Usefulness of hybrid deformable image registration algorithms in prostate radiation therapy

被引:35
作者
Motegi, Kana [1 ,2 ]
Tachibana, Hidenobu [1 ,2 ]
Motegi, Atsushi [3 ]
Hotta, Kenji [1 ,2 ]
Baba, Hiromi [1 ,2 ]
Akimoto, Tetsuo [3 ]
机构
[1] Natl Canc Ctr Hosp East, Sect Radiat Safety & Qual Assurance, Kashiwa, Chiba, Japan
[2] Natl Canc Ctr, Particle Therapy Div, Exploratory Oncol Res & Clin Trial Ctr, Kashiwa, Chiba, Japan
[3] Natl Canc Ctr Hosp East, Div Radiat Oncol, Kashiwa, Chiba, Japan
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2019年 / 20卷 / 01期
关键词
SEMINAL-VESICLES; RADIOTHERAPY; CT;
D O I
10.1002/acm2.12515
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the accuracy of commercially available hybrid deformable image registration (DIR) algorithms when using planning CT (pCT) and daily cone-beam computed tomography (CBCT) in radiation therapy for prostate cancer. The hybrid DIR algorithms in RayStation and MIM Maestro were evaluated. Contours of the prostate, bladder, rectum, and seminal vesicles (SVs) were used as region-of-interest (ROIs) to guide image deformation in the hybrid DIR and to compare the DIR accuracy. To evaluate robustness of the hybrid DIR for prostate cancer patients with organs with volume that vary on a daily basis, such as the bladder and rectum, the DIR algorithms were performed on ten pairs of CT volumes from ten patients who underwent prostate intensity-modulated radiation therapy or volumetric modulated arc therapy. In a visual evaluation, MIM caused unrealistic image deformation in soft tissues, organs, and pelvic bones. The mean dice similarity coefficient (DSC) ranged from 0.46 to 0.90 for the prostate, bladder, rectum, and SVs; the SVs had the lowest DSC. Target registration error (TRE) at the centroid of the ROIs was about 2 mm for the prostate and bladder, and about 6 mm for the rectum and SVs. RayStation did not cause unrealistic image deformation, and could maintain the shape of pelvic bones in most cases. The mean DSC and TRE at the centroid of the ROIs were about 0.9 and within 5 mm generally. In both software programs, the use of ROls to guide image deformation had the possibility to reduce any unrealistic image deformation and might be effective to keep the DIR physically reasonable. The pCT/CBCT DIR for the prostate cancer did not reduce the DIR accuracy because of the use of ROIs to guide the image deformation.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 24 条
  • [1] MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS
    BALTER, JM
    SANDLER, HM
    LAM, K
    BREE, RL
    LICHTER, AS
    TENHAKEN, RK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01): : 113 - 118
  • [2] Analysis of prostate and seminal vesicle motion: Implications for treatment planning
    Beard, CJ
    Kijewski, P
    Bussiere, M
    Gelman, R
    Gladstone, D
    Shaffer, K
    Plunkett, M
    Costello, P
    Coleman, CN
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02): : 451 - 458
  • [3] Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task
    Brock, Kristy K.
    Mutic, Sasa
    McNutt, Todd R.
    Li, Hua
    Kessler, Marc L.
    [J]. MEDICAL PHYSICS, 2017, 44 (07) : E43 - E76
  • [4] Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy
    Deurloo, KEI
    Steenbakkers, RJHM
    Zijp, LJ
    de Bois, JA
    Nowak, PJCM
    Rasch, CRN
    van Herk, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (01): : 228 - 238
  • [5] Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning
    Fiorino, C
    Reni, M
    Bolognesi, A
    Cattaneo, GM
    Calandrino, R
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 47 (03) : 285 - 292
  • [6] Large deformation three-dimensional image registration in image-guided radiation therapy
    Foskey, M
    Davis, B
    Goyal, L
    Chang, S
    Chaney, E
    Strehl, N
    Tomei, S
    Rosenman, J
    Joshi, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (24) : 5869 - 5892
  • [7] Herk M, 1995, INT J RADIAT ONCOL, V33, P1311
  • [8] Evaluation of the tool "Reg Refine" for user-guided deformable image registration
    Johnson, Perry B.
    Padgett, Kyle R.
    Chen, Kuan L.
    Dogan, Nesrin
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 158 - 170
  • [9] Multi-institutional Validation Study of Commercially Available Deformable Image Registration Software for Thoracic Images
    Kadoya, Noriyuki
    Nakajima, Yujiro
    Saito, Masahide
    Miyabe, Yuki
    Kurooka, Masahiko
    Kito, Satoshi
    Fujita, Yukio
    Sasaki, Motoharu
    Arai, Kazuhiro
    Tani, Kensuke
    Yagi, Masashi
    Wakita, Akihisa
    Tohyama, Naoki
    Jingu, Keiichi
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : 422 - 431
  • [10] A novel approach for establishing benchmark CBCT/CT deformable image registrations in prostate cancer radiotherapy
    Kim, Jinkoo
    Kumar, Sanath
    Liu, Chang
    Zhong, Hualiang
    Pradhan, Deepak
    Shah, Mira
    Cattaneo, Richard
    Yechieli, Raphael
    Robbins, Jared R.
    Elshaikh, Mohamed A.
    Chetty, Indrin J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (22) : 8077 - 8097