Large enhancement of sensitivity and a wider working range of glass pH electrode with amperometric and potentiometric responses

被引:10
作者
Cheng, Changming [1 ]
Tian, Xianqing [2 ]
Guo, Yong [2 ]
Li, Yi [1 ]
Yuan, Hongyan [1 ]
Xiao, Dan [1 ,2 ]
机构
[1] Sichuan Univ, Coll Chem Engn, Chengdu 610065, Peoples R China
[2] Sichuan Univ, Coll Chem, Key Lab Green Chem & Technol, Minist Educ, Chengdu 610065, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemistry; Sensor; Glass pH electrode; Non-equilibrium; Sensitivity; ION-SELECTIVE MEMBRANES; GALVANOSTATIC POLARIZATION; DETECTION LIMITS; ELECTROCHEMICAL SENSORS; PULSE VOLTAMMETRY; TRACE LEVELS; PULSTRODES; MECHANISM; MODEL;
D O I
10.1016/j.electacta.2011.08.065
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this communication, a new four-electrode measurement system has been developed to improve the analytical performance of a glass pH electrode. The sensitivity of detection is greatly enhanced and the working range is widened. In this new configuration, the potentiometric response slope of the pH electrode, dE/dpH, could be as high as -669 mV in the pH range 4-10. Amperometric measurement could also be employed to monitor the pH of aqueous solution and the response sensitivity (dI/dpH) is similar to 67 nA. A two-signal (i.e., potential and current) synchronous detection technology has been exploited for pH monitoring. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:9883 / 9886
页数:4
相关论文
共 49 条
[1]   A SIMPLE AND INEXPENSIVE FUNCTION GENERATOR AND A 4-ELECTRODE CELL FOR CYCLIC VOLTAMMETRY [J].
ALBAHADILY, FN ;
MOTTOLA, HA .
JOURNAL OF CHEMICAL EDUCATION, 1986, 63 (03) :271-273
[2]   Electrochemical sensors [J].
Bakker, E ;
Telting-Diaz, M .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2781-2800
[3]   Potentiometry at trace levels [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (01) :11-19
[4]   Modern Potentiometry [J].
Bakker, Eric ;
Pretsch, Ernoe .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (30) :5660-5668
[5]   Electrochemical sensors [J].
Bakker, Eric ;
Qin, Yu .
ANALYTICAL CHEMISTRY, 2006, 78 (12) :3965-3983
[6]   EIS study of potentiometric membranes selective to Ca2+ employing the new ionophoric antibiotic tetronasin [J].
Calvo, D ;
Bartrolí, J ;
del Valle, M .
ELECTROCHIMICA ACTA, 2006, 51 (8-9) :1569-1575
[7]   Potentiometric biosensing of proteins with ultrasensitive ion-selective microelectrodes and nanoparticle labels [J].
Chumbimuni-Torres, Karin Y. ;
Dai, Zong ;
Rubinova, Nastassia ;
Xiang, Yun ;
Pretsch, Erno ;
Wang, Joseph ;
Bakker, Eric .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (42) :13676-13677
[8]  
Cremer M, 1906, Z BIOL-MUNICH, V29, P562
[9]   Polyion-sensitive membrane electrodes for detecting phosphate-rich biological polyanions [J].
Esson, JM ;
Meyerhoff, ME .
ELECTROANALYSIS, 1997, 9 (17) :1325-1330
[10]   Study of the potentiometric response of the doped spinel Li1.05Al0.02Mn1.98O4 for the optimization of a selective lithium ion sensor [J].
Freitas, Bruno H. ;
Amaral, Fabio A. ;
Bocchi, Nerilso ;
Teixeira, Marcos F. S. .
ELECTROCHIMICA ACTA, 2010, 55 (20) :5659-5664