Three-dimensional numerical simulation of blood flow in the aortic arch during cardiopulmonary bypass

被引:55
作者
Tokuda, Yoshiyuki [1 ]
Song, Min-Ho [1 ]
Ueda, Yuichi [2 ]
Usui, Akihiko [2 ]
Akita, Toshiaki [2 ]
Yoneyama, Shigeru [3 ]
Maruyama, Shigeru [4 ]
机构
[1] Gifu Prefectural Tajimi Hosp, Dept Cardiovasc Surg, Gifu 5078522, Japan
[2] Nagoya Univ, Grad Sch Med, Dept Cardiothorac Surg, Nagoya, Aichi 4668550, Japan
[3] Maxnet Co Ltd, Nakano Ku, Tokyo 1650001, Japan
[4] Numcraft Inc, Kanagawa 2400112, Japan
关键词
cardiopulmonary bypass; computer simulation;
D O I
10.1016/j.ejcts.2007.11.021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To better understand the mechanism of stroke during cardiopulmonary bypass, it is necessary to obtain information on the location of turbulence, watt pressure, and flow distribution within the aortic arch. Methods: Blood flow was numerically simulated using the finite element method in the following representative case: a curved arterial cannula was inserted into the anterior wall of the distal ascending aorta 2 cm below the orifice of brachiocephalic artery. Perfusion was performed, with a bypass flow index of 2.5 1 min(-1) m(-2). Computational grids, consisting of 1,493,297 tetrahedral elements, were generated. Results: The highest wall pressure (3104.8 Pa) was observed at the superior-posterior watt of the aorta below the orifice of the brachiocephalic artery where jet flow impingement occurred. The maximum watt shear stress was 25.1 Pa. High velocity vortex started below the orifice of the brachiocephalic artery. The turbulent flows continued along the posterior watt and then mainly flowed off into the left subclavian artery. Therefore, in the present case, an embolic event in the territory of the left subclavian artery could occur if a plaque was present at the superior-posterior wall of the aorta below the orifice of the brachiocephalic artery. The flow rates in each of the branches were 132, 613, 175, and 821 ml/min for the right subclavian, right common carotid, left common carotid, and left subclavian artery, respectively. Conclusion: This study confirmed that blood flow during cardiopulmonary bypass can be simulated and visualized. Computational fluid dynamics could be applied in the future to assess an individual's risk of stroke. Further multiple representative cases need to be simulated. (c) 2007 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:164 / 167
页数:4
相关论文
共 15 条
[1]   In vivo basal ganglia volumetry through application of NURBS models to MR images [J].
Anastasi, Giuseppe ;
Cutroneo, Giuseppina ;
Tomasello, Francesco ;
Lucerna, Sebastiano ;
Vitetta, AntonGiulio ;
Bramanti, Placido ;
Di Bella, Paolo ;
Parenti, Anna ;
Porzionato, Andrea ;
Macchi, Veronica ;
De Caro, Raffaele .
NEURORADIOLOGY, 2006, 48 (05) :338-345
[2]   Posterior distribution of infarcts in strokes related to cardiac operations [J].
Barbut, D ;
Grassineau, D ;
Lis, E ;
Heier, L ;
Hartman, GS ;
Isom, OW .
ANNALS OF THORACIC SURGERY, 1998, 65 (06) :1656-1659
[3]   Patient-specific computational modeling of cerebral aneurysms with multiple avenues of flow from 3D rotational angiography images [J].
Castro, Marcelo A. ;
Putman, Christopher M. ;
Cebral, Juan R. .
ACADEMIC RADIOLOGY, 2006, 13 (07) :811-821
[4]  
Fung YC., 1997, BIOMECHANICS CIRCULA, P108, DOI DOI 10.1007/978-1-4757-2696-1_3
[5]   Echocardiographic comparison of the standard end-hole cannula, the soft-flow cannula, and the dispersion cannula during perfusion into the aortic arch [J].
Grooters, RK ;
Steeg, DAV ;
Stewart, MJ ;
Thieman, KC ;
Schneider, RF .
ANNALS OF THORACIC SURGERY, 2003, 75 (06) :1919-1923
[6]   EFFECT OF CANNULA LENGTH ON AORTIC-ARCH FLOW - PROTECTION OF THE ATHEROMATOUS AORTIC-ARCH [J].
GROSSI, EA ;
KANCHUGER, MS ;
SCHWARTZ, DS ;
MCLOUGHLIN, DE ;
LEBOUTILLIER, M ;
RIBAKOVE, GH ;
MARSCHALL, KE ;
GALLOWAY, AC ;
COLVIN, SB .
ANNALS OF THORACIC SURGERY, 1995, 59 (03) :710-712
[7]  
HANAIZUMI H, 2002, INFORM COMMUN ENG, V101, P89
[8]   Surface triangulation for polygonal models based on CAD data [J].
Ito, Y ;
Nakahashi, K .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2002, 39 (01) :75-96
[9]   Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta [J].
May-Newman, K ;
Hillen, B ;
Dembitsky, W .
ASAIO JOURNAL, 2006, 52 (02) :132-139
[10]   3-D numerical simulation of blood flow through models of the human aorta [J].
Morris, L ;
Delassus, P ;
Callanan, A ;
Walsh, M ;
Wallis, F ;
Grace, P ;
McGloughlin, T .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (05) :767-775