Evaluating the growth of pulmonary nodular ground-glass opacity on CT: Comparison of volume rendering and thin slice images

被引:2
|
作者
Liang, Mingzhu [1 ]
Liu, Xueguo [1 ]
Li, Weidong [2 ]
Li, Kunwei [1 ]
Chen, Xiangmeng [1 ]
Wang, Guojie [1 ]
Chen, Kai [1 ]
Zhang, Jinxin [2 ]
机构
[1] Sun Yat Sen Univ, Dept Radiol, Affiliated Hosp 5, Zhuhai 519000, Peoples R China
[2] Sun Yat Sen Univ, Sch Publ Hlth, Guangzhou 510000, Guangdong, Peoples R China
关键词
computed tomography; ground-glass opacity; pulmonary nodule; growth; volume rendering; MAXIMUM INTENSITY PROJECTION; CANCER SCREENING EXPERIENCE; LUNG-CANCER; FOLLOW-UP; COMPUTED-TOMOGRAPHY; SECTION CT; SIZE;
D O I
10.1007/s11596-011-0689-4
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This study examined the value of volume rendering (VR) interpretation in assessing the growth of pulmonary nodular ground-glass opacity (nGGO). A total of 47 nGGOs (average size, 9.5 mm; range, 5.7-20.6 mm) were observed by CT scanning at different time under identical parameter settings. The growth of nGGO was analyzed by three radiologists by comparing the thin slice (TS) CT images of initial and repeat scans with side-by-side cine mode. One week later synchronized VR images of the two scans were compared by side-by-side cine mode to evaluate the nGGO growth. The nodule growth was rated on a 5-degree scale: notable growth, slight growth, dubious growth, stagnant growth, shrinkage. Growth standard was defined as: Density increase a parts per thousand yen 30 HU and (or) diameter increase (by 20% in nodules a parts per thousand yen10 mm, 30% in nodules of 5-9 mm). Receiver operating characteristic (ROC) was performed. The results showed that 32 nGGOs met the growth criteria (29 nGGOs showed an increase in density; 1 nGGO showed an increase in diameter; 2 nGGOs showed an increase in both diameter and density). Area under ROC curve revealed that the performance with VR interpretation was better than that with TS interpretation (P < 0.01, P < 0.05 and P < 0.05 for observers A, B and C respectively). Consistency between different observers was excellent with both VR interpretation (kappa=0.89 for observers A&C, A&B, B&C) and TS interpretation (kappa=0.71 for A&B, kappa=0.68 for A&C, kappa= 0.74 for B&C), but time spending was less with VR interpretation than with TS interpretation (P < 0.0001, P < 0.0001 and P < 0.05 for observers A, B and C, respectively). It was concluded that VR is a useful technique for evaluating the growth of nGGO.
引用
收藏
页码:846 / 851
页数:6
相关论文
共 50 条
  • [1] Evaluating the Growth of Pulmonary Nodular Ground-glass Opacity on CT: Comparison of Volume Rendering and Thin Slice Images
    梁明柱
    柳学国
    李伟栋
    李坤炜
    陈相猛
    王国杰
    陈凯
    张晋昕
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2011, 31 (06) : 846 - 851
  • [2] Evaluating the growth of pulmonary nodular ground-glass opacity on CT: Comparison of volume rendering and thin slice images
    Mingzhu Liang
    Xueguo Liu
    Weidong Li
    Kunwei Li
    Xiangmeng Chen
    Guojie Wang
    Kai Chen
    Jinxin Zhang
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2011, 31 : 846 - 851
  • [3] Clinical, pathological and thin-section CT features of persistent multiple ground-glass opacity nodules: Comparison with solitary ground-glass opacity nodule
    Kim, Tae Jung
    Goo, Jin Mo
    Lee, Kyung Won
    Park, Chang Min
    Lee, Hyun Ju
    LUNG CANCER, 2009, 64 (02) : 171 - 178
  • [4] Ground-glass opacity detection by using correlation between successive slice images
    Kim, Hyoungseop
    Maekado, Masaki
    Tan, Joo Kooi
    Ishikawa, Seiji
    Tsukuda, Masaaki
    INTERNATIONAL JOURNAL ON ARTIFICIAL INTELLIGENCE TOOLS, 2007, 16 (04) : 583 - 592
  • [5] The association between baseline clinical-radiological characteristics and growth of pulmonary nodules with ground-glass opacity
    Kobayashi, Yoshihisa
    Sakao, Yukinori
    Deshpande, Gautam A.
    Fukui, Takayuki
    Mizuno, Tetsuya
    Kuroda, Hiroaki
    Sakakura, Noriaki
    Usami, Noriyasu
    Yatabe, Yasushi
    Mitsudomi, Tetsuya
    LUNG CANCER, 2014, 83 (01) : 61 - 66
  • [6] Measurement of Focal Ground-glass Opacity Diameters on CT Images: Interobserver Agreement in Regard to Identifying Increases in the Size of Ground-Glass Opacities
    Kakinuma, Ryutaro
    Ashizawa, Kazuto
    Kuriyama, Keiko
    Fukushima, Aya
    Ishikawa, Hiroyuki
    Kamiya, Hisashi
    Koizumi, Naoya
    Maruyama, Yuichiro
    Minami, Kazunori
    Nitta, Norihisa
    Oda, Seitaro
    Oshiro, Yasuji
    Kusumoto, Masahiko
    Murayama, Sadayuki
    Murata, Kiyoshi
    Muramatsu, Yukio
    Moriyama, Noriyuki
    ACADEMIC RADIOLOGY, 2012, 19 (04) : 389 - 394
  • [7] Pulmonary malignant focal ground-glass opacity nodules and solid nodules of 3 cm or less: Comparison of multi-detector CT features
    Fan, Li
    Liu, Shi-Yuan
    Li, Qing-Chu
    Yu, Hong
    Xiao, Xiang-Sheng
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2011, 55 (03) : 279 - 285
  • [8] Correlation exploration among CT imaging, pathology and genotype of pulmonary ground-glass opacity
    Cai, Yong
    Chen, Tong
    Zhang, Shiju
    Tan, Min
    Wang, Jiying
    JOURNAL OF CELLULAR AND MOLECULAR MEDICINE, 2023, 27 (14) : 2021 - 2031
  • [9] Focal interstitial fibrosis manifesting as nodular ground-glass opacity: thin-section CT findings
    Chang Min Park
    Jin Mo Goo
    Hyun Ju Lee
    Chang Hyun Lee
    Doo Hyun Chung
    Eun Ju Chun
    Jung-Gi Im
    European Radiology, 2007, 17 : 2325 - 2331
  • [10] Focal interstitial fibrosis manifesting as nodular ground-glass opacity: thin-section CT findings
    Park, Chang Min
    Goo, Jin Mo
    Lee, Hyun Ju
    Lee, Chang Hyun
    Chung, Doo Hyun
    Chun, Eun Ju
    Im, Jung-Gi
    EUROPEAN RADIOLOGY, 2007, 17 (09) : 2325 - 2331