Experimental study on wedge-bonded anchors for CFRP tendons under cyclic loading

被引:9
作者
Xie, Gui-hua [1 ,2 ]
Bian, Yu-long [1 ]
Feng, Qian-hong [1 ]
Wang, C. M. [2 ]
Liu, Rong-gui [1 ]
机构
[1] Jiangsu Univ, Fac Civil Engn & Mech, Dept Civil Engn, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Univ Queensland, Sch Civil Engn, St Lucia, Qld 4072, Australia
基金
中国国家自然科学基金;
关键词
Wedge-bonded anchor; CFRP tendon; Fatigue damage; Stress level; Stress ratio; COMPOSITE ANCHORS; FATIGUE BEHAVIOR; RC BEAMS; FRP; PERFORMANCE; STEEL; SYSTEM; OPTIMIZATION; BRIDGES;
D O I
10.1016/j.conbuildmat.2019.117599
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper is concerned with an experimental study on a wedge-bonded anchor for carbon fibre reinforced polymer (CFRP) tendons under cyclic loading. The adhesive reinforced by quartz sand was tested to be superior as a bonding material for the anchor when compared to the adhesive reinforced by ferrous powder or aluminate powder. Structural responses of the wedge-bonded anchor under cyclic loading were analyzed with regard to system slip, sleeve strain, temperature rise in the anchor zone and residual tensile load capacity. The results indicate that the maximum stress level and stress ratio influence significantly the fatigue performance of wedge-bonded anchors. A cyclic loading with a high stress ratio and low stress level is beneficial due to the synergetic effect of the components in the wedge-bonded anchors. However, enhancing the stress level or lowering the stress ratio leads to a larger slip, greater damage and more loading cycles are needed for the stabilization of wedge-bonded anchors. When the stress ratio exceeds 0.4 and the maximum stress is less than 0.5, damage in anchor zone is initiated and developed in the early stage of cyclic loading, but the anchor becomes stable finally. A large decrease in stress ratio may result in a continuous development of microstructural damage and the eventual failure of the anchor, accompanied by continuously increasing energy dissipation under cyclic loading. The axial strain of sleeve in a wedge-bonded anchor is influenced by the extent of damage evolution and the synergetic effect of anchor assemblies: thereby resulting in different trends in sleeve strain-cycle curves under different stress ratios and stress levels. The temperature rise may be pronounced at a loading frequency of 10 Hz or less, which is related to the stress ratio. The damage development in the wedge-bonded anchor with an infinite fatigue life was analyzed. The mechanism of fatigue damage in wedge-bonded anchors is different from that of adhesively bonded anchors. Moreover, wedge-bonded anchors have a stronger resistance against fatigue due to the interaction between the wedges and the other assemblies. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Experimental and numerical study of an elliptical roller damper under cyclic loading
    Sadeghi, Hadis Vakili
    Fanaie, Nader
    Latifi, Majid
    STRUCTURES, 2025, 71
  • [32] Experimental Study of Rectangular RC Columns Strengthened with CFRP Composites under Eccentric Loading
    Sadeghian, Pedram
    Rahai, Ali R.
    Ehsani, Mohammad R.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (04) : 443 - 450
  • [33] Experimental study on the bond behavior of the CFRP-steel interface under rapid loading
    Pang, Yuyang
    Wu, Gang
    Wang, Haitao
    Gao, Danying
    Zhang, Pu
    THIN-WALLED STRUCTURES, 2021, 159 (159)
  • [34] Experimental study of fatigue behaviour of CFRP-to-concrete bonded joints employing the EBROG strengthening technique
    Khorasani, Mehdi
    Muciaccia, Giovanni
    Mostofinejad, Davood
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 435
  • [35] Experimental and theoretical research on bond performance between CFRP bar and concrete under monotonic and reversed cyclic loading
    Zhao, Jun
    Li, Xiaopeng
    Zhang, Xiangcheng
    ENGINEERING STRUCTURES, 2021, 246
  • [36] Experimental Study on Shear Performance of Concrete Beams Reinforced with Externally Unbonded Prestressed CFRP Tendons
    Qi, Hetao
    Jiang, Haozhe
    Wang, Bing
    Zhuge, Ping
    FIBERS, 2024, 12 (03)
  • [37] Structural behaviour of CFRP strengthened beam-column connections under monotonic and cyclic loading
    Tafsirojjaman, T.
    Fawzia, Sabrina
    Thambiratnam, David P.
    STRUCTURES, 2021, 33 : 2689 - 2699
  • [38] RC Slabs Strengthened with Prestressed and Gradually Anchored CFRP Strips under Monotonic and Cyclic Loading
    Kotynia, Renata
    Walendziak, Radoslaw
    Stoecklin, Iwan
    Meier, Urs
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (02) : 168 - 180
  • [39] Mechanical properties of concrete beams reinforced with CFRP prestressed prisms under reverse cyclic loading
    Liang, Jiongfeng
    Yu, Deng
    Wang, Jianbao
    Yi, Pinghua
    EARTHQUAKES AND STRUCTURES, 2016, 11 (02) : 315 - 326
  • [40] Experimental study on precracked RC beams strengthened with externally bonded CFRP sheets
    Dong, Jiangfeng
    Wang, Qingyuan
    Zhu, Yanmei
    ADVANCES IN COMPOSITES, PTS 1 AND 2, 2011, 150-151 : 842 - 846