Investigation of the performance decay of anodic PtRu catalyst with working time of direct methanol fuel cells

被引:35
|
作者
Wang, Zhen-Bo [1 ]
Wang, Xin-Peng [2 ]
Zuo, Peng-Jian [1 ]
Yang, Bo-Qian [2 ]
Yin, Ge-Ping [1 ]
Feng, Xian-Ping [2 ]
机构
[1] Harbin Inst Technol, Dept Appl Chem, Harbin 150001, Peoples R China
[2] Univ Puerto Rico, Dept Phys, San Juan, PR 00931 USA
基金
中国国家自然科学基金;
关键词
direct methanol fuel cell; life test; anodic catalyst degradation; electrochemically active surface area; in situ cyclic voltammetry;
D O I
10.1016/j.jpowsour.2008.03.042
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Life tests of direct methanol fuel cells (DMFC) were carried out with three individual single cells at a current density of 100 mA cm(-2) for three different times under ambient pressure and at a cell temperature of 60 degrees C. X-ray diffraction (XRD) and X-ray photoelectron spectra (XPS) were used to characterize the anodic PtRu catalysts before and after the life tests. XRD results showed that the particle sizes of anodic catalysts increased from an original value of 2.8 to 3.0, 3.2, and 3.3 nm, whereas their lattice parameters first increased and then decreased from an original value of 3.8761 to 3.8879, 3.8777, and 3.8739 A before and after 117, 210, and 312 working hours, respectively. XPS results indicated that during cells' working the contents of Pt and Ru oxides in anodic catalysts increased, but the metal content gradually decreased with test times. Polarization curves, power density curves, and in situ CO-stripping cyclic voltammetric (CV) curves were also plotted to evaluate the performances of fuel cells and electrochemically active surface areas (SEAS) of anodic catalysts before and after life tests. After different time tests, the performances of DMFC lowered to different extents and could not recover their initial performances. The SEAS of anodic catalyst decreased slightly by 4.78 and 9.03 m(2) g(-1) after 117 and 312 working hours, respectively. The utilization of anodic catalysts lowered slightly. This indicates that the change of (SEAS) and utilization of anodic catalysts are not the main factors affecting the performance degradation of DMFC. The dissolution of Ru metal from anodic catalysts surface could be one of the main factors for the performance degradation of the PtRu black catalyst. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 50 条
  • [21] Technical electrodes catalyzed with PtRu on mesoporous ordered carbons for liquid direct methanol fuel cells
    Garbiñe Álvarez
    Francisco Alcaide
    Oscar Miguel
    Laura Calvillo
    María Jesús Lázaro
    Jacob J. Quintana
    Juan Carlos Calderón
    Elena Pastor
    Journal of Solid State Electrochemistry, 2010, 14 : 1027 - 1034
  • [22] Tailoring cathode structure of catalyst coated membranes for performance enhancement in direct methanol fuel cells
    Mehmood, Asad
    An, Myunggi
    Ha, Heung Yong
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (46) : 21366 - 21374
  • [23] Optimization of cathode catalyst layer for direct methanol fuel cells Part I. Experimental investigation
    Liu, Fuqiang
    Wang, Chao-Yang
    ELECTROCHIMICA ACTA, 2006, 52 (03) : 1417 - 1425
  • [24] Improved performance of direct methanol fuel cells with the porous catalyst layer using highly-active nanofiber catalyst
    Tsukagoshi, Yosuke
    Ishitobi, Hirokazu
    Nakagawa, Nobuyoshi
    CARBON RESOURCES CONVERSION, 2018, 1 (01): : 61 - 72
  • [25] Cathode catalyst layer with nanofiber microstructure for direct methanol fuel cells
    Liu, Guicheng
    Ye, Feng
    Xiong, Lingyun
    Lee, Jeongwoo
    Wang, Lei
    Li, Xinyang
    Li, Jingwei
    Lee, Joong Kee
    Yang, Woochul
    ENERGY CONVERSION AND MANAGEMENT, 2020, 218
  • [26] Effects of ethanol in methanol fuel on the performance of membrane electrode assemblies for direct methanol fuel cells
    Yang, Sae-Rom
    Kim, Sang-Kyung
    Jung, Doo-Hwan
    Kim, Taejin
    Kim, Han-Sung
    Peck, Dong-Hyun
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2018, 66 : 100 - 106
  • [27] Modification of Carbon Black with Hydrogen Peroxide for High Performance Anode Catalyst of Direct Methanol Fuel Cells
    Chen, Yu-Wen
    Chen, Han-Gen
    Lo, Man-Yin
    Chen, Yan-Chih
    MATERIALS, 2021, 14 (14)
  • [28] Improvement in direct methanol fuel cell performance by treating the anode at high anodic potential
    Joghee, Prabhuram
    Pylypenko, Svitlana
    Wood, Kevin
    Corpuz, April
    Bender, Guido
    Dinh, Huyen N.
    O'Hayre, Ryan
    JOURNAL OF POWER SOURCES, 2014, 245 : 37 - 47
  • [29] Direct methanol fuel cells
    Dubois, JC
    ACTUALITE CHIMIQUE, 2001, (12): : 58 - 62
  • [30] Factors influencing the performance of catalysts in direct methanol fuel cells
    Chen Weimin
    Sun Gongquan
    Mao Qing
    Yang Shaohua
    Sun Pichang
    Xin Qin
    CHINESE JOURNAL OF CATALYSIS, 2007, 28 (08) : 703 - 708