Extraction and retention of technetium-99m-ECD in human brain: Dynamic SPECT and oxygen-15-water PET studies

被引:0
作者
Ishizu, K
Yonekura, Y
Magata, Y
Okazawa, H
Fukuyama, H
Tanaka, F
Hattori, N
Kitano, H
Fujita, T
Tamaki, N
Konishi, J
机构
[1] KYOTO UNIV,FAC MED,DEPT NEUROL,KYOTO 60601,JAPAN
[2] FUKUI MED SCH,BIOMED IMAGING RES CTR,FUKUI 91011,JAPAN
关键词
technetium-99m-ECD; brain perfusion; SPECT; permeability surface area product;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The kinetic behavior of Tc-99m-ethyl cysteinate dimer (Tc-99m-ECD) in the human brain was investigated in six normal volunteers, Methods: Dynamic SPECT and a three-compartmental model were used to estimate the rate constants of Tc-99m-ECD in normal human brain. Extraction fraction (E), retention fraction (R) and permeability surface area product (PS product) of Tc-99m-ECD were calculated using the rate constants, Regional cerebral blood flow (rCBF) was measured by PET with O-15-water, Results: The rate constants in the cerebral cortex were estimated as 0.307 +/- 0.021 for K1 (influx constant), 0.201 +/- 0.047 for k2 (backdiffusion rate constant), 0.547 +/- 0.103 for k3 (lipophilic-to-hydrophilic conversion constant) and 0.0028 +/- 0.0012 for k5 (rate constant from lipophilic compartment to blood) al rCBF of 0.509 +/- 0.055 ml/g/min (mean +/- s.d.), The first-pass extraction, retention fraction and PS product were calculated as 0.608 +/- 0.069, 0.734 +/- 0.047 and 0.477 +/- 0.060, respectively. The first- pass extraction of Tc-99m-ECD decreased significantly with increases in rCBF, The retention fraction and PS product of Tc-99m-ECD did not show significant changes within the normal range of rCBF. The net extraction of (99m)c-ECD calculated from the static SPECT image obtained from 20 to 40 min was 0.358 +/- 0.039 in the cortex. Conclusion: Technetium-99m-ECD has a fairly high brain extraction, and its retention fraction and PS product appear to be independent of rCBF in the healthy human brain.
引用
收藏
页码:1600 / 1604
页数:5
相关论文
共 18 条
[1]   WEIGHTED LEAST-SQUARES TECHNIQUE FOR ANALYSIS OF KINETIC DATA AND ITS APPLICATION TO STUDY OF RENAL XENON-133 WASHOUT IN DOGS AND MAN [J].
DELL, RB ;
SCIACCA, R ;
LIEBERMAN, K ;
CASE, DB ;
CANNON, PJ .
CIRCULATION RESEARCH, 1973, 32 (01) :71-84
[2]  
FRIBERG L, 1994, J CEREBR BLOOD F MET, V14, pS19
[3]  
KNUDSEN GM, 1994, J CEREBR BLOOD F MET, V14, pS12
[4]   AN ALGORITHM FOR LEAST-SQUARES ESTIMATION OF NONLINEAR PARAMETERS [J].
MARQUARDT, DW .
JOURNAL OF THE SOCIETY FOR INDUSTRIAL AND APPLIED MATHEMATICS, 1963, 11 (02) :431-441
[5]   DETERMINATION OF FLOW AND RATE CONSTANTS IN A KINETIC-MODEL OF [TC-99M] HEXAMETHYL-PROPYLENE AMINE OXIME IN THE HUMAN-BRAIN [J].
MATSUDA, H ;
OBA, H ;
SEKI, H ;
HIGASHI, S ;
SUMIYA, H ;
TSUJI, S ;
TERADA, H ;
IMAI, K ;
SHIBA, K ;
MORI, H ;
HISADA, K .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (06) :S61-S68
[6]  
MURASE K, 1992, J NUCL MED, V33, P135
[7]  
RAICHLE ME, 1983, J NUCL MED, V24, P790
[8]  
ROCCO RJD, 1993, J NUCL MED, V34, P641
[9]   NONINVASIVE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW CHANGE WITH (H2O)-O-15 AND POSITRON EMISSION TOMOGRAPHY USING A MECHANICAL INJECTOR AND A STANDARD ARTERIAL INPUT FUNCTION [J].
SADATO, N ;
YONEKURA, Y ;
SENDA, M ;
MAGATA, Y ;
IWASAKI, Y ;
MATOBA, N ;
TSUCHIDA, T ;
TAMAKI, N ;
FUKUYAMA, H ;
SHIBASAKI, H ;
KONISHI, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) :703-710
[10]  