Real-time intrafraction prostate motion during linac based stereotactic radiotherapy with rectal displacement

被引:21
|
作者
Legge, Kimberley [1 ]
Doan Nguyen [2 ]
Ng, Jin Aun [2 ]
Wilton, Lee [3 ]
Richardson, Matthew [3 ]
Booth, Jeremy [4 ]
Keall, Paul [2 ]
O'Connor, Darryl J. [1 ]
Greer, Peter [3 ]
Martin, Jarad [5 ]
机构
[1] Univ Newcastle, Sch Math & Phys Sci, Callaghan, NSW, Australia
[2] Univ Sydney, Radiat Phys Lab, Sydney, NSW, Australia
[3] Calvary Mater Newcastle, Radiat Oncol Dept, Newcastle, NSW, Australia
[4] Royal North Shore Hosp, Northern Sydney Canc Ctr, St Leonards, NSW, Australia
[5] Calvary Mater Newcastle, Hunter Reg Mail Ctr, Newcastle, NSW, Australia
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2017年 / 18卷 / 06期
关键词
intrafraction motion; stereotactic radiation therapy; IMAGE-GUIDED RADIOTHERAPY; RADIATION-THERAPY; BEAM RADIOTHERAPY; BODY RADIOTHERAPY; TRACKING SYSTEM; CANCER; ACCURACY; POSITION; BOOST;
D O I
10.1002/acm2.12195
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Kilovoltage Intrafraction Monitoring (KIM) is a method which determines the three-dimensional position of the prostate from two-dimensional kilovoltage (kV) projections taken during linac based radiotherapy treatment with real-time feedback. Rectal displacement devices (RDDs) allow for improved rectal dosimetry during prostate cancer treatment. This study used KIM to perform a preliminary investigation of prostate intrafraction motion observed in patients with an RDD in place. Methods: Ten patients with intermediate to high-risk prostate cancer were treated with a Rectafix RDD in place during two boost fractions of 9.5-10 Gy delivered using volumetric modulated arc therapy (VMAT) on Clinac iX and Truebeam linacs. Two-dimensional kV projections were acquired during treatment. KIM software was used following treatment to determine the displacement of the prostate over time. The displacement results were analyzed to determine the percentage of treatment time the prostate spent within 1 mm, between 1 and 2 mm, between 2 and 3 mm and greater than 3 mm from its initial position. Results: KIM successfully measured displacement for 19 prostate stereotactic boost fractions. The prostate was within 1 mm of its initial position for 84.8%, 1 -2 mm for 14%, 2-3 mm 1.2% and >= 3 mm only 0.4% of the treatment time. Conclusions: In this preliminary study using KIM, KIM was successfully used to measure prostate intrafraction motion, which was found to be small in the presence of a rectal displacement device.
引用
收藏
页码:130 / 136
页数:7
相关论文
共 50 条
  • [41] Prostate displacement during transabdominal ultrasound image-guided radiotherapy assessed by real-time four-dimensional transperineal monitoring
    Baker, Mariwan
    Behrens, Claus F.
    ACTA ONCOLOGICA, 2015, 54 (09) : 1508 - 1514
  • [42] Evaluation of dynamic tumour tracking radiotherapy with real-time monitoring for lung tumours using a gimbal mounted linac
    Matsuo, Yukinori
    Ueki, Nami
    Takayama, Kenji
    Nakamura, Mitsuhiro
    Miyabe, Yuki
    Ishihara, Yoshitomo
    Mukumoto, Nobutaka
    Yano, Shinsuke
    Tanabe, Hiroaki
    Kaneko, Shuji
    Mizowaki, Takashi
    Monzen, Hajime
    Sawada, Akira
    Kokubo, Masaki
    Hiraoka, Masahiro
    RADIOTHERAPY AND ONCOLOGY, 2014, 112 (03) : 360 - 364
  • [43] PRACTICAL METHOD OF ADAPTIVE RADIOTHERAPY FOR PROSTATE CANCER USING REAL-TIME ELECTROMAGNETIC TRACKING
    Olsen, Jeffrey R.
    Noel, Camille E.
    Baker, Kenneth
    Santanam, Lakshmi
    Michalski, Jeff M.
    Parikh, Parag J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1903 - 1911
  • [44] Ghost marker detection and elimination in marker-based optical tracking systems for real-time tracking in stereotactic body radiotherapy
    Yan, Guanghua
    Li, Jonathan
    Huang, Yin
    Mittauer, Kathryn
    Lu, Bo
    Liu, Chihray
    MEDICAL PHYSICS, 2014, 41 (10)
  • [45] Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy
    Shirato, Hiroki
    Shimizu, Shinichi
    Kitamura, Kei
    Onimaru, Rikiya
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2007, 12 (01) : 8 - 16
  • [46] Assessing the Dosimetric Impact of Real-Time Prostate Motion During Volumetric Modulated Arc Therapy
    Diego Azcona, Juan
    Xing, Lei
    Chen, Xin
    Bush, Karl
    Li, Ruijiang
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 88 (05): : 1167 - 1174
  • [47] Hippocampal dose during Linac-based stereotactic radiotherapy for brain metastases: An observational study
    Fiorentino, Alba
    Tebano, Umberto
    Sicignano, Gianluisa
    Ricchetti, Francesco
    Di Paola, Gioacchino
    Aiello, Dario
    Giaj-Levra, Niccolo
    Mazzola, Rosario
    Fersino, Sergio
    Ruggieri, Ruggero
    Alongi, Filippo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 49 : 135 - 138
  • [48] GAINS FROM REAL-TIME TRACKING OF PROSTATE MOTION DURING EXTERNAL BEAM RADIATION THERAPY
    Li, Jin Sheng
    Jin, Lihui
    Pollack, Alan
    Horwitz, Eric M.
    Buyyounouski, Mark K.
    Price, Robert A., Jr.
    Ma, Chang-Ming
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (05): : 1613 - 1620
  • [49] Dosimetric impact of intrafraction motion on boosts on intraprostatic lesions: a simulation based on actual motion data from real time ultrasound tracking
    Ballhausen, Hendrik
    Li, Minglun
    Reiner, Michael
    Belka, Claus
    RADIATION ONCOLOGY, 2019, 14 (1)
  • [50] Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods
    Beltran, Chris.
    Herman, Michael G.
    Davis, Brian J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01): : 289 - 295