carus, Fetscherstr 74, D-01307 Dresden, Germany
[2] Tech Univ Dresden, Fac Med, Dept Otolaryngol, D-01307 Dresden, Germany
来源
OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES V | 2011年 / 8091卷
关键词
Endoscopic optical coherence tomography; tympanic membrane; otitis media; SPECTRAL-DOMAIN; IN-VIVO;
D O I
10.1117/12.889734
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography (OCT) is an imaging modality that enables micrometer-scale contactless subsurface imaging of biological tissue. Endoscopy, as another imaging method, has the potential of imaging tubular organs and cavities and therefore has opened up several application areas not accessible before. The combination of OCT and endoscopy uses the advantages of both methods and consequently allows additional imaging of structures beneath surfaces inside cavities. Currently, visual investigations on the surface of the human tympanic membrane are possible but only with expert eyes. up to now, visual imaging of the outer ear up to the tympanic membrane can be carried out by an otoscope, an operating microscope or an endoscope. In contrast to these devices, endoscopy has the advantage of imaging the whole tympanic membrane with one view. The intention of this research is the development of an endoscopic optical coherence tomography (EOCT) device for imaging the tympanic membrane depth-resolved and structures behind it. Detection of fluids in the middle ear, which function as an indicator for otitis media, could help to avoid the application of antibiotics. It is possible to detect a congeries of fluids with the otoscope but the ambition is to the early detection by OCT. The developed scanner head allows imaging in working distances in the range from zero up to 5 mm with a field of view of 2 mm. In the next step, the scanner head should be improved to increase the working distance and the field of view.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Three-dimensional Imaging with an Endoscopic Optical Coherence Tomography System for Detection of Airway Stenosis
    Kwon, Daa Young
    Oak, Chulho
    Ahn, Yeh-Chan
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2019, 30 (06) : 243 - 248
  • [22] Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology
    Tsai, Tsung-Han
    Potsaid, Benjamin
    Tao, Yuankai K.
    Jayaraman, Vijaysekhar
    Jiang, James
    Heim, Peter J. S.
    Kraus, Martin F.
    Zhou, Chao
    Hornegger, Joachim
    Mashimo, Hiroshi
    Cable, Alex E.
    Fujimoto, James G.
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (07): : 1119 - 1132
  • [23] Integrated Optical Coherence Tomography and Optical Coherence Microscopy Imaging of Human Pathology
    Lee, Hsiang-Chieh
    Zhou, Chao
    Wang, Yihong
    Aguirre, Aaron D.
    Tsai, Tsung-Han
    Cohen, David W.
    Connolly, James L.
    Fujimoto, James G.
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XVII, 2010, 7570
  • [24] Detection of tympanic membrane movement using film patch with integrated strain gauge, assessed by optical coherence tomography: experimental study
    Just, T.
    Zehlicke, T.
    Specht, O.
    Sass, W.
    Punke, C.
    Schmidt, W.
    Lankenau, E.
    Behrend, D.
    Pau, H. W.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2011, 125 (05) : 467 - 473
  • [25] Multimodal optical imaging with multiphoton microscopy and optical coherence tomography
    Tang, Shuo
    Zhou, Yifeng
    Ju, Myeong Jin
    JOURNAL OF BIOPHOTONICS, 2012, 5 (5-6) : 396 - 403
  • [26] Optical Coherence Tomography for Imaging the Middle and Inner Ears: A Technical Review
    Ramier, Antoine
    Rosowski, John J.
    Yun, Seok-Hyun
    TO THE EAR AND BACK AGAIN - ADVANCES IN AUDITORY BIOPHYSICS, 2018, 1965
  • [27] Fiber optic tunable probe for endoscopic optical coherence tomography
    Aljasem, Khaled
    Werber, Armin
    Seifert, Andreas
    Zappe, Hans
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2008, 10 (04):
  • [28] Multimodality endoscopic optical coherence tomography and fluorescence imaging technology for visualization of layered architecture and subsurface microvasculature
    Li, Yan
    Jing, Joseph
    Yu, Junxiao
    Zhang, Buyun
    Huo, Tiancheng
    Yang, Qiang
    Chen, Zhongping
    OPTICS LETTERS, 2018, 43 (09) : 2074 - 2077
  • [29] In vivo bladder imaging with microelectromechanical systems-based endoscopic spectral domain optical coherence tomography
    Wang, Zhenguo
    Lee, Christopher S. D.
    Waltzer, Wayne C.
    Liu, Jingxuan
    Xie, Huikai
    Yuan, Zhijia
    Pan, Yingtian
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (03)
  • [30] Tunable endoscopic MEMS-probe for optical coherence tomography
    Aljasem, K.
    Werber, A.
    Zappe, H.
    2007 IEEE/LEOS INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS, 2007, : 8 - 9