Validation of an HPLC-MS-MS Method for the Determination of Urinary S-Benzylmercapturic Acid and S-Phenylmercapturic Acid

被引:14
|
作者
B'Hymer, C. [1 ]
机构
[1] NIOSH, US Dept HHS, Ctr Dis Control, Div Appl Res & Technol,Taft Lab C 23, Cincinnati, OH 45226 USA
关键词
CHROMATOGRAPHY-MASS SPECTROMETRY; OCCUPATIONAL-EXPOSURE; INDUSTRIAL-CHEMICALS; BENZENE METABOLITES; LC-MS; LIQUID; BIOMARKERS; TOLUENE; QUANTIFICATION; SOLVENTS;
D O I
10.1093/chrsci/49.7.547
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatography-tandem mass spectrometric (HPLC-MS-MS) method is presented and evaluated for the determination of S-benzylmercapturic acid (S-BMA) and S-phenylmercapturic acid (S-PMA) in human urine. Both of these compounds are important for occupational health owing to their use as biomarkers of exposure to toluene and benzene, respectively. Toluene is used extensively as a solvent, and the health hazards of benzene have been well established. The optimized urine sample preparation scheme consists of solid-phase extraction (SPE) followed by an acetone wash. The chromatographic analysis consists of a reversed-phase gradient system, which uses electrospray ionization in negative-ion mode with a triplequadrupole mass spectrometric detector. Accuracy and precision of this method are demonstrated by a series of recovery studies of spiked human urine and synthetic urine substitute. Spike levels at 1, 2, 6, 8, and 30 ng/mL for both analytes demonstrate average recoveries (accuracy) ranging from 99 to 110%. Precision as measured by the relative standard deviation (%RSD) of multiple samples (n = 9) at each concentration level was 5.3% or less for both analytes in urine. The limit of detection (LOD) is approximately 0.2 ng/mL for S-BMA and S-PMA. This data, other figures of merit and other factors, such as ion suppression of the electrospray ionization source, are discussed.
引用
收藏
页码:547 / 553
页数:7
相关论文
共 50 条
  • [21] Identification of S-phenylmercapturic acid using heterometallic Zn-Eu MOF as a fluorescence sensor
    Li, Wenting
    Li, Dechao
    Yang, Yefang
    Su, Shuai
    Qie, Shaowen
    Jia, Yuejiao
    Hu, Ming
    JOURNAL OF MOLECULAR STRUCTURE, 2025, 1321
  • [22] Development and validation of a UPLC-MS/MS method for the simultaneous determination of gamma-aminobutyric acid and glutamic acid in human plasma
    de Bie, Tessa H.
    Witkamp, Renger F.
    Jongsma, Maarten A.
    Balvers, Michiel G. J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1164
  • [23] Benzene Uptake and Glutathione S-transferase T1 Status as Determinants of S-Phenylmercapturic Acid in Cigarette Smokers in the Multiethnic Cohort
    Haiman, Christopher A.
    Patel, Yesha M.
    Stram, Daniel O.
    Carmella, Steven G.
    Chen, Menglan
    Wilkens, Lynne R.
    Le Marchand, Loic
    Hecht, Stephen S.
    PLOS ONE, 2016, 11 (03):
  • [24] Analytical validation and clinical application of urinary vanillylmandelic acid and homovanillic acid by LC-MS/MS for diagnosis of neuroblastoma
    Shen, Ying
    Li, Huijun
    Lu, Jie
    Luo, Xia
    Guan, Qing
    Cheng, Liming
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (06)
  • [25] New fully automated gas chromatographic analysis of urinary S-phenylmercapturic acid in isotopic dilution using negative chemical ionization with isobutane as reagent gas
    Dugheri, Stefano
    Mucci, Nicola
    Cappelli, Giovanni
    Bonari, Alessandro
    Campagna, Marcello
    Arcangeli, Giulio
    Bartolucci, Gianluca
    JOURNAL OF MASS SPECTROMETRY, 2020, 55 (07):
  • [26] Development and validation of a simple HPLC-MS/MS method for the quantification of methylmalonic acid in human serum without a derivatization step
    Hofmann, Sabrina
    Gebauer, Julian
    Krnac, Dusan
    Prantz, Anja
    Reiffova, Katarina
    Rolinski, Boris
    Serbin, Rastislav
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (08)
  • [27] Estimation of toluene exposure in air from BMA (S-benzylmercapturic acid) urinary measures using a reverse dosimetry approach based on physiologically pharmacokinetic modeling
    Tohon, Honesty
    Valcke, Mathieu
    Aranda-Rodriguez, Rocio
    Nong, Andy
    Haddad, Sami
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2021, 120
  • [28] Matrix Effect in the Quantitative Determination of Mandelic and Phenylglyoxylic Acid in Urine Samples by HPLC-MS/MS with Isotopic Dilution
    Paci, E.
    Pigini, D.
    Caporossi, L.
    De Rosa, M.
    Santoro, A.
    Sisto, R.
    Papaleo, B.
    Tranfo, G.
    CURRENT ANALYTICAL CHEMISTRY, 2013, 9 (03) : 439 - 446
  • [29] Development and Validation of an LC/MS/MS Method for Determination of Valproic Acid and Its Metabolite 2-Propyl-4-pentenoic Acid in Monkey Plasma
    Hwang, Kyunghwa
    Song, Sun-Sook
    Lee, Ju-Hee
    Shin, Min-Chul
    Seo, Jong-Su
    JOURNAL OF THE KOREAN SOCIETY FOR APPLIED BIOLOGICAL CHEMISTRY, 2012, 55 (01): : 13 - 17
  • [30] HPLC-APCI-MS/MS method development and validation for determination of tocotrienols in human breast adipose tissue
    Bartosinska, Ewa
    Jacyna, Julia
    Borsuk-De Moor, Agnieszka
    Kaliszan, Michal
    Kruszewski, Wieslaw Janusz
    Jankowski, Zbigniew
    Siluk, Danuta