Simultaneous Determination of Vitamin D and Its Hydroxylated and Esterified Metabolites by Ultrahigh-Performance Supercritical Fluid Chromatography-Tandem Mass Spectrometry

被引:12
作者
Socas-Rodriguez, Barbara [1 ]
Pilarova, Veronika [1 ,2 ]
Sandahl, Margareta [1 ]
Holm, Cecilia [3 ]
Turner, Charlotta [1 ]
机构
[1] Lund Univ, Ctr Anal & Synth, Dept Chem, S-22100 Lund, Sweden
[2] Charles Univ Prague, Fac Pharm Hradec Kralove, Dept Analyt Chem, Hradec Kralove 50005, Czech Republic
[3] Lund Univ, Fac Med, Dept Expt Med Sci, S-22100 Lund, Sweden
关键词
FAT-SOLUBLE VITAMINS; SERUM; MILK;
D O I
10.1021/acs.analchem.1c04016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, an analytical method has been developed that, for the first time, allows simultaneous determination of vitamin D-2 and vitamin D-3 along with their hydroxylated and esterified forms. A group of 12 vitamin D analogues including vitamin D-2 and vitamin D-3, seven hydroxylated metabolites, and three ester forms were separated in a single 8.0 min run using ultrahigh-performance supercritical fluid chromatography coupled with triple quadrupole tandem mass spectrometry. Electrospray ionization and atmospheric pressure chemical ionization were investigated as ion sources, of which the latter showed a higher ionization efficiency. Chromatographic conditions were thoroughly evaluated by a step-by-step method, whereas an experimental design was applied for the optimization of the ionization parameters. Calibration and repeatability studies were carried out to validate the instrumental methodology showing determination coefficients higher than 0.9992 and good intra- and interday precision with relative standard deviations for areas and retention times lower than 10 and 2.1%, respectively, for all target analytes. Limits of quantification were below 3.03 mu g/L for all compounds. The methodology was then validated and applied for the evaluation of human plasma samples in order to demonstrate its applicability to the analysis of vitamin D analogues in biological samples. Samples of five individuals were analyzed. Results show that linoleate-D-3, vitamin D-2, vitamin D-3, 25-hydroxyvitamin D-2, 24,25-dihydroxyvitamin D-3, and 1,25-dihydroxyvitamin D-3 could be detected in most samples, while the two latter also were quantified in all analyzed samples.
引用
收藏
页码:3065 / 3073
页数:9
相关论文
共 31 条
[1]   A rapid analytical method for cholecalciferol (vitamin D3) in fortified infant formula, milk and milk powder using Diels-Alder derivatisation and liquid chromatography-tandem mass spectrometric detection [J].
Abernethy, Grant A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (05) :1433-1440
[2]   Measurement of plasma 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in population of patients with cardiovascular disease by UPLC-MS/MS method [J].
Abouzid, Mohamed ;
Karazniewicz-Lada, Marta ;
Pawlak, Kornel ;
Burchardt, Pawel ;
Kruszyna, Lukasz ;
Glowka, Franciszek .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1159
[3]   Development and optimization of an LC-MS/MS-based method for simultaneous quantification of vitamin D2, vitamin D3, 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 [J].
Adamec, Jiri ;
Jannasch, Amber ;
Huang, Jianjie ;
Hohman, Emily ;
Fleet, James C. ;
Peacock, Munro ;
Ferruzzi, Mario G. ;
Martin, Berdine ;
Weaver, Connie M. .
JOURNAL OF SEPARATION SCIENCE, 2011, 34 (01) :11-20
[4]   Hyphenation of packed column supercritical fluid chromatography with mass spectrometry: where are we and what are the remaining challenges? [J].
Akbal, Laura ;
Hopfgartner, Gerard .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (25) :6667-6677
[5]   Effects of liquid post-column addition in electrospray ionization performance in supercritical fluid chromatography-mass spectrometry [J].
Akbal, Laura ;
Hopfgartner, Gerard .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1517 :176-184
[6]   Measurement of serum 3-epi-25-hydroxyvitamin D3, 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in infant, paediatric and adolescent populations of Korea using ultra-performance liquid chromatography-tandem mass spectrometry [J].
Cho, Sung E. ;
Kim, Sollip ;
Kim, Young D. ;
Lee, Hyojung ;
Seo, Dong H. ;
Song, Junghan ;
Um, Tae H. ;
Cho, Chong R. ;
Kim, Nam H. ;
Hwang, Jong H. .
ANNALS OF CLINICAL BIOCHEMISTRY, 2017, 54 (05) :530-538
[7]   Quantitative determination of vitamin D metabolites in plasma using UHPLC-MS/MS [J].
Ding, Shujing ;
Schoenmakers, Inez ;
Jones, Kerry ;
Koulman, Albert ;
Prentice, Ann ;
Volmer, Dietrich A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (02) :779-789
[8]  
EC, 2002, Official Journal of the European Communities
[9]   Determination of vitamin D and its metabolites [J].
Farrell, Christopher-John ;
Herrmann, Markus .
BEST PRACTICE & RESEARCH CLINICAL ENDOCRINOLOGY & METABOLISM, 2013, 27 (05) :675-688
[10]   Total 25-Hydroxyvitamin D Determination by an Entry Level Triple Quadrupole Instrument: Comparison between Two Commercial Kits [J].
Gervasoni, Jacopo ;
Cocci, Andrea ;
Zuppi, Cecilia ;
Persichilli, Silvia .
BIOMED RESEARCH INTERNATIONAL, 2013, 2013