Image quality and dose differences caused by vendor-specific image processing of neonatal radiographs

被引:8
|
作者
Sensakovic, William F. [1 ]
O'Dell, M. Cody [1 ]
Letter, Haley [1 ]
Kohler, Nathan [1 ]
Rop, Baiywo [1 ]
Cook, Jane [1 ]
Logsdon, Gregory [1 ]
Varich, Laura [1 ]
机构
[1] Florida Hosp, Imaging Adm, 601 E Rollins St, Orlando, FL 32803 USA
关键词
Chest; Image processing; Image quality; Neonate; Radiation dose; Radiography; IONIZING-RADIATION; CHEST; EXPOSURE; POPULATION; REDUCTION; INFANTS; DISEASE; BACK; UNIT;
D O I
10.1007/s00247-016-3663-2
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Image processing plays an important role in optimizing image quality and radiation dose in projection radiography. Unfortunately commercial algorithms are black boxes that are often left at or near vendor default settings rather than being optimized. We hypothesize that different commercial image-processing systems, when left at or near default settings, create significant differences in image quality. We further hypothesize that image-quality differences can be exploited to produce images of equivalent quality but lower radiation dose. We used a portable radiography system to acquire images on a neonatal chest phantom and recorded the entrance surface air kerma (ESAK). We applied two image-processing systems (Optima XR220amx, by GE Healthcare, Waukesha, WI; and MUSICA(2) by Agfa HealthCare, Mortsel, Belgium) to the images. Seven observers (attending pediatric radiologists and radiology residents) independently assessed image quality using two methods: rating and matching. Image-quality ratings were independently assessed by each observer on a 10-point scale. Matching consisted of each observer matching GE-processed images and Agfa-processed images with equivalent image quality. A total of 210 rating tasks and 42 matching tasks were performed and effective dose was estimated. Median Agfa-processed image-quality ratings were higher than GE-processed ratings. Non-diagnostic ratings were seen over a wider range of doses for GE-processed images than for Agfa-processed images. During matching tasks, observers matched image quality between GE-processed images and Agfa-processed images acquired at a lower effective dose (11 +/- 9 mu Sv; P < 0.0001). Image-processing methods significantly impact perceived image quality. These image-quality differences can be exploited to alter protocols and produce images of equivalent image quality but lower doses. Those purchasing projection radiography systems or third-party image-processing software should be aware that image processing can significantly impact image quality when settings are left near default values.
引用
收藏
页码:1606 / 1613
页数:8
相关论文
共 50 条
  • [1] Image quality and dose differences caused by vendor-specific image processing of neonatal radiographs
    William F. Sensakovic
    M. Cody O’Dell
    Haley Letter
    Nathan Kohler
    Baiywo Rop
    Jane Cook
    Gregory Logsdon
    Laura Varich
    Pediatric Radiology, 2016, 46 : 1606 - 1613
  • [2] Image quality of ultralow-dose chest CT using deep learning techniques: potential superiority of vendor-agnostic post-processing over vendor-specific techniques
    Nam, Ju Gang
    Ahn, Chulkyun
    Choi, Hyewon
    Hong, Wonju
    Park, Jongsoo
    Kim, Jong Hyo
    Goo, Jin Mo
    EUROPEAN RADIOLOGY, 2021, 31 (07) : 5139 - 5147
  • [3] Radiation Dose and Image Quality in Adult Computed Tomography Scans
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Theeb, Mostafa Abdelrahman
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (02) : 223 - 231
  • [4] Localiser radiographs in CT: Current practice, radiation dose, image quality and clinical applications
    Al-Hayek, Y.
    Ofori-Manteaw, B.
    Frame, N.
    Spuur, K.
    Zheng, X.
    Rose, L.
    Chau, M.
    RADIOGRAPHY, 2024, 30 (06) : 1546 - 1555
  • [5] Optimization of image quality and patient dose in radiographs of paediatric extremities using direct digital radiography
    Jones, A.
    Ansell, C.
    Jerrom, C.
    Honey, I. D.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1050)
  • [6] Image quality and radiation dose reduction in chest CT in pulmonary infection
    Cristofaro, Massimo
    Rizzi, Elisa Busi
    Piselli, Pierluca
    Pianura, Elisa
    Petrone, Ada
    Fusco, Nicoletta
    Di Stefano, Federica
    Schinina', Vincenzo
    RADIOLOGIA MEDICA, 2020, 125 (05): : 451 - 460
  • [7] Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques
    Tricarico, Francesco
    Hlavacek, Anthony M.
    Schoepf, U. Joseph
    Ebersberger, Ullrich
    Nance, John W., Jr.
    Vliegenthart, Rozemarijn
    Cho, Young Jun
    Spears, J. Reid
    Secchi, Francesco
    Savino, Giancarlo
    Marano, Riccardo
    Schoenberg, Stefan O.
    Bonomo, Lorenzo
    Apfaltrer, Paul
    EUROPEAN RADIOLOGY, 2013, 23 (05) : 1306 - 1315
  • [8] Value of bone suppression software in chest radiographs for improving image quality and reducing radiation dose
    Hong, Gil-Sun
    Do, Kyung-Hyun
    Son, A-Yeon
    Jo, Kyung-Wook
    Kim, Kwang Pyo
    Yun, Jihye
    Lee, Choong Wook
    EUROPEAN RADIOLOGY, 2021, 31 (07) : 5160 - 5171
  • [9] Image Quality Improvement of Low-dose Abdominal CT using Deep Learning Image Reconstruction Compared with the Second Generation Iterative Reconstruction
    Kang, Hyo-Jin
    Lee, Jeong Min
    Park, Sae Jin
    Lee, Sang Min
    Joo, Ijin
    Yoon, Jeong Hee
    CURRENT MEDICAL IMAGING, 2024, 20
  • [10] Neonatal chest computed radiography: Image processing and optimal image display
    Don, Steven
    Whiting, Bruce R.
    Ellinwood, Jacquelyn S.
    Foos, David H.
    Kronemer, Keith A.
    Kraus, Richard A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (04) : 1138 - 1144