Investigation on the thermal performance of a novel spray tower with upward spraying and downward gas flow

被引:30
作者
Cui, Haijiao [1 ]
Li, Nianping [1 ]
Peng, Jinqing [1 ]
Yin, Rongxin [1 ,2 ]
Li, Jingming [1 ]
Wu, Zhibin [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410081, Hunan, Peoples R China
[2] Lawrence Berkeley Natl Lab, Energy Storage & Distributed Resources Div, Berkeley, CA USA
关键词
Direct-contact heat and mass transfer; Spray systems; Reversibly used cooling towers; Particulate removal; Heat pumps; SHOWER COOLING-TOWER; NUMERICAL-SIMULATION; CO2; ABSORPTION; WATER SPRAY; FLUE-GAS; LIQUID; AIR; ENERGY; TEMPERATURE; SYSTEM;
D O I
10.1016/j.apenergy.2018.09.123
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the design and evaluation of a novel spray tower which called the reversibly used cooling tower with upward spraying and downward gas flow (RUCT-UD). Unlike conventional spray towers, RUCT-UD has no high-resistance drift eliminator and no restriction on the minimum droplet diameter, which gives it the potential to achieve better performance of heat and mass transfer and particle scavenging. A mathematical model was developed and validated by field experiments. This model is highly efficient in calculation due to the simultaneous consideration of rising and falling droplets. Using the model, the heat and mass transfer characteristics were investigated by, a parametric study, which provides a theoretical basis for the tower design. After that, the performance of RUCT-UD was compared with that of other spray-type RUCTs. Results show that RUCT-UD is 45% shorter than RUCT-UU (the reversibly used cooling tower with upward spraying and upward gas flow) and RUCT-DU (the reversibly used cooling tower with downward spraying and upward gas flow), meanwhile it could realize a high thermal performance like RUCT-UU. The particle collection efficiency of PM2.5 for RUCT-UD is 75.9%, which is higher than that of RUCT-UU (48.9%) and that of RUCT-DU (61.1%). The configuration of the proposed RUCT-UD might be applied to other spray towers for the performance improvement.
引用
收藏
页码:12 / 21
页数:10
相关论文
共 42 条
  • [31] Numerical study of particle collection by single water droplets
    Viswanathan, S
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (11) : 4433 - 4442
  • [32] Experimental study on heat transfer coefficient between air and liquid in the cross-flow heat-source tower
    Wen, Xiantai
    Liang, Caihua
    Zhang, Xiaosong
    [J]. BUILDING AND ENVIRONMENT, 2012, 57 : 205 - 213
  • [33] Wu J, 2005, THEOREITCAL STUDY RE
  • [34] Artificial neural network analysis of the performance characteristics of a reversibly used cooling tower under cross flow conditions for heat pump heating system in winter
    Wu, Jiasheng
    Zhang, Guoqiang
    Zhang, Quan
    Zhou, Jin
    Wang, Yu
    [J]. ENERGY AND BUILDINGS, 2011, 43 (07) : 1685 - 1693
  • [35] Experimental and numerical study on CO2 absorption mass transfer enhancement for a diameter-varying spray tower
    Wu, Xiao M.
    Qin, Zhen
    Yu, Yun S.
    Zhang, Zao X.
    [J]. APPLIED ENERGY, 2018, 225 : 367 - 379
  • [36] Numerical simulation of aqueous ammonia-based CO2 absorption in a sprayer tower: An integrated model combining gas-liquid hydrodynamics and chemistry
    Xu, Yin
    Jin, Baosheng
    Zhao, Yongling
    Hu, Eric J.
    Chen, Xiaole
    Li, Xiaochuan
    [J]. APPLIED ENERGY, 2018, 211 : 318 - 333
  • [37] Experimental and theoretical studies on air humidification by a water spray at elevated pressure
    Xu, Zhen
    Xiao, Yunhan
    Wang, Yue
    [J]. APPLIED THERMAL ENGINEERING, 2007, 27 (14-15) : 2549 - 2558
  • [38] Performance investigation on the ultrasonic atomization liquid desiccant regeneration system
    Yang, Zili
    Zhang, Kaisheng
    Hwang, Yunho
    Lian, Zhiwei
    [J]. APPLIED ENERGY, 2016, 171 : 12 - 25
  • [39] Improvement of the ultrasonic atomization liquid desiccant dehumidification system
    Yang, Zili
    Zhang, Kaisheng
    Yang, Menghao
    Lian, Zhiwei
    [J]. ENERGY AND BUILDINGS, 2014, 85 : 145 - 154
  • [40] Comparative efficiency evaluations of four types of cooling tower drift eliminator, by numerical investigation
    Zamora, B.
    Kaiser, A. S.
    [J]. CHEMICAL ENGINEERING SCIENCE, 2011, 66 (06) : 1232 - 1245