Two-compartment modeling and dynamics of top-sprayed fluidized bed granulator

被引:28
|
作者
Kaur, Gurmeet [1 ,4 ]
Singh, Mehakpreet [1 ,4 ]
Matsoukas, Themis [2 ]
Kumar, Jitendra [1 ]
De Beer, Thomas [3 ]
Nopens, Ingmar [4 ]
机构
[1] Indian Inst Technol Kharagpur, Dept Math, Kharagpur 721302, W Bengal, India
[2] Penn State Univ, Dept Chem Engn, 8H Thomas, University Pk, PA 16802 USA
[3] Univ Ghent, Fac Pharmaceut Sci, Dept Pharmaceut Anal, Pharmaceut Proc Analyt Technol, B-9000 Ghent, Belgium
[4] Univ Ghent, Fac Biosci Engn, Dept Math Modelling Stat & Bioinformat, BIOMATH, B-9000 Ghent, Belgium
关键词
Population balance equation; Sprayed Fluidized Bed Granulator; Compartmental modeling; Finite volume scheme; Monte Carlo method; POPULATION BALANCE MODEL; MONTE-CARLO-SIMULATION; AGGREGATION; PARTICLES; GROWTH; SCHEME;
D O I
10.1016/j.apm.2018.11.028
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A top Spray Fluidized Bed Granulator (SFBG) is being modeled and analyzed with the help of population balance equation (PBE) and analytical as well as numerical results. The mathematical model for SFBG is derived using the concept of compartment modeling. The granulator is divided into two compartments, a wet compartment in which aggregation is the dominant process, and a dry compartment that is dominated by breakage. A new discretization is given to solve the model which is based on the idea of conserving the important properties of the system. The numerical results of the moments derived by the new discretization are validated against the developed exact results for different combinations of the aggregation and breakage kernels. The model is also tested for physical tractable kernel and the numerical results are authenticated with the results of constant volume Monte Carlo. The two-compartment model is shown to behave dynamically in a distinctly different manner to the simpler one-compartment model. The most critical parameter is the exchange flow between the compartments. When the characteristic time for this flow is low relative to the rates of aggregation and breakage, the effect of breakage is amplified disproportionally relative to breakage, and whereas the single-compartment granulator always reaches steady state between the rates of aggregation and breakage, the two-compartment model may, under some conditions, lead to continuously decreasing size under the dominance of breakage. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:267 / 280
页数:14
相关论文
共 50 条
  • [41] FLOW MODELING OF A FLUIDIZED BED REACTOR USING COMPUTATIONAL FLUID DYNAMICS
    Hassan, Md Mehadi
    Rahman, Kazi Moshiur
    INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2021, 48 (05) : 41 - 51
  • [42] Epinephrine effects on insulin-glucose dynamics: the labeled IVGTT two-compartment minimal model approach
    Vicini, P
    Avogaro, A
    Spilker, ME
    Gallo, A
    Cobelli, C
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2002, 283 (01): : E78 - E84
  • [43] Metal artifact reduction (MAR) based on two-compartment physical modeling: evaluation in patients with hip implants
    Boos, Johannes
    Sawicki, Lino Morris
    Lanzman, Rotem Shlomo
    Thomas, Christoph
    Aissa, Joel
    Schleich, Christoph
    Heusch, Philipp
    Antoch, Gerald
    Kroepil, Patric
    ACTA RADIOLOGICA, 2017, 58 (01) : 70 - 76
  • [44] Mathematical correlations in two-phase modeling of fluidized bed adsorbers
    Davarpanah, Morteza
    Hashisho, Zaher
    Crompton, David
    Anderson, E. James
    JOURNAL OF HAZARDOUS MATERIALS, 2022, 423
  • [45] Nonlinear modeling of chaotic dynamics in a circulating fluidized bed by an artificial neural network
    Nakajima, Y
    Kikuchi, R
    Kuramoto, K
    Tsutsumi, A
    Otawara, K
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2001, 34 (02) : 107 - 113
  • [46] Insights in Steam Reforming of Glycerol in a Fluidized Bed by Computational Fluid Dynamics Modeling
    Wang, Shuai
    Song, Xiaojiao
    Chen, Juhui
    Wang, Qi
    Lu, Huilin
    ENERGY & FUELS, 2016, 30 (10) : 8335 - 8342
  • [47] Computational fluid dynamics and electrostatic modeling of polymerization fluidized-bed reactors
    Rokkam, Ram G.
    Fox, Rodney O.
    Muhle, Michael E.
    POWDER TECHNOLOGY, 2010, 203 (02) : 109 - 124
  • [48] Three-compartment (3C) pharmacokinetic modeling is more accurate than two-compartment (2C) modeling of myocardial fibrosis gadolinium kinetics
    James W Goldfarb
    Wenguo Zhao
    Jing Han
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [49] Granule size distribution for a multi-chamber fluidized-bed melt granulator: Modeling and validation using process measurement data
    Bertin, Diego E.
    Cotabarren, Ivana
    Pina, Juliana
    Bucala, Veronica
    CHEMICAL ENGINEERING SCIENCE, 2013, 104 : 319 - 329
  • [50] Bubble dynamics in a two-dimensional gas-solid fluidized bed
    Hong, Ruoyu
    Ren, Zhiqiang
    Ding, Jianmin
    Kawaji, M.
    Li, Hongzhong
    CHINA PARTICUOLOGY, 2007, 5 (04): : 284 - 294