Comparative behavior of glucose oxidase and oxalate oxidase immobilized in mucin/chitosan hydrogels for biosensors applications

被引:12
作者
Benavidez, Tomas E. [1 ]
Baruzzi, Ana M. [1 ]
机构
[1] Univ Nacl Cordoba, INFIQC CONICET, Dept Fis Quim, Fac Ciencias Quim, RA-5016 Cordoba, Argentina
关键词
Biosensor; Enzymes; Hydrogel; CHITOSAN MEMBRANES; SOLUTE DIFFUSION; DRUG-DELIVERY; CROSS-LINKING; RELEASE; ENZYME; BIOMATERIALS; MECHANISMS; TRANSPORT; NETWORKS;
D O I
10.1016/j.polymer.2011.12.014
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The analytical response of amperometric glucose electrodes was explained in the framework of the properties of hydrogels with different muc/chit ratio at pH = 7.00 used as immobilization matrix for glucose oxidase. The continuous increase in the sensitivity of the electrodes with the amount of chitosan was attributed to a more efficient crosslinking without affecting the enzyme activity. The results were compared with those obtained using the same matrices to immobilize Oxalate Oxidase at pH = 2.85 where it has the highest activity. A maximum sensitivity at muc/chit 70/30 ratio for these oxalate electrodes was observed. Decrease in permeability of negatively charged oxalate with the chitosan content in the matrices, in spite of the high partition coefficient, explains the analytical differences with glucose electrodes. Swelling and viscoelasticity of the hydrogels allowed to asses the importance of a hydrophilic environment for the enzyme in both cases. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:438 / 444
页数:7
相关论文
共 33 条
[1]   Biomolecular immobilization on conducting polymers for biosensing applications [J].
Ahuja, Tarushee ;
Mir, Irfan Ahmad ;
Kumar, Devendra ;
Rajesh .
BIOMATERIALS, 2007, 28 (05) :791-805
[2]   FACTORS INFLUENCING DRUG AND PROTEIN-TRANSPORT AND RELEASE FROM IONIC HYDROGELS [J].
AMENDE, MT ;
HARIHARAN, D ;
PEPPAS, NA .
REACTIVE POLYMERS, 1995, 25 (2-3) :127-137
[3]   Solute diffusion within hydrogels. Mechanisms and models [J].
Amsden, B .
MACROMOLECULES, 1998, 31 (23) :8382-8395
[4]   Physicochemical properties of a mucin/chitosan matrix used for the development of an oxalate biosensor [J].
Benavidez, Tomas E. ;
Alvarez, Cecilia I. ;
Baruzzi, Ana M. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 143 (02) :660-665
[5]   Amperometric Biosensor Based on Immobilization of Oxalate Oxidase in a Mucin/Chitosan Matrix [J].
Benavidez, Tomas E. ;
Capra, Raul H. ;
Alvarez, Cecilia I. ;
Baruzzi, Ana M. .
ELECTROANALYSIS, 2009, 21 (07) :837-843
[6]   Bio-smart hydrogels: co-joined molecular recognition and signal transduction in biosensor fabrication and drug delivery [J].
Brahim, S ;
Narinesingh, D ;
Guiseppi-Elie, A .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :973-981
[7]  
Brinda D, 1991, ANAL CHEM, V63, P1692
[8]   Rheological, dielectric and diffusion analysis of mucin/carbopol matrices used in amperometric biosensors [J].
Capra, Raul H. ;
Aruzzi, Ana M. B. ;
Quinzani, Lidia M. ;
Strumia, Miriam C. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 124 (02) :466-476
[9]   Mucin/carbopol matrix to immobilize oxalate oxidase in a urine oxalate amperometric biosensor [J].
Capra, RH ;
Strumia, M ;
Vadgama, PM ;
Baruzzi, AM .
ANALYTICA CHIMICA ACTA, 2005, 530 (01) :49-54
[10]   ENTRAPMENT OF BIOMOLECULES INTO HYDROGELS OBTAINED BY RADIATION-INDUCED POLYMERIZATION [J].
CARENZA, M ;
VERONESE, FM .
JOURNAL OF CONTROLLED RELEASE, 1994, 29 (1-2) :187-193