Performance of concrete-filled stainless steel tubular (CFSST) columns after exposure to fire

被引:30
|
作者
Tan, Qing-Hua [1 ]
Gardner, Leroy [2 ]
Han, Lin-Hai [3 ]
Song, Tian-Yi [4 ]
机构
[1] Natl Univ Def Technol, Coll Aerosp Sci & Engn, Changsha, Peoples R China
[2] Imperial Coll London, Dept Civil & Environm Engn, London, England
[3] Tsinghua Univ, Dept Civil Engn, Beijing, Peoples R China
[4] Beijing Univ Technol, Coll Architecture & Civil Engn, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
Concrete-filled stainless steel tubular (CFSST) columns; Post-fire; Finite element analysis (FEA) modelling; Residual strength; Fire safety engineering; COOLING BEHAVIOR; STUB COLUMNS; DESIGN; STRENGTH;
D O I
10.1016/j.tws.2020.106629
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The post-fire performance of concrete-filled stainless steel tubular (CFSST) columns subjected to an entire loading-fire history, including four characteristic phases: (i) ambient temperature loading, (ii) heating, (iii) cooling with constant external loads, and (iv) post-fire loading, is investigated in this paper. Sequentially coupled thermal-stress analyses are performed using ABAQUS to establish the temperature field and structural response of CFSST columns. To improve the precision of the finite element analysis (FEA) models, the influence of moisture on the thermal conductivity and specific heat of the concrete in the heating and cooling phases is considered by using subroutines. Existing fire and post-fire test data on CFSST columns are used to validate the FEA modelling. Comparisons between FEA and test results indicate that the accuracy of the model is acceptable; the FEA model is then extended to simulate CFSST columns subjected to the four characteristic phases. The behaviour of the CFSST columns during the four characteristic phases is explained by analysis of the temperature distribution, load versus axial deformation relations, failure modes and internal force redistribution. The excellent post-fire performance of CFSST columns is examined in comparison with traditional concrete-filled carbon steel tubular (CFST) columns with the same total cross-sectional area. The residual strength index is studied with respect to a series of parametric analyses. It is found that the residual strength of CFSST columns is higher than that of CFST columns after the same fire exposure, and that the diameter of the stainless steel tube, slenderness, heating time ratio and load ratio have a significant influence on the residual strength index.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Impact and post-impact behaviours of steel-reinforced concrete-filled steel tubular columns after exposure to fire
    Ji, Sun-Hang
    Wang, Wen-Da
    Xian, Wei
    STRUCTURES, 2022, 44 : 680 - 697
  • [22] Nonlinear behaviour of eccentrically loaded FR concrete-filled stainless steel tubular columns
    Ellobody, Ehab
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 90 : 1 - 12
  • [23] Recycled concrete-filled steel tubular columns
    Yang, You-Fu
    Han, Lin-Hai
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 1508 - 1515
  • [24] Hysteresis performance of section steel reinforced concrete-filled rectangular stainless steel tubular columns
    Xie, Enpu
    Wang, Yang
    Bao, Yibei
    Huang, Kun
    Zhang, Xianjiang
    SN APPLIED SCIENCES, 2023, 5 (06):
  • [25] Experimental and numerical investigation of concrete-filled stainless steel columns exposed to fire
    Tao, Zhong
    Ghannam, Mohamed
    Song, Tian-Yi
    Han, Lin-Hai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 118 : 120 - 134
  • [26] Experimental residual capacity of steel-reinforced concrete-filled steel tubular stub columns after fire exposure
    Medall, D.
    Ibanez, C.
    Albero, V.
    Espinos, A.
    Romero, M. L.
    THIN-WALLED STRUCTURES, 2023, 189
  • [27] Performance of recycled aggregate concrete-filled square steel tubular columns exposed to fire
    Yang, You-Fu
    Zhang, Lei
    Dai, Xianghe
    ADVANCES IN STRUCTURAL ENGINEERING, 2017, 20 (09) : 1340 - 1356
  • [28] Residual Strength of Concrete-Filled Double-Skin Steel Tubular Stub Columns after Exposure to Fire
    Yu, Xin
    Tao, Zhong
    Han, Lin-Hai
    Uy, Brian
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 483 - 488
  • [29] Post-fire bond between the steel tube and concrete in concrete-filled steel tubular columns
    Tao, Zhong
    Han, Lin-Hai
    Uy, Brian
    Chen, Xian
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (03) : 484 - 496
  • [30] Nonlinear analysis of axially loaded circular concrete-filled stainless steel tubular short columns
    Patel, Vipulkumar Ishvarbhai
    Liang, Qing Quan
    Hadi, Muhammad N. S.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 101 : 9 - 18