摘要
The post-fire performance of concrete-filled stainless steel tubular (CFSST) columns subjected to an entire loading-fire history, including four characteristic phases: (i) ambient temperature loading, (ii) heating, (iii) cooling with constant external loads, and (iv) post-fire loading, is investigated in this paper. Sequentially coupled thermal-stress analyses are performed using ABAQUS to establish the temperature field and structural response of CFSST columns. To improve the precision of the finite element analysis (FEA) models, the influence of moisture on the thermal conductivity and specific heat of the concrete in the heating and cooling phases is considered by using subroutines. Existing fire and post-fire test data on CFSST columns are used to validate the FEA modelling. Comparisons between FEA and test results indicate that the accuracy of the model is acceptable; the FEA model is then extended to simulate CFSST columns subjected to the four characteristic phases. The behaviour of the CFSST columns during the four characteristic phases is explained by analysis of the temperature distribution, load versus axial deformation relations, failure modes and internal force redistribution. The excellent post-fire performance of CFSST columns is examined in comparison with traditional concrete-filled carbon steel tubular (CFST) columns with the same total cross-sectional area. The residual strength index is studied with respect to a series of parametric analyses. It is found that the residual strength of CFSST columns is higher than that of CFST columns after the same fire exposure, and that the diameter of the stainless steel tube, slenderness, heating time ratio and load ratio have a significant influence on the residual strength index.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] ANALYTICAL BEHAVIOUR OF CONCRETE-FILLED DOUBLE SKIN STEEL TUBULAR STUB COLUMNS AFTER EXPOSURE TO FIRE
    Yu, Xin
    Tao, Zhong
    Han, Lin-Hai
    Uy, Brian
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 2268 - 2273
  • [22] Study on the fire performance of concrete-filled double-skin tubular columns with external stainless steel tubes
    Li J.-Q.
    Wang R.
    Zhao H.
    Wang H.-W.
    Gongcheng Lixue/Engineering Mechanics, 2020, 37 (10): : 125 - 133
  • [23] Performance of Steel-Reinforced Concrete-Filled Stainless Steel Tubular Columns at Elevated Temperature
    Tan, Qinghua
    Gardner, Leroy
    Han, Linhai
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2019, 19 (01)
  • [24] Hysteresis performance of section steel reinforced concrete-filled rectangular stainless steel tubular columns
    Enpu Xie
    Yang Wang
    Yibei Bao
    Kun Huang
    Xianjiang Zhang
    SN Applied Sciences, 2023, 5
  • [25] Hysteresis performance of section steel reinforced concrete-filled rectangular stainless steel tubular columns
    Xie, Enpu
    Wang, Yang
    Bao, Yibei
    Huang, Kun
    Zhang, Xianjiang
    SN APPLIED SCIENCES, 2023, 5 (06):
  • [26] Fire behaviour of fire-protected concrete-filled steel tubular columns
    Lou, Guo-Biao
    Tan, Rui-Xin
    Qi, Hong-Hui
    Rao, Wen-Ting
    Huang, Dai-Fa
    Zhao, Xin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 226
  • [27] Experimental residual capacity of steel-reinforced concrete-filled steel tubular stub columns after fire exposure
    Medall, D.
    Ibanez, C.
    Albero, V.
    Espinos, A.
    Romero, M. L.
    THIN-WALLED STRUCTURES, 2023, 189
  • [28] Eccentric compressive behavior of square concrete-filled stainless steel tube (CFSST) stub columns
    Tang, Hongyuan
    Hou, Linjian
    Yuan, Zhijun
    Jia, Yigang
    Wang, Yuzhuo
    STRUCTURES, 2023, 55 : 1920 - 1935
  • [29] Performance of recycled aggregate concrete-filled square steel tubular columns exposed to fire
    Yang, You-Fu
    Zhang, Lei
    Dai, Xianghe
    ADVANCES IN STRUCTURAL ENGINEERING, 2017, 20 (09) : 1340 - 1356
  • [30] Tests on plain and steel fiber concrete-filled stainless steel tubular columns
    Tokgoz, Serkan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 114 : 129 - 135