Lower touch sensibility in the extremities of healthy Indians: further deterioration with age

被引:10
作者
Jain, Suman [1 ]
Muzzafarullah, Syed [1 ]
Peri, Sundaresh [1 ]
Ellanti, Ramesh [1 ]
Moorthy, Krishna [1 ]
Nath, Indira [1 ]
机构
[1] LEPRA Soc, Blue Peter Res Ctr, Clin & Epidemiol Div, Hyderabad 501301, Andhra Pradesh, India
关键词
aging; neuropathy screening; peripheral nerves; touch sensibility;
D O I
10.1111/j.1529-8027.2008.00157.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Touch sensibility testing is a cost-effective, psychophysical measure of peripheral nerve function and impairment. However, there is limited information regarding the natural variability in touch sensibility across different populations and different age groups. We studied 568 healthy Indian volunteers without any clinical evidence of peripheral nerve disease. Touch sensibility was evaluated bilaterally in palms, feet, and heels, using Semmes-Weinstein monofilaments, with target forces ranging from 0.008 to 300 g. No differences were observed between the right and the left limbs. The lowest target force detected ranged from 0.4 to 2 g in the palms and 1.4 to 15 g in the feet. These values showed further increase with age. Women compared with men had higher sensibility in the palms in most age groups. Touch sensibility thresholds recorded in a large group of Indians were higher than that reported in other populations. These findings have clinical implications for the diagnosis of early nerve impairment in the elderly and in disease states drawing attention to geographic variations in touch sensation.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 38 条
[1]  
Anderson AM, 1999, LEPROSY REV, V70, P305
[2]   Choosing a practical screening instrument to identify patients at risk for diabetic foot ulceration [J].
Armstrong, DG ;
Lavery, LA ;
Vela, SA ;
Quebedeaux, TL ;
Fleischli, JG .
ARCHIVES OF INTERNAL MEDICINE, 1998, 158 (03) :289-292
[3]  
Bell-Krotoski J A, 1995, J Hand Ther, V8, P155
[4]   THE REPEATABILITY OF TESTING WITH SEMMES-WEINSTEIN MONOFILAMENTS [J].
BELLKROTOSKI, J ;
TOMANCIK, E .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1987, 12A (01) :155-161
[5]  
Birke JA, 2000, INT J LEPROSY, V68, P291
[6]  
BOSCHEINENMORRI. J, 2001, ASSESSMENT HAND FUNA, P7
[7]  
BUHROO AM, 2003, JPMR, V14, P27
[8]   QUANTITATIVE ASSESSMENT OF CUTANEOUS SENSORY FUNCTION IN SUBJECTS WITH NEUROLOGIC DISEASE [J].
CONOMY, JP ;
BARNES, KL .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 1976, 30 (2-3) :221-235
[9]   A 4, 2, AND 1 STEPPING ALGORITHM FOR QUICK AND ACCURATE ESTIMATION OF CUTANEOUS SENSATION THRESHOLD [J].
DYCK, PJ ;
OBRIEN, PC ;
KOSANKE, JL ;
GILLEN, DA ;
KARNES, JL .
NEUROLOGY, 1993, 43 (08) :1508-1512
[10]  
Frykberg Robert G, 2006, J Foot Ankle Surg, V45, pS1