Usefulness of hybrid deformable image registration algorithms in prostate radiation therapy

被引:35
|
作者
Motegi, Kana [1 ,2 ]
Tachibana, Hidenobu [1 ,2 ]
Motegi, Atsushi [3 ]
Hotta, Kenji [1 ,2 ]
Baba, Hiromi [1 ,2 ]
Akimoto, Tetsuo [3 ]
机构
[1] Natl Canc Ctr Hosp East, Sect Radiat Safety & Qual Assurance, Kashiwa, Chiba, Japan
[2] Natl Canc Ctr, Particle Therapy Div, Exploratory Oncol Res & Clin Trial Ctr, Kashiwa, Chiba, Japan
[3] Natl Canc Ctr Hosp East, Div Radiat Oncol, Kashiwa, Chiba, Japan
来源
关键词
SEMINAL-VESICLES; RADIOTHERAPY; CT;
D O I
10.1002/acm2.12515
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the accuracy of commercially available hybrid deformable image registration (DIR) algorithms when using planning CT (pCT) and daily cone-beam computed tomography (CBCT) in radiation therapy for prostate cancer. The hybrid DIR algorithms in RayStation and MIM Maestro were evaluated. Contours of the prostate, bladder, rectum, and seminal vesicles (SVs) were used as region-of-interest (ROIs) to guide image deformation in the hybrid DIR and to compare the DIR accuracy. To evaluate robustness of the hybrid DIR for prostate cancer patients with organs with volume that vary on a daily basis, such as the bladder and rectum, the DIR algorithms were performed on ten pairs of CT volumes from ten patients who underwent prostate intensity-modulated radiation therapy or volumetric modulated arc therapy. In a visual evaluation, MIM caused unrealistic image deformation in soft tissues, organs, and pelvic bones. The mean dice similarity coefficient (DSC) ranged from 0.46 to 0.90 for the prostate, bladder, rectum, and SVs; the SVs had the lowest DSC. Target registration error (TRE) at the centroid of the ROIs was about 2 mm for the prostate and bladder, and about 6 mm for the rectum and SVs. RayStation did not cause unrealistic image deformation, and could maintain the shape of pelvic bones in most cases. The mean DSC and TRE at the centroid of the ROIs were about 0.9 and within 5 mm generally. In both software programs, the use of ROls to guide image deformation had the possibility to reduce any unrealistic image deformation and might be effective to keep the DIR physically reasonable. The pCT/CBCT DIR for the prostate cancer did not reduce the DIR accuracy because of the use of ROIs to guide the image deformation.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 50 条
  • [21] Deformable image registration applied to lung SBRT: Usefulness and limitations
    Sarrut, David
    Baudier, Thomas
    Ayadi, Myriam
    Tanguy, Ronan
    Rit, Simon
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 108 - 112
  • [22] Validation of three deformable image registration algorithms for the thorax
    Latifi, Kujtim
    Zhang, Geoffrey
    Stawicki, Marnix
    van Elmpt, Wouter
    Dekker, Andre
    Forster, Kenneth
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 19 - 30
  • [23] IMPROVEMENT OF ACCURACY IN DEFORMABLE REGISTRATION IN RADIATION THERAPY
    Ye, Xiaojing
    Chen, Yunmei
    2008 15TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-5, 2008, : 2420 - 2423
  • [24] Adaptive Radiation Therapy with Deformable Image Registration and 4D Dose Calculation
    Ali, I.
    Alsbou, N.
    Ahmad, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [25] Quantitative Evaluation of Deformable Image Registration in MRI- Guided Adaptive Radiation Therapy
    Mooney, K.
    Zhao, T.
    Duan, Y.
    Zhang, M.
    Green, O.
    Mutic, S.
    Yang, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3737 - 3737
  • [26] Assessment of Accuracy and Reproducibility of Automatic Deformable Image Registration for Head and Neck Radiation Therapy
    Speight, R.
    Perkinson, A.
    Lindsay, R.
    Artschan, R.
    Prestwich, R.
    Sykes, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S732 - S733
  • [27] An anthropomorphic abdominal phantom for deformable image registration accuracy validation in adaptive radiation therapy
    Liao, Yuliang
    Wang, Linjing
    Xu, Xiangdong
    Chen, Haibin
    Chen, Jiawei
    Zhang, Guoqian
    Lei, Huaiyu
    Wang, Ruihao
    Zhang, Shuxu
    Gu, Xuejun
    Zhen, Xin
    Zhou, Linghong
    MEDICAL PHYSICS, 2017, 44 (06) : 2369 - 2378
  • [28] Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy
    Lu, Weiguo
    Olivera, Gustavo H.
    Chen, Quan
    Ruchala, Kenneth J.
    Haimerl, Jason
    Meeks, Sanford L.
    Langen, Katja M.
    Kupelian, Patrick A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (17): : 4357 - 4374
  • [29] Region-based Correction of Deformable Image Registration Errors for Adaptive Radiation Therapy
    Zhong, H.
    Li, S.
    Wen, N.
    Chetty, I.
    Movsas, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S797 - S797
  • [30] Evaluation of Biomechanical Deformable Image Registration (DIR) in a Commercial Radiation Therapy Planning System
    Velec, M.
    Moseley, J. L.
    Svensson, S.
    Craig, T.
    Menard, C.
    Hardemark, B.
    Brock, K. K.
    Jaffray, D. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : S215 - S216