The effect of cross-talk on MRI lesion numbers and volumes in multiple sclerosis using conventional and turbo spin-echo

被引:3
作者
Filippi, M
Yousry, TA
Rocca, MA
Pereira, C
Alkadhi, H
Comi, G
机构
[1] Univ Milan, MS Biosignal Anal Ctr, Dept Neurol, Osped San Raffaele,Sci Inst, Milan, Italy
[2] Univ Munich, Klinikum Grosshadern, Dept Diagnost Radiol, D-8000 Munich, Germany
来源
MULTIPLE SCLEROSIS | 1998年 / 4卷 / 06期
关键词
multiple sclerosis; magnetic resonance imaging; cross-talk; lesion volumes;
D O I
10.1191/135245898678845188
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We measured and compared lesion numbers and volumes Present on brain magnetic resonance imaging (MRI) scans of patients with multiple sclerosis (MS) acquired with contiguous (scheme A) and interleaved (scheme B) slice acquisition to evaluate whether there was a gain in sensitivity using the second pattern of acquisition and whether this counterbalanced the doubled acquisition time. Conventional spin-echo (CSE) sequences were performed for eight patients and turbo spin-echo (TSE) sequences for ten. Acquisition scheme B detected 3.8% more lesions than acquisition scheme A (the increase was 3.1% for CSE and 4.5% for TSE). These differences were not statistically significant No significant difference in lesion numbers was found when different lesion locations were also considered. Lesion volumes were significantly higher when scheme B was used (P=0.024). This was due to higher lesion volumes on TSE images (P=0.006), especially on even-numbered slices (P=0.008). Inter-slice cross-talk has a negligible effect on lesion numbers and volume estimates in MS for CSE sequence, whilst it cannot he negleted when TSE sequences ore used to measure MS lesion volume.
引用
收藏
页码:471 / 474
页数:4
相关论文
共 31 条
  • [21] Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI
    F. X. Aymerich
    C. Auger
    P. Alcaide-Leon
    D. Pareto
    E. Huerga
    J. F. Corral
    R. Mitjana
    J. Sastre-Garriga
    X. Montalban
    A. Rovira
    European Radiology, 2017, 27 : 1361 - 1368
  • [22] Comparison of HASTE with multiple signal averaging versus conventional turbo spin echo sequence: a new option for T2-weighted MRI of the female pelvis
    Takahiro Tsuboyama
    Oki Takei
    Atsuhiko Okada
    Toru Honda
    Keiko Kuriyama
    European Radiology, 2020, 30 : 3245 - 3253
  • [23] Comparison of HASTE with multiple signal averaging versus conventional turbo spin echo sequence: a new option for T2-weighted MRI of the female pelvis
    Tsuboyama, Takahiro
    Takei, Oki
    Okada, Atsuhiko
    Honda, Toru
    Kuriyama, Keiko
    EUROPEAN RADIOLOGY, 2020, 30 (06) : 3245 - 3253
  • [24] MRI of intracranial vertebral artery dissection: evaluation of intramural haematoma using a black blood, variable-flip-angle 3D turbo spin-echo sequence
    Takano, Koichi
    Yamashita, Shinnichi
    Takemoto, Koichiro
    Inoue, Tooru
    Kuwabara, Yasuo
    Yoshimitsu, Kengo
    NEURORADIOLOGY, 2013, 55 (07) : 845 - 851
  • [25] MRI of intracranial vertebral artery dissection: evaluation of intramural haematoma using a black blood, variable-flip-angle 3D turbo spin-echo sequence
    Koichi Takano
    Shinnichi Yamashita
    Koichiro Takemoto
    Tooru Inoue
    Yasuo Kuwabara
    Kengo Yoshimitsu
    Neuroradiology, 2013, 55 : 845 - 851
  • [26] The sensitivity of thin-slice fast spin echo, fast FLAIR and gadolinium-enhanced T1-weighted MRI sequences in detecting new lesion activity in multiple sclerosis
    Tubridy, N
    Molyneux, PD
    Moseley, IF
    Miller, DH
    JOURNAL OF NEUROLOGY, 1999, 246 (12) : 1181 - 1185
  • [27] Multiple sclerosis: interobserver agreement in reporting active lesions on serial brain MRI using conventional spin echo, fast spin echo, fast fluid-attenuated inversion recovery and post-contrast T1-weighted images
    M. Rovaris
    F. Barkhof
    S. Bastianello
    C. Gasperini
    N. Tubridy
    T. A. Yousry
    M. P. Sormani
    B. Viti
    D. H. Miller
    M. Filippi
    Journal of Neurology, 1999, 246 : 920 - 925
  • [28] Lesion load quantification on fast-flair, rapid acquisition relaxation-enhanced, and gradient spin echo brain MRI scans from multiple sclerosis patients
    Rovaris, M
    Rocca, MA
    Yousry, I
    Yousry, TA
    Colombo, B
    Comi, G
    Filippi, M
    MAGNETIC RESONANCE IMAGING, 1999, 17 (08) : 1105 - 1110
  • [29] Carotid Arterial Wall MRI at 3T Using 3D Variable-Flip-Angle Turbo Spin-Echo (TSE) with Flow-Sensitive Dephasing (FSD)
    Fan, Zhaoyang
    Zhang, Zhuoli
    Chung, Yiu-Cho
    Weale, Peter
    Zuehlsdorff, Sven
    Carr, James
    Li, Debiao
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 645 - 654
  • [30] A multiparametric alternative to short inversion-time inversion recovery for imaging inflammation: T2water and fat fraction measurement using chemical shift-encoded turbo spin-echo MRI
    Gollifer, Ruaridh M. M.
    Bray, Timothy J. P.
    Kruezi, Ariona
    Markus, Julia
    Choida, Varvara
    Hall-Craggs, Margaret A. A.
    Bainbridge, Alan
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (03) : 1010 - 1024