Determination of the volatiles from tobacco by capillary gas chromatography with atomic emission detection and mass spectrometry

被引:15
作者
Li, Gang [1 ,2 ]
Wu, Da [2 ]
Wang, Ye [2 ]
Xie, Wenyan [2 ]
Zhang, Xiangmin [1 ]
Liu, Baizhan [2 ]
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
[2] Shanghai Tobacco Grp Co Ltd, Ctr Technol, Shanghai, Peoples R China
关键词
Deans switching; Elemental response factors; GC-AED; SOLID-PHASE MICROEXTRACTION; GC-MS; PRECONCENTRATION; DISTILLATION; EXTRACTION;
D O I
10.1002/jssc.201100732
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new gas chromatograph-atomic emission detector (GC-AED) coupled with Deans switching technique for analyzing volatiles from tobaccos were developed. The detector operating parameters (reagent gas pressure and make-up gas flow rate) were optimized. The detection limits for the elements carbon (193 nm), hydrogen (486 nm) and oxygen (171 nm) ranged 0.05-0.2, 0.05-0.3 and 1-11 ng, respectively, depending on the compound. The sensitivity and linearity for the elements carbon (193 nm), hydrogen (486 nm) and oxygen (171 nm) decreased in the order O > H > C. Calibration curves were obtained by plotting peak area versus concentration, and the correlation coefficients relating to linearity were at least 0.9359. Elemental response factors measured on these channels, relative to the carbon 193-nm channel, were hydrogen, 0.38-0.48 (mean % RSD = 5.64), and oxygen, 0.085-0.128 (mean % RSD = 14.9). The evaluation was also done for the new technique and for an established GC-MS technique for the same real samples. The results of GC-AED and GC-MS showed that there was a relatively good agreement between the two sets of data.
引用
收藏
页码:334 / 340
页数:7
相关论文
共 36 条
  • [1] Analysis of oxygen-containing polycyclic aromatic compounds by gas chromatography with atomic emission detection
    Bartle, K. D.
    Hall, S. R.
    Holden, K.
    Mitchell, S. C.
    Ross, A. B.
    [J]. FUEL, 2009, 88 (02) : 348 - 353
  • [2] Analysis of free and bound volatiles by gas chromatography and gas chromatography-mass spectrometry in uncased and cased tobaccos
    Cai, JB
    Liu, BZ
    Ling, P
    Su, QD
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 947 (02) : 267 - 275
  • [3] Solid-phase microextraction for the determination of haloanisoles in wines and other alcoholic beverages using gas chromatography and atomic emission detection
    Campillo, Natalia
    Penalver, Rosa
    Hernandez-Cordoba, Manuel
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1210 (02) : 222 - 228
  • [4] CAREEN M, 2006, J CHROMATOGR A, V1116, P10
  • [5] Carin V. M., 2006, J SEP SCI, V29, P1909
  • [6] Development and validation of a method based on a QuEChERS procedure and heart-cutting GC-MS for determination of five mycotoxins in cereal products
    Cunha, Sara C.
    Fernandes, Jose O.
    [J]. JOURNAL OF SEPARATION SCIENCE, 2010, 33 (4-5) : 600 - 609
  • [7] Solid phase extractive preconcentration coupled to gas chromatography-atomic emission detection for the determination of chlorophenols in water samples
    Elci, Latif
    Kolbe, Nina
    Elci, Sukru G.
    Anderson, Jan T.
    [J]. TALANTA, 2011, 85 (01) : 551 - 555
  • [8] Elizabeth S, 2008, FOOD CHEM TOXICOL, V46, P1582
  • [9] Rapid extraction of volatile compounds using a new simultaneous microwave distillation: Solvent extraction device
    Ferhat, M. A.
    Tigrine-Kordjani, N.
    Chemat, S.
    Meklati, B. Y.
    Chemat, F.
    [J]. CHROMATOGRAPHIA, 2007, 65 (3-4) : 217 - 222
  • [10] FRANCOIS M, 2010, J CHROMATOGR A, V1217, P7528