Arthroscopic Rotator Cuff Repair Using a Suture Bridge Technique Is the Repair Integrity Actually Maintained?

被引:167
作者
Cho, Nam Su [1 ]
Lee, Bong Gun [1 ]
Rhee, Yong Girl [1 ]
机构
[1] Kyung Hee Univ, Dept Orthopaed Surg, Coll Med, Shoulder & Elbow Clin, Seoul 130702, South Korea
关键词
shoulder; rotator cuff tear; arthroscopic repair; suture bridge technique; retear; SINGLE-ROW; TRANSOSSEOUS SUTURE; FATTY DEGENERATION; TEARS; FIXATION; FAILURE; ANCHORS; LOAD;
D O I
10.1177/0363546510397171
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Suture bridge repair has been recognized to have superior biomechanical characteristics, as shown in previous biomechanical studies. However, it is not clear whether the tendon heals better in vivo after suture bridge repair. Purpose: To evaluate the clinical results and repair integrity after arthroscopic rotator cuff repair using a suture bridge technique for patients with rotator cuff tears. Study Design: Case series; Level of evidence, 4. Methods: One hundred twenty-three shoulders (120 patients) that underwent arthroscopic suture bridge repair for full-thickness rotator cuff tear were enrolled for this study. The mean duration of follow-up was 25.2 months (range, 16-34 months). The postoperative repair integrity was analyzed with use of magnetic resonance imaging (MRI) in 87 shoulders. According to the retear patterns on postoperative MRI, the cases were divided into type 1 (failure at the original repair site) or 2 (failure around the medial row). Results: At the last follow-up, the University of California at Los Angeles (UCLA) score improved from the preoperative mean of 13.2 points to 29.7 points (P < .001). The rotator cuff was completely healed in 58 (66.7%) of the 87 shoulders, and there was a recurrent tear in 29 shoulders (33.3%). The incidence of retear tended to increase with age older than 60 years at the time of surgery (P = .002). When there was a larger intraoperative tear, the rate of retear was also higher (P = .002). When the severity of preoperative fatty degeneration of the cuff muscles was higher, there was a greater chance of a recurrent tear (P < .001). The retear patterns on postoperative MRI in 29 shoulders with recurrent failures were classified as type 1 in 12 shoulders (41.4%) and type 2 in 17 shoulders (58.6%). The preoperative cuff tear size did not have an influence on retear patterns (P = .236), but the percentage of type 1 retear increased with the severity of fatty degeneration or muscle atrophy (P = .041, .023). Conclusion: Arthroscopic suture bridge repair of full-thickness rotator cuff tears led to a relatively high rate of recurrent defects. However, the mean 25-month follow-up demonstrated excellent pain relief and improvement in the ability to perform the activities of daily living, despite the structural failures. The factors affecting tendon healing were the patient's age, the size and extent of the tear, and the presence of fatty degeneration in the rotator cuff muscle. The retear in cases with a suture bridge technique tended to be more frequently at the musculotendinous junction.
引用
收藏
页码:2108 / 2116
页数:9
相关论文
共 37 条
[1]   Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques [J].
Ahmad, CS ;
Stewart, AM ;
Izquierdo, R ;
Bigliani, LU .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (11) :1667-1671
[2]   Cyclic load testing of biodegradable suture anchors containing 2 high-strength sutures [J].
Barber, F. Alan ;
Coons, David A. ;
Ruiz-Suarez, Michell .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (04) :355-360
[4]   Cuff integrity after arthroscopic versus open rotator cuff repair: A prospective study [J].
Bishop, Julie ;
Klepps, Steven ;
Lo, Ian K. ;
Bird, Justin ;
Gladstone, James N. ;
Flatow, Evan L. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (03) :290-299
[5]   The Factors Affecting the Clinical Outcome and Integrity of Arthroscopically Repaired Rotator Cuff Tears of the Shoulder [J].
Cho, Nam Su ;
Rhee, Yong Girl .
CLINICS IN ORTHOPEDIC SURGERY, 2009, 1 (02) :96-104
[6]   Retear Patterns After Arthroscopic Rotator Cuff Repair Single-Row Versus Suture Bridge Technique [J].
Cho, Nam Su ;
Yi, Jin Woong ;
Lee, Bong Gun ;
Rhee, Yong Girl .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2010, 38 (04) :664-671
[7]   Arthroscopic rotator cuff repairs: An anatomic and biomechanical rationale for different suture-anchor repair configurations [J].
Cole, Brian J. ;
ElAttrache, Neal S. ;
Anbari, Ammar .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (06) :662-669
[8]  
CONSTANT CR, 1987, CLIN ORTHOP RELAT R, P160
[9]   Mode of failure for rotator cuff repair with suture anchors identified at revision surgery [J].
Cummins, CA ;
Murrell, GAC .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (02) :128-133
[10]   Rotator cuff repair: An ex vivo analysis of suture anchor repair techniques on initial load to failure [J].
Cummins, CA ;
Appleyard, RC ;
Strickland, S ;
Haen, PS ;
Chen, SY ;
Murrell, GAC .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (10) :1236-1241