Performance of concrete-filled stainless steel tubular (CFSST) columns after exposure to fire

被引:30
|
作者
Tan, Qing-Hua [1 ]
Gardner, Leroy [2 ]
Han, Lin-Hai [3 ]
Song, Tian-Yi [4 ]
机构
[1] Natl Univ Def Technol, Coll Aerosp Sci & Engn, Changsha, Peoples R China
[2] Imperial Coll London, Dept Civil & Environm Engn, London, England
[3] Tsinghua Univ, Dept Civil Engn, Beijing, Peoples R China
[4] Beijing Univ Technol, Coll Architecture & Civil Engn, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
Concrete-filled stainless steel tubular (CFSST) columns; Post-fire; Finite element analysis (FEA) modelling; Residual strength; Fire safety engineering; COOLING BEHAVIOR; STUB COLUMNS; DESIGN; STRENGTH;
D O I
10.1016/j.tws.2020.106629
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The post-fire performance of concrete-filled stainless steel tubular (CFSST) columns subjected to an entire loading-fire history, including four characteristic phases: (i) ambient temperature loading, (ii) heating, (iii) cooling with constant external loads, and (iv) post-fire loading, is investigated in this paper. Sequentially coupled thermal-stress analyses are performed using ABAQUS to establish the temperature field and structural response of CFSST columns. To improve the precision of the finite element analysis (FEA) models, the influence of moisture on the thermal conductivity and specific heat of the concrete in the heating and cooling phases is considered by using subroutines. Existing fire and post-fire test data on CFSST columns are used to validate the FEA modelling. Comparisons between FEA and test results indicate that the accuracy of the model is acceptable; the FEA model is then extended to simulate CFSST columns subjected to the four characteristic phases. The behaviour of the CFSST columns during the four characteristic phases is explained by analysis of the temperature distribution, load versus axial deformation relations, failure modes and internal force redistribution. The excellent post-fire performance of CFSST columns is examined in comparison with traditional concrete-filled carbon steel tubular (CFST) columns with the same total cross-sectional area. The residual strength index is studied with respect to a series of parametric analyses. It is found that the residual strength of CFSST columns is higher than that of CFST columns after the same fire exposure, and that the diameter of the stainless steel tube, slenderness, heating time ratio and load ratio have a significant influence on the residual strength index.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Fire performance of steel reinforced concrete-filled stainless steel tubular (CFSST) columns with square cross-sections
    Tan, Qing-Hua
    Gardner, Leroy
    Han, Lin-Hai
    Song, Tian-Yi
    THIN-WALLED STRUCTURES, 2019, 143
  • [2] Analysis of concrete-filled steel tubular columns after fire exposure
    Ibanez, C.
    Bisby, L.
    Rush, D.
    Romero, M. L.
    Hospitaler, A.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 795 - 802
  • [3] Cyclic performance of repaired concrete-filled steel tubular columns after exposure to fire
    Han, Lin-Hai
    Lin, Xiao-Kang
    Wang, Yong Chang
    THIN-WALLED STRUCTURES, 2006, 44 (10) : 1063 - 1076
  • [4] ANALYTICAL BEHAVIOUR OF CONCRETE-FILLED DOUBLE SKIN STEEL TUBULAR STUB COLUMNS AFTER EXPOSURE TO FIRE
    Yu, Xin
    Tao, Zhong
    Han, Lin-Hai
    Uy, Brian
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 2268 - 2273
  • [5] Performance of concrete filled stainless steel tubular (CFSST) columns and joints: Summary of recent research
    Han, Lin-Hai
    Xu, Chuan-Yang
    Tao, Zhong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 152 : 117 - 131
  • [6] Fire performance of concrete filled stainless steel tubular columns
    Han, Lin-Hai
    Chen, Feng
    Liao, Fei-Yu
    Tao, Zhong
    Uy, Brian
    ENGINEERING STRUCTURES, 2013, 56 : 165 - 181
  • [7] Fire performance on steel-reinforced concrete-filled steel tubular columns with fire protection
    Mao, Wen-Jing
    Wang, Wen-Da
    Zhou, Kan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 199
  • [8] Tests on plain and steel fiber concrete-filled stainless steel tubular columns
    Tokgoz, Serkan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 114 : 129 - 135
  • [9] Overview of Research Progress for Concrete-filled Steel Tubular Columns after Exposure to Fire
    Pan, Yanchong
    Wang, Guohui
    Xiang, Kai
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING III, PT 1, 2014, 638-640 : 197 - 201
  • [10] Cyclic behaviours of concrete-filled steel tubular columns with pre-load after exposure to fire
    Huo, Jingsi
    Zeng, Xiang
    Xiao, Yan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (04) : 727 - 739