A radial adaptive filter for metal artifact reduction

被引:10
作者
Bal, V [1 ]
Celik, H [1 ]
Subramanyan, K [1 ]
Eck, K [1 ]
Spies, L [1 ]
机构
[1] Philips Res Labs, D-52066 Aachen, Germany
来源
Medical Imaging 2005: Image Processing, Pt 1-3 | 2005年 / 5747卷
关键词
computed tomography; metal artifacts; adaptive filtering; structure tensor;
D O I
10.1117/12.593095
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
High-density objects, such as metal prostheses or surgical clips, generate streak-like artifacts in CT images. We designed a, radial adaptive filter, which directly operates on the corrupted reconstructed image, to effectively and efficiently reduce such artifacts. The filter adapts to the severity of local artifacts to preserve spatial resolution as much as possible. The widths and direction of the filter are derived from the local structure tensor. Visual inspection shows that this novel radial adaptive filter is superior with respect to existing methods in the case of mildly distorted images. In the presence of strong artifacts we propose a, hybrid approach. An image, corrected with a, standard method, which performs well oil images with regions of severe artifacts, is fused with an adaptively filtered clone to combine the strengths of both methods.
引用
收藏
页码:2075 / 2082
页数:8
相关论文
共 10 条
[1]  
Forstner W., 1987, P ISPRS INT C FAST P, P281
[2]   AN ALGORITHM FOR THE REDUCTION OF METAL CLIP ARTIFACTS IN CT RECONSTRUCTIONS [J].
GLOVER, GH ;
PELC, NJ .
MEDICAL PHYSICS, 1981, 8 (06) :799-807
[3]   Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT [J].
Kachelriess, M ;
Watzke, O ;
Kalender, WA .
MEDICAL PHYSICS, 2001, 28 (04) :475-490
[4]   REDUCTION OF CT ARTIFACTS CAUSED BY METALLIC IMPLANTS [J].
KALENDER, WA ;
HEBEL, R ;
EBERSBERGER, J .
RADIOLOGY, 1987, 164 (02) :576-577
[5]  
SAINTOLIVE C, 2004, P SOC PHOTO-OPT INS, V5370, P1991
[6]  
Tuy HK., 1993, EUR RADIOL, V3, P129, DOI DOI 10.1007/BF00169785
[7]   Iterative deblurring for CT metal artifact reduction [J].
Wang, G ;
Snyder, DL ;
OSullivan, JA ;
Vannier, MW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (05) :657-664
[8]   A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images [J].
Watzke, O ;
Kalender, WA .
EUROPEAN RADIOLOGY, 2004, 14 (05) :849-856
[9]   X-ray CT high-density artefact suppression in the presence of bones [J].
Wei, JK ;
Chen, LG ;
Sandison, GA ;
Liang, Y ;
Xu, LX .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (24) :5407-5418
[10]   X-ray CT metal artifact reduction using wavelets: Arm application for imaging total hip prostheses [J].
Zhao, SY ;
Roberston, DD ;
Wang, G ;
Whiting, B ;
Bae, KT .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (12) :1238-1247