Validation of an HPLC-MS-MS Method for the Determination of Urinary S-Benzylmercapturic Acid and S-Phenylmercapturic Acid

被引:14
|
作者
B'Hymer, C. [1 ]
机构
[1] NIOSH, US Dept HHS, Ctr Dis Control, Div Appl Res & Technol,Taft Lab C 23, Cincinnati, OH 45226 USA
关键词
CHROMATOGRAPHY-MASS SPECTROMETRY; OCCUPATIONAL-EXPOSURE; INDUSTRIAL-CHEMICALS; BENZENE METABOLITES; LC-MS; LIQUID; BIOMARKERS; TOLUENE; QUANTIFICATION; SOLVENTS;
D O I
10.1093/chrsci/49.7.547
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatography-tandem mass spectrometric (HPLC-MS-MS) method is presented and evaluated for the determination of S-benzylmercapturic acid (S-BMA) and S-phenylmercapturic acid (S-PMA) in human urine. Both of these compounds are important for occupational health owing to their use as biomarkers of exposure to toluene and benzene, respectively. Toluene is used extensively as a solvent, and the health hazards of benzene have been well established. The optimized urine sample preparation scheme consists of solid-phase extraction (SPE) followed by an acetone wash. The chromatographic analysis consists of a reversed-phase gradient system, which uses electrospray ionization in negative-ion mode with a triplequadrupole mass spectrometric detector. Accuracy and precision of this method are demonstrated by a series of recovery studies of spiked human urine and synthetic urine substitute. Spike levels at 1, 2, 6, 8, and 30 ng/mL for both analytes demonstrate average recoveries (accuracy) ranging from 99 to 110%. Precision as measured by the relative standard deviation (%RSD) of multiple samples (n = 9) at each concentration level was 5.3% or less for both analytes in urine. The limit of detection (LOD) is approximately 0.2 ng/mL for S-BMA and S-PMA. This data, other figures of merit and other factors, such as ion suppression of the electrospray ionization source, are discussed.
引用
收藏
页码:547 / 553
页数:7
相关论文
共 50 条
  • [41] The validation & verification of an LC/MS method for the determination of total docosahexaenoic acid concentrations in canine blood serum
    Dillon, Gerald Patrick
    Keegan, Jason D.
    Wallace, Geoff
    Yiannikouris, Alexandros
    Moran, Colm Anthony
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2018, 95 : 198 - 203
  • [42] Characterization of lysophosphatidic acid subspecies produced by autotaxin using a modified HPLC ESI-MS/MS method
    Wijesinghe, Dayanjan S.
    Mayton, Eric K.
    Mietla, Jennifer A.
    Mukherjee, Abir
    Wu, Jinhua
    Fang, Xianjun
    Chalfant, Charles E.
    ANALYTICAL METHODS, 2011, 3 (12) : 2822 - 2828
  • [43] The validation and verification of an LC/MS method for the determination of total docosahexaenoic acid concentrations in canine blood serum
    Dillon, G.
    Keegan, J.
    Wallace, G.
    Jacques, K.
    Yiannikouris, A.
    Moran, C.
    JOURNAL OF ANIMAL SCIENCE, 2018, 96 : 156 - 157
  • [44] Development, validation and application of an HPLC-MS/MS method for the determination of fentanyl and nor-fentanyl in human plasma and saliva
    Bista, Sudeep R.
    Lobb, Michael
    Haywood, Alison
    Hardy, Janet
    Tapuni, Angela
    Norris, Ross
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 960 : 27 - 33
  • [45] LC-MS/MS method for simultaneous determination of valproic acid and major metabolites in human plasma
    Gao, Shouhong
    Miao, Haijun
    Tao, Xia
    Jiang, Bo
    Xiao, Ying
    Cai, Fei
    Yun, Yunlei
    Li, Jingxian
    Chen, Wansheng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (21): : 1939 - 1944
  • [46] Development and validation of a reliable LC-MS/MS method for quantitative analysis of usnic acid in Cladonia uncialis
    Sveshnikova, Natalia
    Yuan, Tao
    Warren, Jamie M.
    Piercey-Normore, Michele D.
    BMC RESEARCH NOTES, 2019, 12 (01)
  • [47] A comprehensive study for the validation of a LC-MS/MS method for the determination of free and total forms of urinary cortisol and its metabolites
    Cuzzola, Angela
    Mazzini, Francesco
    Petri, Antonella
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 94 : 203 - 209
  • [48] Activated carbon/diatomite-based magnetic nanocomposites for magnetic solid-phase extraction of S-phenylmercapturic acid from human urine
    Shan, Xiaoyue
    Tan, Siwei
    Shi, Yanpeng
    Shao, Ji
    Su, Kewen
    Zhang, Ling
    Feng, Hui
    Ye, Haipeng
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (07)
  • [49] A dispersive liquid-liquid microextraction method for determination of bongkrekic acid in plasma by LC-MS/MS
    Xu, Xiumin
    Fang, Lei
    Lv, Fen
    Liu, Rui
    Huang, Xiangdong
    Huang, Weixiong
    Long, Chaoyang
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2021, 44 (5-6) : 279 - 284
  • [50] HPLC-MS/MS method for the simultaneous quantification of desmethylmebeverine acid, mebeverine acid and mebeverine alcohol in human plasma along with its application to a pharmacokinetics study
    Moskaleva, Natalia E.
    Baranov, Pavel A.
    Mesonzhnik, Natalia V.
    Appolonova, Svetlana A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 138 : 118 - 125