Usefulness of hybrid deformable image registration algorithms in prostate radiation therapy

被引:35
|
作者
Motegi, Kana [1 ,2 ]
Tachibana, Hidenobu [1 ,2 ]
Motegi, Atsushi [3 ]
Hotta, Kenji [1 ,2 ]
Baba, Hiromi [1 ,2 ]
Akimoto, Tetsuo [3 ]
机构
[1] Natl Canc Ctr Hosp East, Sect Radiat Safety & Qual Assurance, Kashiwa, Chiba, Japan
[2] Natl Canc Ctr, Particle Therapy Div, Exploratory Oncol Res & Clin Trial Ctr, Kashiwa, Chiba, Japan
[3] Natl Canc Ctr Hosp East, Div Radiat Oncol, Kashiwa, Chiba, Japan
来源
关键词
SEMINAL-VESICLES; RADIOTHERAPY; CT;
D O I
10.1002/acm2.12515
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the accuracy of commercially available hybrid deformable image registration (DIR) algorithms when using planning CT (pCT) and daily cone-beam computed tomography (CBCT) in radiation therapy for prostate cancer. The hybrid DIR algorithms in RayStation and MIM Maestro were evaluated. Contours of the prostate, bladder, rectum, and seminal vesicles (SVs) were used as region-of-interest (ROIs) to guide image deformation in the hybrid DIR and to compare the DIR accuracy. To evaluate robustness of the hybrid DIR for prostate cancer patients with organs with volume that vary on a daily basis, such as the bladder and rectum, the DIR algorithms were performed on ten pairs of CT volumes from ten patients who underwent prostate intensity-modulated radiation therapy or volumetric modulated arc therapy. In a visual evaluation, MIM caused unrealistic image deformation in soft tissues, organs, and pelvic bones. The mean dice similarity coefficient (DSC) ranged from 0.46 to 0.90 for the prostate, bladder, rectum, and SVs; the SVs had the lowest DSC. Target registration error (TRE) at the centroid of the ROIs was about 2 mm for the prostate and bladder, and about 6 mm for the rectum and SVs. RayStation did not cause unrealistic image deformation, and could maintain the shape of pelvic bones in most cases. The mean DSC and TRE at the centroid of the ROIs were about 0.9 and within 5 mm generally. In both software programs, the use of ROls to guide image deformation had the possibility to reduce any unrealistic image deformation and might be effective to keep the DIR physically reasonable. The pCT/CBCT DIR for the prostate cancer did not reduce the DIR accuracy because of the use of ROIs to guide the image deformation.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 50 条
  • [41] Deformable registration of the planning image (KVCT) and daily treatment images (MVCT) for Adaptive Radiation Therapy
    Lu, W
    Chen, Q
    Kupelian, P
    Langen, K
    Meeks, S
    Ruchala, K
    Olivera, G
    MEDICAL PHYSICS, 2005, 32 (06) : 2132 - 2132
  • [42] Deformable image registration of CT and truncated cone-beam CT for adaptive radiation therapy
    Zhen, Xin
    Yan, Hao
    Zhou, Linghong
    Jia, Xun
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (22): : 7979 - 7993
  • [43] Deformable Registration Using Edge Preserving Scale Space for Adaptive Image Guided Radiation Therapy
    Chen, J.
    Li, D.
    MEDICAL PHYSICS, 2011, 38 (06) : 3420 - +
  • [44] Is Deformable PET/CT Registration for Contouring Target Volume Superior to Rigid Image Registration in Lung Cancer Radiation Therapy?
    Dincbas, H. F.
    Oksuz, D. C.
    Ergen, S. A.
    Ozuynuk, G.
    Bol, Z.
    Bakir, A.
    Karacam, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S641 - S641
  • [45] A Novel Hybrid Model for Deformable Image Registration in Abdominal Procedures
    Huang, Xishi
    Babyn, Paul S.
    Looi, Thomas
    Kim, Peter C. W.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [46] Deformable image registration using improved hybrid elastic model
    Cai, ZF
    Jaeger, M
    Lu, HQ
    THIRD INTERNATIONAL SYMPOSIUM ON MULTISPECTRAL IMAGE PROCESSING AND PATTERN RECOGNITION, PTS 1 AND 2, 2003, 5286 : 145 - 150
  • [47] Adaptive RT for Head-and-Neck Cancer: The Usefulness of Deformable Image Registration
    Behrens, C. F.
    Eiland, R. B.
    Sjostrom, D.
    Maare, C.
    Paulsen, R. R.
    Samsoe, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S775 - S775
  • [48] Implementation and evaluation of various demons deformable image registration algorithms on a GPU
    Gu, Xuejun
    Pan, Hubert
    Liang, Yun
    Castillo, Richard
    Yang, Deshan
    Choi, Dongju
    Castillo, Edward
    Majumdar, Amitava
    Guerrero, Thomas
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01): : 207 - 219
  • [49] Evaluation of Five Commercially-Available Algorithms for Deformable Image Registration
    Shah, A.
    Pukala, J.
    Johnson, P.
    Staton, R.
    Meeks, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 399 - 399
  • [50] DEFORMABLE REGISTRATION IN PROSTATE RADIOTHERAPY
    Brock, K.
    Lee, J.
    Menard, C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S189 - S190