Frame-based and robot-assisted insular stereo-electroencephalography via an anterior or posterior oblique approach

被引:27
作者
Machetanz, Kathrin [1 ,2 ]
Grimm, Florian [1 ,2 ]
Wuttke, Thomas, V [1 ,3 ]
Kegele, Josua [3 ]
Lerche, Holger [3 ]
Tatagiba, Marcos [1 ]
Rona, Sabine [1 ]
Gharabaghi, Alireza [1 ,2 ]
Honegger, Juergen [1 ]
Naros, Georgios [1 ,2 ]
机构
[1] Eberhardt Karls Univ, Dept Neurosurg, Tubingen, Germany
[2] Eberhardt Karls Univ, Div Funct & Restorat Neurosurg, Dept Neurosurg, Tubingen, Germany
[3] Eberhardt Karls Univ, Dept Epileptol, Tubingen, Germany
关键词
frameless stereotactic surgery; insular epilepsy; accuracy; robot-assisted surgery; stereo-electroencephalography; DEPTH ELECTRODES; REGISTRATION; ACCURACY; CORTEX; LOBE; IMPLANTATION; SURGERY; ANATOMY; SAFETY;
D O I
10.3171/2020.10.JNS201843
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE There is an increasing interest in stereo-electroencephalography (SEEG) for invasive evaluation of insular epilepsy. The implantation of insular SEEG electrodes, however, is still challenging due to the anatomical location and complex functional segmentation in both an anteroposterior and ventrodorsal (i.e., superoinferior) direction. While the orthogonal approach (OA) is the shortest trajectory to the insula, it might insufficiently cover these networks. In contrast, the anterior approach (AOA) or posterior oblique approach (POA) has the potential for full insular coverage, with fewer electrodes bearing a risk of being more inaccurate due to the longer trajectory. Here, the authors evaluated the implantation accuracy and the detection of epilepsy-related SEEG activity with AOA and POA insular trajectories. METHODS This retrospective study evaluated the accuracy of 220 SEEG electrodes in 27 patients. Twelve patients underwent a stereotactic frame-based procedure (frame group), and 15 patients underwent a frameless robot-assisted surgery (robot group). In total, 55 insular electrodes were implanted using the AOA or POA considering the insular anteroposterior and ventrodorsal functional organization. The entry point error (EPE) and target point error (TPE) were related to the implantation technique (frame vs robot), the length of the trajectory, and the location of the target (insular vs noninsular). Finally, the spatial distribution of epilepsy-related SEEG activity within the insula is described. RESULTS There were no significant differences in EPE (mean 0.9 +/- 0.6 for the nonsinsular electrodes and 1.1 +/- 0.7 mm for the insular electrodes) and TPE (1.5 +/- 0.8 and 1.6 +/- 0.9 mm, respectively), although the length of trajectories differed significantly (34.1 +/- 10.9 and 70.1 +/- 9.0 mm, repsectively). There was a significantly larger EPE in the frame group than in the robot group (1.5 +/- 0.6 vs 0.7 +/- 0.5 mm). However, there was no group difference in the TPE (1.5 +/- 0.8 vs 1.6 +/- 0.8 mm). Epilepsy-related SEEG activity was detected in 42% (23/55) of the insular electrodes. Spatial distribution of this activity showed a clustering in both anteroposterior and ventrodorsal directions. In purely insular onset cases, subsequent insular lesionectomy resulted in a good seizure outcome. CONCLUSIONS The implantation of insular electrodes via the AOA or POA is safe and efficient for SEEG implantation covering both anteroposterior and ventrodorsal functional organization with few electrodes. In this series, there was no decrease in accuracy due to the longer trajectory of insular SEEG electrodes in comparison with noninsular SEEG electrodes. The results of frame-based and robot-assisted implantations were comparable.
引用
收藏
页码:1477 / 1486
页数:10
相关论文
共 45 条
  • [1] Afif A, 2008, Neurosurgery, V62, pONS471
  • [2] Anatomo-functional organization of the insular cortex in epileptic humans: Study using intracerebral electrical stimulation
    Afif, Afif
    Minotti, Lorella
    Benabid, Alim-Louis
    Kahane, Philippe
    Hoffmann, Dominique
    [J]. NEUROSURGERY, 2008, 62 (06) : 1420 - 1421
  • [3] Indications, technique, and safety profile of insular stereoelectroencephalography electrode implantation in medically intractable epilepsy
    Alomar, Soha
    Mullin, Jeffrey P.
    Smithason, Saksith
    Gonzalez-Martinez, Jorge
    [J]. JOURNAL OF NEUROSURGERY, 2018, 128 (04) : 1147 - 1157
  • [4] Adverse events related to extraoperative invasive EEG monitoring with subdural grid electrodes: A systematic review and meta-analysis
    Arya, Ravindra
    Mangano, Francesco T.
    Horn, Paul S.
    Holland, Katherine D.
    Rose, Douglas F.
    Glauser, Tracy A.
    [J]. EPILEPSIA, 2013, 54 (05) : 828 - 839
  • [5] Circuitry and functional aspects of the insular lobe in primates including humans
    Augustine, JR
    [J]. BRAIN RESEARCH REVIEWS, 1996, 22 (03) : 229 - 244
  • [6] Symmetric diffeomorphic image registration with cross-correlation: Evaluating automated labeling of elderly and neurodegenerative brain
    Avants, B. B.
    Epstein, C. L.
    Grossman, M.
    Gee, J. C.
    [J]. MEDICAL IMAGE ANALYSIS, 2008, 12 (01) : 26 - 41
  • [7] Combined EEG/MEG Can Outperform Single Modality EEG or MEG Source Reconstruction in Presurgical Epilepsy Diagnosis
    Aydin, Uemit
    Vorwerk, Johannes
    Duempelmann, Matthias
    Kuepper, Philipp
    Kugel, Harald
    Heers, Marcel
    Wellmer, Joerg
    Kellinghaus, Christoph
    Haueisen, Jens
    Rampp, Stefan
    Stefan, Hermann
    Wolters, Carsten H.
    [J]. PLOS ONE, 2015, 10 (03):
  • [8] Advances in intracranial monitoring
    Blount, Jeffrey P.
    Cormier, Jason
    Kim, Hyunmi
    Kankirawatana, Pongkiat
    Riley, Kristen O.
    Knowlton, Robert C.
    [J]. NEUROSURGICAL FOCUS, 2008, 25 (03)
  • [9] The comparative accuracy of the ROSA stereotactic robot across a wide range of clinical applications and registration techniques
    Brandmeir N.J.
    Savaliya S.
    Rohatgi P.
    Sather M.
    [J]. Journal of Robotic Surgery, 2018, 12 (1) : 157 - 163
  • [10] A new tool for touch-free patient registration for robot-assisted intracranial surgery: application accuracy from a phantom study and a retrospective surgical series
    Cardinale, Francesco
    Rizzi, Michele
    d'Orio, Piergiorgio
    Casaceli, Giuseppe
    Arnulfo, Gabriele
    Narizzano, Massimo
    Scorza, Davide
    De Momi, Elena
    Nichelatti, Michele
    Redaelli, Daniela
    Sberna, Maurizio
    Moscato, Alessio
    Castana, Laura
    [J]. NEUROSURGICAL FOCUS, 2017, 42 (05)