Real-time intrafraction prostate motion during linac based stereotactic radiotherapy with rectal displacement

被引:21
|
作者
Legge, Kimberley [1 ]
Doan Nguyen [2 ]
Ng, Jin Aun [2 ]
Wilton, Lee [3 ]
Richardson, Matthew [3 ]
Booth, Jeremy [4 ]
Keall, Paul [2 ]
O'Connor, Darryl J. [1 ]
Greer, Peter [3 ]
Martin, Jarad [5 ]
机构
[1] Univ Newcastle, Sch Math & Phys Sci, Callaghan, NSW, Australia
[2] Univ Sydney, Radiat Phys Lab, Sydney, NSW, Australia
[3] Calvary Mater Newcastle, Radiat Oncol Dept, Newcastle, NSW, Australia
[4] Royal North Shore Hosp, Northern Sydney Canc Ctr, St Leonards, NSW, Australia
[5] Calvary Mater Newcastle, Hunter Reg Mail Ctr, Newcastle, NSW, Australia
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2017年 / 18卷 / 06期
关键词
intrafraction motion; stereotactic radiation therapy; IMAGE-GUIDED RADIOTHERAPY; RADIATION-THERAPY; BEAM RADIOTHERAPY; BODY RADIOTHERAPY; TRACKING SYSTEM; CANCER; ACCURACY; POSITION; BOOST;
D O I
10.1002/acm2.12195
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Kilovoltage Intrafraction Monitoring (KIM) is a method which determines the three-dimensional position of the prostate from two-dimensional kilovoltage (kV) projections taken during linac based radiotherapy treatment with real-time feedback. Rectal displacement devices (RDDs) allow for improved rectal dosimetry during prostate cancer treatment. This study used KIM to perform a preliminary investigation of prostate intrafraction motion observed in patients with an RDD in place. Methods: Ten patients with intermediate to high-risk prostate cancer were treated with a Rectafix RDD in place during two boost fractions of 9.5-10 Gy delivered using volumetric modulated arc therapy (VMAT) on Clinac iX and Truebeam linacs. Two-dimensional kV projections were acquired during treatment. KIM software was used following treatment to determine the displacement of the prostate over time. The displacement results were analyzed to determine the percentage of treatment time the prostate spent within 1 mm, between 1 and 2 mm, between 2 and 3 mm and greater than 3 mm from its initial position. Results: KIM successfully measured displacement for 19 prostate stereotactic boost fractions. The prostate was within 1 mm of its initial position for 84.8%, 1 -2 mm for 14%, 2-3 mm 1.2% and >= 3 mm only 0.4% of the treatment time. Conclusions: In this preliminary study using KIM, KIM was successfully used to measure prostate intrafraction motion, which was found to be small in the presence of a rectal displacement device.
引用
收藏
页码:130 / 136
页数:7
相关论文
共 50 条
  • [31] Clinical application of a sub-fractionation workflow for intrafraction re-planning during prostate radiotherapy treatment on a 1.5 Tesla MR-Linac: A practical method to mitigate intrafraction motion
    Willigenburg, Thomas
    Zachiu, Cornel
    Bol, Gijsbert H.
    de Groot-van Beugel, Eline N.
    Lagendijk, Jan J. W.
    van der Voort van Zyp, Jochem R. N.
    Raaymakers, Bas W.
    de Boer, Johannes C. J.
    RADIOTHERAPY AND ONCOLOGY, 2022, 176 : 25 - 30
  • [32] Impact of hydrogel peri-rectal spacer insertion on seminal vesicles intrafraction motion during 1.5 T-MRI-guided adaptive stereotactic body radiotherapy for localized prostate cancer
    Mazzola, Rosario
    Sicignano, Gianluisa
    Cuccia, Francesco
    Vitale, Claudio
    Rigo, Michele
    Giaj-Levra, Niccolo
    Nicosia, Luca
    Figlia, Vanessa
    Ricchetti, Francesco
    Attina, Giorgio
    Pastorello, Edoardo
    De Simone, Antonio
    Gurrera, Davide
    Naccarato, Stefania
    Ruggieri, Ruggero
    Alongi, Filippo
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1126)
  • [33] Adaptive Imaging Versus Periodic Surveillance for Intrafraction Motion Management During Prostate Cancer Radiotherapy
    Ma, Xiangyu
    Yan, Huagang
    Nath, Ravinder
    Chen, Zhe
    Li, Haiyun
    Liu, Wu
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2019, 18
  • [34] Impact of hydrogel peri-rectal spacer insertion on prostate gland intra-fraction motion during 1.5 T MR-guided stereotactic body radiotherapy
    Cuccia, Francesco
    Mazzola, Rosario
    Nicosia, Luca
    Figlia, Vanessa
    Giaj-Levra, Niccolo
    Ricchetti, Francesco
    Rigo, Michele
    Vitale, Claudio
    Mantoan, Beatrice
    De Simone, Antonio
    Sicignano, Gianluisa
    Ruggieri, Ruggero
    Cavalleri, Stefano
    Alongi, Filippo
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [35] Assessing Feasibility of Real-time Ultrasound Monitoring in Stereotactic Body Radiotherapy of Liver Tumors
    Zhong, Yahua
    Stephans, Kevin
    Qi, Peng
    Yu, Naichang
    Wong, John
    Xia, Ping
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (03) : 243 - 250
  • [36] Assessment of MLC tracking performance during hypofractionated prostate radiotherapy using real-time dose reconstruction
    Fast, M. F.
    Kamerling, C. P.
    Ziegenhein, P.
    Menten, M. J.
    Bedford, J. L.
    Nill, S.
    Oelfke, U.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04) : 1546 - 1562
  • [37] Management of three-dimensional intrafraction motion through real-time DMLC tracking
    Sawant, Amit
    Venkat, Raghu
    Srivastava, Vikram
    Carlson, David
    Povzner, Sergey
    Cattell, Herb
    Keall, Paul
    MEDICAL PHYSICS, 2008, 35 (05) : 2050 - 2061
  • [38] Adaptive hypofractionted and stereotactic body radiotherapy for lung tumors with real-time MRI guidance
    Bryant, John M.
    Sim, Austin J.
    Feygelman, Vladimir
    Latifi, Kujtim
    Rosenberg, Stephen A.
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [39] Minimum non-isotropic and asymmetric margins for taking into account intrafraction prostate motion during moderately hypofractionated radiotherapy
    di Franco, Francesca
    Baudier, Thomas
    Gassa, Frederic
    Munoz, Alexandre
    Martinon, Murielle
    Charcosset, Sarah
    Vigier-Lafosse, Emilie
    Pommier, Pascal
    Sarrut, David
    Biston, Marie-Claude
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 96 : 114 - 120
  • [40] Robotic real-time translational and rotational head motion correction during frameless stereotactic radiosurgery
    Liu, Xinmin
    Belcher, Andrew H.
    Grelewicz, Zachary
    Wiersma, Rodney D.
    MEDICAL PHYSICS, 2015, 42 (06) : 2757 - 2763