摘要
The quality of the power is impaired by several reasons. This degradation of the quality of the power is seen e.g. as supply interruptions, transient overvoltages, voltage dips, flicker, harmonics and voltage unbalance. The quality of the power may be improved by using power conditioning equipment, which may be either passive or active. This paper discusses one of the most modem power conditioning devices, i.e. the unified power quality conditioner (UPQC), which consists of the parallel active power filter (PAPF) and the series active power filter (SAPF). The UPQC is a power conditioning device able to compensate all kinds of power quality faults. In this paper the UPQC is used to filter both current and voltage harmonics and to compensate the voltage dip. The paper deals with a way to improve the voltage compensation performance of the SAPF at fundamental frequency in steady-state operation. This improvement is achieved by improving the conventional SAPF control system. The control system of the SAPF is improved by using closed-loop control instead of open-loop control. Finally, the results of the experimental tests verifying the functioning of the proposed control system are presented.
引用
收藏
页码:1193 / 1201
页数:9
相关论文
共 50 条
  • [21] Fuzzy Logic Control of Shunt Active Power Filter for Power Quality Improvement
    Anjana, S.
    Maya, P.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SOFT COMPUTING SYSTEMS, ICSCS 2015, VOL 1, 2016, 397 : 975 - 985
  • [22] Control and Performance of Shunt Current Source Active Power Filter with Series Capacitor
    Parkatti, Perttu
    Salo, Mika
    Tuusa, Heikki
    EPE JOURNAL, 2010, 20 (02) : 49 - 56
  • [23] A comparative study of voltage controllers for series active power filter
    Mekri, Fatiha
    Machmoum, Mohamed
    Ait-Ahmed, Nadia
    Mazari, Benyouness
    ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (06) : 615 - 626
  • [24] Reduction of Harmonics and Voltage Sag Compensation bySeries Active Power Filter
    Nayak, Biraja Prasad
    Shaw, Animesh
    2017 1ST IEEE INTERNATIONAL CONFERENCE ON DATA MANAGEMENT, ANALYTICS AND INNOVATION (ICDMAI), 2017, : 52 - 57
  • [25] A Control Strategy in Active Power Filter for Power Quality Improvement
    Nohra, A. F. Hanna
    Kanaan, H. Y.
    Fadel, M.
    2014 INTERNATIONAL CONFERENCE ON POWER ENGINEERING AND RENEWABLE ENERGY (ICPERE), 2014, : 42 - 47
  • [26] Digital control of an integrated series active filter and diode rectifier with voltage regulation
    le Roux, AD
    Mouton, HD
    Akagi, H
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (06) : 1814 - 1820
  • [27] AC side parallel-series active filter with DC voltage control capability of a diode rectifier
    Reinhold, Andreas
    Raedel, Uwe
    Grohmann, Rolf
    Petzoldt, Juergen
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
  • [28] Power quality improvement using FACTS power filter compensation scheme
    Abdelsalam, Abdelazeem A.
    Desouki, Mohammed E.
    Sharaf, Adel M.
    JOURNAL OF ELECTRICAL SYSTEMS, 2013, 9 (01) : 73 - 83
  • [29] A Novel Grid-Connected Inverter Filtering Method using Series Active Power Filter based on Magnetic Flux Compensation
    Wang, Tingkang
    Li, Dayi
    Gong, Jie
    Hou, Yuning
    2020 23RD INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2020, : 863 - 866
  • [30] An Optimal Compensation Method of Shunt Active Power Filters for System-Wide Voltage Quality Improvement
    Zhai, Hao
    Zhuo, Fang
    Zhu, Chengzhi
    Yi, Hao
    Wang, Zhenxiong
    Tao, Ran
    Wei, Tongjia
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (02) : 1270 - 1281