Three-Dimensional Phase Contrast Angiography of the Mouse Aortic Arch Using Spiral MRI

被引:35
作者
Janiczek, Robert L. [1 ]
Blackman, Brett R. [1 ]
Roy, R. Jack [2 ]
Meyer, Craig H. [1 ,2 ]
Acton, Scott T. [1 ,3 ]
Epstein, Frederick H. [1 ,2 ]
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA USA
[2] Univ Virginia, Dept Radiol, Charlottesville, VA USA
[3] Univ Virginia, Dept Elect & Comp Engn, Charlottesville, VA USA
关键词
spiral; phase contrast; mouse; wall shear stress; MRI; WALL SHEAR-STRESS; FLOW; ATHEROSCLEROSIS; MICE; QUANTIFICATION; BIFURCATION; MECHANISMS; DISEASE;
D O I
10.1002/mrm.22937
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Atherosclerosis is a complex disease whose spatial distribution is hypothesized to be influenced by the local hemodynamic environment. The use of transgenic mice provides a mechanism to study the relationship between hemodynamic forces, most notably wall shear stress (WSS), and the molecular factors that influence the disease process. Phase contrast MRI using rectilinear trajectories has been used to measure boundary conditions for use in computational fluid dynamic models. However, the unique flow environment of the mouse precludes use of standard imaging techniques in complex, curved flow regions such as the aortic arch. In this article, two-dimensional and three-dimensional spiral cine phase contrast sequences are presented that enable measurement of velocity profiles in curved regions of the mouse vasculature. WSS is calculated directly from the spatial velocity gradient, enabling WSS calculation with a minimal set of assumptions. In contrast to the outer radius of the aortic arch, the inner radius has a lower time-averaged longitudinal WSS (7.06 +/- 0.76 dyne/cm(2) vs. 18.86 +/- 1.27 dyne/cm(2); P < 0.01) and higher oscillatory shear index (0.14 +/- 0.01 vs. 0.08 +/- 0.01; P < 0.01). This finding is in agreement with humans, where WSS is lower and more oscillatory along the inner radius, an atheroprone region, than the outer radius, an atheroprotective region. Magn Reson Med 66: 1382-1390, 2011. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1382 / 1390
页数:9
相关论文
共 35 条
[1]   Flux driven automatic centerline extraction [J].
Bouix, S ;
Siddiqi, K ;
Tannenbaum, A .
MEDICAL IMAGE ANALYSIS, 2005, 9 (03) :209-221
[2]  
Bühler K, 2004, MATH VISUAL, P399
[3]   Shear stress affects the intracellular distribution of eNOS: direct demonstration by a novel in vivo technique [J].
Cheng, C ;
van Haperen, R ;
de Waard, M ;
van Damme, LCA ;
Tempel, D ;
Hanemaaijer, L ;
van Cappellen, GWA ;
Bos, J ;
Slager, CJ ;
Duncker, DJ ;
van der Steen, AFW ;
de Crom, R ;
Krams, R .
BLOOD, 2005, 106 (12) :3691-3698
[4]   Atherosclerotic lesion size and vulnerability are determined by patterns of fluid shear stress [J].
Cheng, Caroline ;
Tempel, Dennie ;
van Haperen, Rien ;
van der Baan, Arjen ;
Grosveld, Frank ;
Daemen, Mat J. A. P. ;
Krams, Rob ;
de Crom, Rini .
CIRCULATION, 2006, 113 (23) :2744-2753
[5]   The role of shear stress in the pathogenesis of atherosclerosis [J].
Cunningham, KS ;
Gotlieb, AI .
LABORATORY INVESTIGATION, 2005, 85 (01) :9-23
[6]   Simple correction method for k-space trajectory deviations in MRI [J].
Duyn, JH ;
Yang, YH ;
Frank, JA ;
van der Veen, JW .
JOURNAL OF MAGNETIC RESONANCE, 1998, 132 (01) :150-153
[7]   Hemodynamics in the mouse aortic arch as assessed by MRI, ultrasound, and numerical modeling [J].
Feintuch, Akiva ;
Ruengsakulrach, Permyos ;
Lin, Amy ;
Zhang, Ji ;
Zhou, Yu-Qing ;
Bishop, Jonathon ;
Davidson, Lorinda ;
Courtman, David ;
Foster, F. Stuart ;
Steinman, David A. ;
Henkelman, R. Mark ;
Ethier, C. Ross .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2007, 292 (02) :H884-H892
[8]  
Gatehouse PD, 1999, MAGNET RESON MED, V41, P1023, DOI 10.1002/(SICI)1522-2594(199905)41:5<1023::AID-MRM22>3.0.CO
[9]  
2-1
[10]   Spatial and spectral heterogeneity of time-varying shear stress profiles in the carotid bifurcation by phase-contrast [J].
Gelfand, Bradley D. ;
Epstein, Frederick H. ;
Blackman, Brett R. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (06) :1386-1392