Characterization of photoacoustic tomography system with dual illumination

被引:8
|
作者
Fukutani, Kazuhiko [1 ]
Someda, Yasuhiro [1 ]
Taku, Masakazu [1 ]
Asao, Yasufumi [1 ]
Kobayashi, Shuichi [1 ]
Yagi, Takayuki [1 ]
Yamakawa, Makoto [2 ]
Shiina, Tsuyoshi [3 ]
Sugie, Tomoharu [3 ]
Toi, Masakazu [3 ]
机构
[1] Canon Inc, Med Imaging Project, Ohta Ku, 3-30-2 Shimomaruko, Tokyo 1468501, Japan
[2] Kyoto Univ, Adv Biomed Engn Res Unit, Kyoto, Japan
[3] Kyoto Univ, Grad Sch Med, Sakyo Ku, Kyoto 6068507, Japan
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2011 | 2011年 / 7899卷
关键词
photoacoustic tomography; deep tissue imaging; dual illumination;
D O I
10.1117/12.873690
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this study, we characterized a newly developed imaging system, "dual illumination mode photoacoustic tomography (PAT) system". The PAT system can simultaneously or separately illuminate biological tissues from a forward and backward direction toward an array transducer. The shape of the custom-made transducer is rectangular, which allows direct illumination of tissue surfaces in front of the array transducer through a holding plate from the backward direction. The transducer frequency was designed at 1 MHz by considering the trade-off relationship between ultrasound attenuation and image resolution. A Ti:Sa laser optically pumped with a Q-switched Nd:YAG laser, having a tunable wavelength of 700 to 900 nm, was chosen for deep light penetration in tissues. The laser light was sufficiently expanded and homogenized to keep the level of laser-pulse fluence on the sample surface under the ANSI safety limit. System performance was tested with phantoms. The results of our study showed that the system visualized all the absorbers embedded in a 50-mm-thick tissue-mimicking phantom with a lateral resolution of 2 similar to 3 mm.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Photoacoustic micro-tomography: system characterization and first results on biological specimens
    Paltauf, Guenther
    Nuster, Robert
    Holotta, Markus
    Grossauer, Harald
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010, 2010, 7564
  • [22] S-Sequence Patterned Illumination for Fixed-Point Iterative Multiple Illumination Photoacoustic Tomography
    Harrison, Tyler
    Shao, Peng
    Zemp, Roger
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2014, 2014, 8943
  • [23] Acoustic-Resolution Photoacoustic Microscopy with Dual-Sided Illumination
    Zeng Silue
    Liu Liangjian
    Chen Tao
    Fang Chihua
    Liu Chengbo
    Zheng Hairong
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2022, 49 (15):
  • [24] Characterization of integrating ultrasound detectors for photoacoustic tomography
    Paltauf, G.
    Nuster, R.
    Burgholzer, P.
    Journal of Applied Physics, 2009, 105 (10):
  • [25] Characterization of integrating ultrasound detectors for photoacoustic tomography
    Paltauf, G.
    Nuster, R.
    Burgholzer, P.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (10)
  • [26] SUPERRESOLUTION PHOTOACOUSTIC TOMOGRAPHY USING RANDOM SPECKLE ILLUMINATION AND SECOND ORDER MOMENTS
    Malik, Osman Asif
    Narumanchi, Venkatalakshmi Vyjayanthi
    Becker, Stephen
    Murray, Todd W.
    2021 IEEE WORKSHOP ON APPLICATIONS OF SIGNAL PROCESSING TO AUDIO AND ACOUSTICS (WASPAA), 2021, : 141 - 145
  • [27] Automated full-breast photoacoustic tomography with non-uniform illumination
    Kelly, Corey J.
    Salcudean, Septimiu E.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494
  • [28] Adaptive dual-speed ultrasound and photoacoustic computed tomography
    Zhang, Yachao
    Wang, Lidai
    PHOTOACOUSTICS, 2022, 27
  • [29] A photoacoustic tomography system for imaging of biological tissues
    Su, YX
    Zhang, F
    Xu, KX
    Yao, JQ
    Wang, RKK
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (15) : 2640 - 2644
  • [30] A Novel System Calibration Method in Photoacoustic Tomography
    Oeri, M.
    Bost, W.
    Fournelle, M.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S540 - S540