Localization of cerebrospinal fluid leaks by gadolinium-enhanced magnetic resonance cisternography: A 5-year single-center experience

被引:45
作者
Aydin, Kubilay [1 ]
Terzibasioglu, Ege [2 ]
Sencer, Serra [1 ]
Sencer, Altay [3 ]
Suoglu, Yusufhan [4 ]
Karasu, Aykut [3 ]
Kiris, Talat [3 ]
Turantan, M. Inan [3 ]
机构
[1] Istanbul Univ, Istanbul Med Sch, Dept Neuroradiol, Istanbul, Turkey
[2] Istanbul Univ, Istanbul Med Sch, Dept Radiol, Istanbul, Turkey
[3] Istanbul Univ, Istanbul Med Sch, Dept Neurosurg, Istanbul, Turkey
[4] Istanbul Univ, Istanbul Med Sch, Dept Otolaryngol, Istanbul, Turkey
关键词
cerebrospinal fluid rhinorrhea; cisternography; gadolinium; magnetic resonance imaging; safety; sensitivity;
D O I
10.1227/01.neu.0000317306.39203.24
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Intrathecal gadolinium (Gd)-enhanced magnetic resonance (MR) cisternography is a newly introduced imaging method. Two main objectives of this study were to investigate the sensitivity of Gd-enhanced MR cisternography for presurgical localization of cerebrospinal fluid (CSF) leaks in patients with CSF rhinorrhea and to study the potential long-term adverse effects of intrathecal Gd application. METHODS: Fifty-one patients (19 women; mean age, 36.2 yr) with CSF rhinorrhea were included in the study. A total of 0.5 ml of Gd was injected into the lumbar subarachnoid space. T1-weighted MR cisternographic images were obtained to detect CSF leakage. The patient's neurological states and vital signs were recorded for the first 24 hours after the procedure. Neurological evaluations were repeated 1, 3, and 12 months after the procedure. The patients were followed for at least 3 years with annual neurological examinations. RESULTS: Gd-enhanced MR cisternography demonstrated CSF leaks in 43 of the 51 patients. The sensitivity of Gd-enhanced MR cisternography for localization of CSF leaks was 84%. Forty-four patients underwent surgery to repair dural tears. Surgical findings confirmed the results of Gd-enhanced cisternography in 43 of the 44 patients who underwent surgery (98%). Eight patients with negative Gd-enhanced MR cisternography had no active rhinorrhea at the time of procedure, and seven of them did not need surgery. None of the patients developed an acute adverse reaction that could be attributed to the procedure. None of the patients developed any neurological symptoms or signs caused by intrathecal Gd injection during a mean follow-up period of 4.12 years. CONCLUSION: Gd-enhanced MR cisternography is a sensitive and safe imaging method for detection of CSF leaks in patients with rhinorrhea.
引用
收藏
页码:584 / 589
页数:6
相关论文
共 30 条
  • [1] Intrathecal administration of gadopentetate dimeglumine for MR cisternography of nasoethmoidal CSF fistula
    Arbelaez, Andres
    Medina, Elcy
    Rodriguez, Margarita
    Londono, Ana C.
    Castillo, Mauricio
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (06) : W560 - W564
  • [2] Gadolinium encephalopathy due to accidental intrathecal administration of gadopentetate dimeglumine
    Arlt, Soenke
    Cepek, Lukas
    Rustenbeck, Hans Heino
    Prange, Hilmar
    Reimers, Carl Detlev
    [J]. JOURNAL OF NEUROLOGY, 2007, 254 (06) : 810 - 812
  • [3] MRI cisternography with gadolinium-containing contrast medium: its role, advantages and limitations in the investigation of rhinorrhoea
    Aydin, K
    Guven, K
    Sencer, S
    Jinkins, JR
    Minareci, O
    [J]. NEURORADIOLOGY, 2004, 46 (01) : 75 - 80
  • [4] EVALUATION OF CSF RHINORRHEA BY COMPUTERIZED-TOMOGRAPHY WITH METRIZAMIDE
    CHOW, JM
    GOODMAN, D
    MAFEE, MF
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1989, 100 (02) : 99 - 105
  • [5] CT CISTERNOGRAPHY IN THE INVESTIGATION OF CEREBROSPINAL-FLUID RHINORRHEA
    COLQUHOUN, IR
    [J]. CLINICAL RADIOLOGY, 1993, 47 (06) : 403 - 408
  • [6] CEREBROSPINAL-FLUID RHINORRHEA - DEPICTION WITH MR CISTERNOGRAPHY IN DOGS
    DICHIRO, G
    GIRTON, ME
    FRANK, JA
    DIETZ, MJ
    GANSOW, OA
    WRIGHT, DC
    DWYER, AJ
    [J]. RADIOLOGY, 1986, 160 (01) : 221 - 222
  • [7] MR CISTERNOGRAPHY AND MYELOGRAPHY WITH GD-DTPA IN MONKEYS
    DICHIRO, G
    KNOP, RH
    GIRTON, ME
    DWYER, AJ
    DOPPMAN, JL
    PATRONAS, NJ
    GANSOW, OA
    BRECHBIEL, MW
    BROOKS, RA
    [J]. RADIOLOGY, 1985, 157 (02) : 373 - 377
  • [8] MR cisternography: a new method for the diagnosis of CSF fistulae
    Eberhardt, KEW
    Hollenbach, HP
    Deimling, M
    Tomandl, BF
    Huk, WJ
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (09) : 1485 - 1491
  • [9] El Gammal T, 1998, AM J NEURORADIOL, V19, P627
  • [10] ELGAMMAL T, 1994, AM J NEURORADIOL, V15, P1647